Literature DB >> 22421269

Null-space function estimation for the interior problem.

Gengsheng L Zeng1, Grant T Gullberg.   

Abstract

In single-photon emission computed tomography (SPECT), projection data can be truncated when the camera's field of view is smaller than the object to be imaged. Using truncated projections to reconstruct a region of interest (ROI) is a reality we must face if small detectors are used. The truncated data result in an underdetermined system of imaging equations, which may lead to non-unique solutions. Data sampling and photon attenuation may also affect the solution uniqueness and stability. The uniqueness of the solutions in the ROI can be investigated by studying the null-space functions in the ROI. This paper uses an iterative algorithm to estimate the null-space image, to determine the sampling conditions under which a stable ROI reconstruction is possible with truncated data and to investigate whether attenuation can influence the ROI reconstruction bias. This iterative algorithm is validated by the singular value decomposition method. We show that if the ROI is sufficiently sampled, the null-space image is close to zero inside the ROI, and any almost-zero offset is insignificant in SPECT, because the noise is a much more dominating degradation factor.

Entities:  

Mesh:

Year:  2012        PMID: 22421269      PMCID: PMC3358924          DOI: 10.1088/0031-9155/57/7/1873

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  20 in total

1.  SPECT region of interest reconstruction with truncated transmission and emission data.

Authors:  Gengsheng L Zeng; Grant T Gullberg
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Computed tomographic imaging within nuclear cardiology.

Authors: 
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

3.  Image reconstruction in peripheral and central regions-of-interest and data redundancy.

Authors:  Xiaochuan Pan; Yu Zou; Dan Xia
Journal:  Med Phys       Date:  2005-03       Impact factor: 4.071

4.  Closed-form kinetic parameter estimation solution to the truncated data problem.

Authors:  Gengsheng L Zeng; Grant T Gullberg; Dan J Kadrmas
Journal:  Phys Med Biol       Date:  2010-11-19       Impact factor: 3.609

5.  Tiny a priori knowledge solves the interior problem in computed tomography.

Authors:  Hiroyuki Kudo; Matias Courdurier; Frédéric Noo; Michel Defrise
Journal:  Phys Med Biol       Date:  2008-04-09       Impact factor: 3.609

6.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Authors:  Guang-Hong Chen; Jie Tang; Shuai Leng
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

7.  The effects of a finite number of projection angles and finite lateral sampling of projections on the propagation of statistical errors in transverse section reconstruction.

Authors:  R H Huesman
Journal:  Phys Med Biol       Date:  1977-05       Impact factor: 3.609

8.  SVD for imaging systems with discrete rotational symmetry.

Authors:  Eric Clarkson; Robin Palit; Matthew A Kupinski
Journal:  Opt Express       Date:  2010-11-22       Impact factor: 3.894

9.  Image reconstruction in circular cone-beam computed tomography by constrained, total-variation minimization.

Authors:  Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2008-08-13       Impact factor: 3.609

10.  Compressed sensing based interior tomography.

Authors:  Hengyong Yu; Ge Wang
Journal:  Phys Med Biol       Date:  2009-04-15       Impact factor: 3.609

View more
  6 in total

1.  On the bias of finite-view interior tomography using piecewise-constant and non-negativity constraints.

Authors:  Gengsheng L Zeng; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2013-02-05       Impact factor: 3.609

2.  The impact of system matrix dimension on small FOV SPECT reconstruction with truncated projections.

Authors:  Chung Chan; Joyoni Dey; Yariv Grobshtein; Jing Wu; Yi-Hwa Liu; Rachel Lampert; Albert J Sinusas; Chi Liu
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

3.  A tailored ML-EM algorithm for reconstruction of truncated projection data using few view angles.

Authors:  Yanfei Mao; Gengsheng L Zeng
Journal:  Phys Med Biol       Date:  2013-05-20       Impact factor: 3.609

Review 4.  The meaning of interior tomography.

Authors:  Ge Wang; Hengyong Yu
Journal:  Phys Med Biol       Date:  2013-08-02       Impact factor: 3.609

5.  Design of Acquisition Schemes and Setup Geometry for Anisotropic X-ray Dark-Field Tomography (AXDT).

Authors:  Y Sharma; F Schaff; M Wieczorek; F Pfeiffer; T Lasser
Journal:  Sci Rep       Date:  2017-06-09       Impact factor: 4.379

6.  Fast acquisition protocol for X-ray scattering tensor tomography.

Authors:  Jisoo Kim; Matias Kagias; Federica Marone; Zhitian Shi; Marco Stampanoni
Journal:  Sci Rep       Date:  2021-11-29       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.