Literature DB >> 22430480

KERMA ratios in pediatric CT dosimetry.

Walter Huda1, Kent M Ogden, Robert L Lavallee, Marsha L Roskopf, Ernest M Scalzetti.   

Abstract

BACKGROUND: Patient organ doses may be estimated from CTDI values. More accurate estimates may be obtained by measuring KERMA (Kinetic Energy Released in Matter) in anthropomorphic phantoms and referencing these values to free-in-air X-ray intensity.
OBJECTIVE: To measure KERMA ratios (R(K)) in pediatric phantoms at CT. MATERIALS &
METHODS: CT scans produce an air KERMA K in a phantom and an air KERMA K(CT) at isocenter. KERMA ratios (R(K)) are defined as (K/K(CT)), measured using TLD chips in phantoms representing newborns to 10-year-olds.
RESULTS: R(K) in the newborn is approximately constant. For the other phantoms, there is a peak R(K) value in the neck. The median R(K) values for the GE scanner at 120 kV were 0.92, 0.83, 0.77 and 0.76 for newborns, 1-year-olds, 5-year-olds and 10-year-olds, respectively. Organ R(K) values were 0.91 ± 0.04, 0.84 ± 0.07, 0.74 ± 0.09 and 0.72 ± 0.10 in newborns, 1-year-olds, 5-year-olds and 10-year-olds, respectively. At 120 kV, a Siemens Sensation 16 scanner had R(K) values 5% higher than those of the GE LightSpeed Ultra.
CONCLUSION: KERMA ratios may be combined with air KERMA measurements at the isocenter to estimate organ doses in pediatric CT patients.

Entities:  

Mesh:

Year:  2012        PMID: 22430480     DOI: 10.1007/s00247-011-2336-4

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  19 in total

1.  Managing patient dose in computed tomography. A report of the International Commission on Radiological Protection.

Authors: 
Journal:  Ann ICRP       Date:  2000

2.  Pediatric phantoms.

Authors:  Vladimir Varchena
Journal:  Pediatr Radiol       Date:  2002-03-06

3.  The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103.

Authors: 
Journal:  Ann ICRP       Date:  2007

4.  Converting dose-length product to effective dose at CT.

Authors:  Walter Huda; Kent M Ogden; Mohammad R Khorasani
Journal:  Radiology       Date:  2008-09       Impact factor: 11.105

5.  Dose exposure of patients undergoing comprehensive stroke imaging by multidetector-row CT: comparison of 320-detector row and 64-detector row CT scanners.

Authors:  S Diekmann; E Siebert; R Juran; M Roll; W Deeg; H-C Bauknecht; F Diekmann; R Klingebiel; G Bohner
Journal:  AJNR Am J Neuroradiol       Date:  2010-01-28       Impact factor: 3.825

6.  A PC program for estimating organ dose and effective dose values in computed tomography.

Authors:  W A Kalender; B Schmidt; M Zankl; M Schmidt
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

7.  ICRP Publication 105. Radiation protection in medicine.

Authors: 
Journal:  Ann ICRP       Date:  2007

Review 8.  Radiation biology for pediatric radiologists.

Authors:  Eric J Hall
Journal:  Pediatr Radiol       Date:  2008-12-16

9.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007

10.  Assessment of organ absorbed doses and estimation of effective doses from pediatric anthropomorphic phantom measurements for multi-detector row CT with and without automatic exposure control.

Authors:  Hervé J Brisse; Magalie Robilliard; Alexia Savignoni; Noelle Pierrat; Geneviève Gaboriaud; Yann De Rycke; Sylvia Neuenschwander; Bernard Aubert; Jean-Claude Rosenwald
Journal:  Health Phys       Date:  2009-10       Impact factor: 1.316

View more
  1 in total

1.  KERMA ratios vs. SSDE: is one better at estimating pediatric CT radiation doses?

Authors:  Keith J Strauss
Journal:  Pediatr Radiol       Date:  2012-03-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.