Literature DB >> 23380877

On the bias of finite-view interior tomography using piecewise-constant and non-negativity constraints.

Gengsheng L Zeng1, Grant T Gullberg.   

Abstract

It has been widely believed that the non-negativity and the piecewise-constant constraints guarantee a unique solution to an interior tomographic problem. This letter points out that if the number of views is finite, the non-negativity and the piecewise-constant constraints do not guarantee a unique solution to an interior tomographic problem and the reconstruction could be biased by a constant polygon.

Entities:  

Mesh:

Year:  2013        PMID: 23380877      PMCID: PMC3584581          DOI: 10.1088/0031-9155/58/5/L13

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Image reconstruction in peripheral and central regions-of-interest and data redundancy.

Authors:  Xiaochuan Pan; Yu Zou; Dan Xia
Journal:  Med Phys       Date:  2005-03       Impact factor: 4.071

2.  Tiny a priori knowledge solves the interior problem in computed tomography.

Authors:  Hiroyuki Kudo; Matias Courdurier; Frédéric Noo; Michel Defrise
Journal:  Phys Med Biol       Date:  2008-04-09       Impact factor: 3.609

3.  Supplemental analysis on compressed sensing based interior tomography.

Authors:  Hengyong Yu; Jiansheng Yang; Ming Jiang; Ge Wang
Journal:  Phys Med Biol       Date:  2009-08-28       Impact factor: 3.609

4.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Authors:  Guang-Hong Chen; Jie Tang; Shuai Leng
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

5.  Null-space function estimation for the interior problem.

Authors:  Gengsheng L Zeng; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2012-03-16       Impact factor: 3.609

6.  Compressed sensing based interior tomography.

Authors:  Hengyong Yu; Ge Wang
Journal:  Phys Med Biol       Date:  2009-04-15       Impact factor: 3.609

  6 in total
  2 in total

Review 1.  The meaning of interior tomography.

Authors:  Ge Wang; Hengyong Yu
Journal:  Phys Med Biol       Date:  2013-08-02       Impact factor: 3.609

2.  CT brush and CancerZap!: two video games for computed tomography dose minimization.

Authors:  Graham Alvare; Richard Gordon
Journal:  Theor Biol Med Model       Date:  2015-05-12       Impact factor: 2.432

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.