Literature DB >> 7578782

Osseointegration of Brånemark fixtures using a single-step operating technique. A preliminary prospective one-year study in the edentulous mandible.

J P Bernard1, U C Belser, J P Martinet, S A Borgis.   

Abstract

The aim of the present prospective clinical study was to analyze the feasibility of inserting Brånemark fixtures according to a one-stage procedure including transmucosal healing and to subsequently evaluate the predictability of osseointegration as well as the potential of such implants for stabilizing complete overdentures in the edentulous mandible. Five patients (2 women, 3 men), completely edentulous in the mandible and with a mean age of 60 years, volunteered for this study. Two fixtures of various length (10-20 mm) and 3.75 mm in diameter were inserted in the lower canine regions. A standard surgical procedure including a midcrestal incision was used. After the placement of the fixtures, healing abutments, which are normally used during second-stage surgery, were inserted instead of the usual cover screws. Three months after implant placement a clinical and radiographic examination was performed to confirm the presence or absence of osseointegration of the fixtures prior to exchanging the healing abutments with the spherical attachments. Finally, different clinical (Plaque Index, Bleeding Index, probing depth, Periotest mobility) and radiographic (bone loss, peri-implant radiolucency) parameters were recorded 9 months after loading of the fixtures by means of a complete mandibular overdenture, retained by two ball attachments in the canine regions. All fixtures were perfectly stable (mean Periotest values of -2) and presented favorable peri-mplant soft tissue conditions, and no patient was complaining about any particular symptom. As far as retention and stability of their implant supported overdenture was concerned, the participants without exception considered the therapeutic result as being perfectly adequate.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 7578782     DOI: 10.1034/j.1600-0501.1995.060208.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  Biomimetic treatment on dental implants for short-term bone regeneration.

Authors:  Francisco Javier Gil; Norberto Manzanares; Armando Badet; Conrado Aparicio; Maria-Pau Ginebra
Journal:  Clin Oral Investig       Date:  2013-03-08       Impact factor: 3.573

2.  Effect of loading time on the survival rate of anodic oxidized implants: prospective multicenter study.

Authors:  Seok-Gyu Kim; Pil-Young Yun; Hyun-Sik Park; June-Sung Shim; Jung-Won Hwang; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2012-02-29       Impact factor: 1.904

3.  Biomechanics and load resistance of short dental implants: a review of the literature.

Authors:  Istabrak Hasan; Christoph Bourauel; Torsten Mundt; Friedhelm Heinemann
Journal:  ISRN Dent       Date:  2013-05-08

4.  Comparative evaluation of the influence of immediate versus delayed loading protocols of dental implants: A radiographic and clinical study.

Authors:  Amrit Tandan; Viram Upadhyaya; Mohit Raghuvanshi
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.