Literature DB >> 22411784

On the inherent precision of mcDESPOT.

Christopher L Lankford1, Mark D Does.   

Abstract

A statistical analysis of the mcDESPOT protocol for characterizing two exchanging water proton pools--a seven-dimensional problem that fits to multiple flip angle measurements of both spoiled and refocused gradient echoes--is presented. Theoretical calculations of the Cramér-Rao lower bounds of the variance of fitted model parameters were made using a variety of model system parameters, meant to mimic those expected in human white matter. The results, validated by Monte Carlo simulations, indicated that mcDESPOT signals acquired at feasibly attainable signal-to-noise ratios cannot provide parameter estimates with useful levels of precision. Precision can be greatly improved by constraining solutions with a priori model information, although this will generally lead to biased parameter estimates with less specificity. These results indicate that previous, apparently successful applications of mcDESPOT to human white matter may have used data fitting methods that implicitly constrained parameter solutions, or that the two-pool model of white matter may not be sufficient to describe the observed water proton signal in mcDESPOT acquisitions. In either case, mcDESPOT-derived estimates of two-pool model parameters cannot yet be unambiguously related to specific tissue characteristics.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22411784      PMCID: PMC3449046          DOI: 10.1002/mrm.24241

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  28 in total

1.  Characterizing white matter with magnetization transfer and T(2).

Authors:  G J Stanisz; A Kecojevic; M J Bronskill; R M Henkelman
Journal:  Magn Reson Med       Date:  1999-12       Impact factor: 4.668

2.  Rapid acquisition transverse relaxometric imaging.

Authors:  M D Does; J C Gore
Journal:  J Magn Reson       Date:  2000-11       Impact factor: 2.229

3.  Proton relaxation studies of water compartmentalization in a model neurological system.

Authors:  R S Menon; M S Rusinko; P S Allen
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

4.  Practical T2 quantitation for clinical applications.

Authors:  C S Poon; R M Henkelman
Journal:  J Magn Reson Imaging       Date:  1992 Sep-Oct       Impact factor: 4.813

5.  Applications of stimulated echo correction to multicomponent T2 analysis.

Authors:  Thomas Prasloski; Burkhard Mädler; Qing-San Xiang; Alex MacKay; Craig Jones
Journal:  Magn Reson Med       Date:  2011-10-19       Impact factor: 4.668

6.  Water compartments in the myelinated nerve. III. Pulsed NMR results.

Authors:  V Vasilescu; E Katona; V Simplăceanu; D Demco
Journal:  Experientia       Date:  1978-11-15

7.  Measurement of signal intensities in the presence of noise in MR images.

Authors:  R M Henkelman
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

8.  Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.

Authors:  Sean C L Deoni
Journal:  Magn Reson Med       Date:  2010-12-08       Impact factor: 4.668

9.  Effect of intercompartmental water exchange on the apparent myelin water fraction in multiexponential T2 measurements of rat spinal cord.

Authors:  Kevin D Harkins; Adrienne N Dula; Mark D Does
Journal:  Magn Reson Med       Date:  2011-06-28       Impact factor: 4.668

10.  Cholesterol of myelin is the determinant of gray-white contrast in MRI of brain.

Authors:  S H Koenig
Journal:  Magn Reson Med       Date:  1991-08       Impact factor: 4.668

View more
  39 in total

Review 1.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

2.  Myelin volume fraction imaging with MRI.

Authors:  Kathryn L West; Nathaniel D Kelm; Robert P Carson; Daniel F Gochberg; Kevin C Ess; Mark D Does
Journal:  Neuroimage       Date:  2016-12-23       Impact factor: 6.556

3.  Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping.

Authors:  Christopher L Lankford; Mark D Does
Journal:  Magn Reson Med       Date:  2017-04-20       Impact factor: 4.668

4.  Assessment of the myelin water fraction in rodent spinal cord using T2-prepared ultrashort echo time MRI.

Authors:  Tim Klasen; Cornelius Faber
Journal:  MAGMA       Date:  2016-07-09       Impact factor: 2.310

Review 5.  [Computational neuroanatomy and microstructure imaging using magnetic resonance imaging].

Authors:  S Mohammadi; N Weiskopf
Journal:  Nervenarzt       Date:  2017-08       Impact factor: 1.214

Review 6.  Imaging structural and functional brain development in early childhood.

Authors:  John H Gilmore; Rebecca C Knickmeyer; Wei Gao
Journal:  Nat Rev Neurosci       Date:  2018-02-16       Impact factor: 34.870

7.  Optimization of selective inversion recovery magnetization transfer imaging for macromolecular content mapping in the human brain.

Authors:  Richard D Dortch; Francesca Bagnato; Daniel F Gochberg; John C Gore; Seth A Smith
Journal:  Magn Reson Med       Date:  2018-03-24       Impact factor: 4.668

8.  Analysis of mcDESPOT- and CPMG-derived parameter estimates for two-component nonexchanging systems.

Authors:  Mustapha Bouhrara; David A Reiter; Hasan Celik; Kenneth W Fishbein; Richard Kijowski; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-07-03       Impact factor: 4.668

9.  Myelin water fraction estimation using small-tip fast recovery MRI.

Authors:  Steven T Whitaker; Gopal Nataraj; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  Magn Reson Med       Date:  2020-04-12       Impact factor: 4.668

10.  Early Postnatal Myelin Content Estimate of White Matter via T1w/T2w Ratio.

Authors:  Kevin Lee; Marie Cherel; Francois Budin; John Gilmore; Kirsten Zaldarriaga Consing; Jerod Rasmussen; Pathik D Wadhwa; Sonja Entringer; Matthew F Glasser; David C Van Essen; Claudia Buss; Martin Styner
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.