Literature DB >> 21413066

Correction of main and transmit magnetic field (B0 and B1) inhomogeneity effects in multicomponent-driven equilibrium single-pulse observation of T1 and T2.

Sean C L Deoni1.   

Abstract

Multicomponent-driven equilibrium single-component observation of T(1) and T(2) offers a new approach to multiple component relaxation time and myelin water analysis. The method derives two-component relaxation information from spoiled and fully balanced steady-state (SPGR and bSSFP) imaging data acquired over multiple flip angles. Although these steady-state imaging techniques afford rapid acquisition times and high signal-to-noise ratio efficiency, they are also sensitive to main (B(0) ) and transmit (B(1) ) magnetic field inhomogeneities. These effects alter the measured signal from their theoretical values and lead to substantive errors in the derived myelin volume fraction estimates. Here, we incorporate correction techniques to mitigate these effects. DESPOT1-HIFI is used to first calibrate the transmitted flip angles; and B(0) affects are removed through the inclusion of an additional parameter in the multicomponent-driven equilibrium single-component observation of T(1) and T(2) fitting, coupled with the acquisition of multiple phase-cycled bSSFP data. The performance of these correction techniques was evaluated using numerical simulations, demonstrating effective removal of B(0) and B(1)-induced errors in the derived myelin fraction relaxation parameters. The approach was also successfully demonstrated in vivo, with near artifact-free whole-brain, high spatial resolution (1.7 mm × 1.7 mm × 1.7 mm isotropic voxels) myelin water fraction maps acquired in a clinically feasible 16 min.
Copyright © 2010 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2010        PMID: 21413066      PMCID: PMC3777237          DOI: 10.1002/mrm.22685

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Measurement of spin-lattice relaxation times and concentrations in systems with chemical exchange using the one-pulse sequence: breakdown of the Ernst model for partial saturation in nuclear magnetic resonance spectroscopy.

Authors:  R G Spencer; K W Fishbein
Journal:  J Magn Reson       Date:  2000-01       Impact factor: 2.229

2.  Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state.

Authors:  Sean C L Deoni; Brian K Rutt; Terry M Peters
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

3.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

4.  Is multicomponent T2 a good measure of myelin content in peripheral nerve?

Authors:  Stephanie Webb; Catherine A Munro; Rajiv Midha; Greg J Stanisz
Journal:  Magn Reson Med       Date:  2003-04       Impact factor: 4.668

5.  Practical T2 quantitation for clinical applications.

Authors:  C S Poon; R M Henkelman
Journal:  J Magn Reson Imaging       Date:  1992 Sep-Oct       Impact factor: 4.813

6.  Motion-insensitive, steady-state free precession imaging.

Authors:  Y Zur; M L Wood; L J Neuringer
Journal:  Magn Reson Med       Date:  1990-12       Impact factor: 4.668

7.  Multiexponential proton relaxation in model cellular systems.

Authors:  R S Menon; M S Rusinko; P S Allen
Journal:  Magn Reson Med       Date:  1991-08       Impact factor: 4.668

Review 8.  Fast robust automated brain extraction.

Authors:  Stephen M Smith
Journal:  Hum Brain Mapp       Date:  2002-11       Impact factor: 5.038

9.  Gleaning multicomponent T1 and T2 information from steady-state imaging data.

Authors:  Sean C L Deoni; Brian K Rutt; Tarunya Arun; Carlo Pierpaoli; Derek K Jones
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

10.  Three-pool model of white matter.

Authors:  Jack L Lancaster; Trevor Andrews; L Jean Hardies; Stephen Dodd; Peter T Fox
Journal:  J Magn Reson Imaging       Date:  2003-01       Impact factor: 4.813

View more
  63 in total

1.  Incorporation of nonzero echo times in the SPGR and bSSFP signal models used in mcDESPOT.

Authors:  Mustapha Bouhrara; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-09-26       Impact factor: 4.668

2.  Age-dynamic networks and functional correlation for early white matter myelination.

Authors:  Xiongtao Dai; Hans-Georg Müller; Jane-Ling Wang; Sean C L Deoni
Journal:  Brain Struct Funct       Date:  2018-11-03       Impact factor: 3.270

3.  Rapid B1 field mapping at 3 T using the 180° signal null method with extended flip angle.

Authors:  Abinand C Rejimon; Diana Y Lee; Christopher M Bergeron; You Zhuo; Wenshu Qian; Richard G Spencer; Mustapha Bouhrara
Journal:  Magn Reson Imaging       Date:  2018-06-26       Impact factor: 2.546

Review 4.  Studying neuroanatomy using MRI.

Authors:  Jason P Lerch; André J W van der Kouwe; Armin Raznahan; Tomáš Paus; Heidi Johansen-Berg; Karla L Miller; Stephen M Smith; Bruce Fischl; Stamatios N Sotiropoulos
Journal:  Nat Neurosci       Date:  2017-02-23       Impact factor: 24.884

5.  Traveling Slow Oscillations During Sleep: A Marker of Brain Connectivity in Childhood.

Authors:  Salome Kurth; Brady A Riedner; Douglas C Dean; Jonathan O'Muircheartaigh; Reto Huber; Oskar G Jenni; Sean C L Deoni; Monique K LeBourgeois
Journal:  Sleep       Date:  2017-09-01       Impact factor: 5.849

6.  Analysis of mcDESPOT- and CPMG-derived parameter estimates for two-component nonexchanging systems.

Authors:  Mustapha Bouhrara; David A Reiter; Hasan Celik; Kenneth W Fishbein; Richard Kijowski; Richard G Spencer
Journal:  Magn Reson Med       Date:  2015-07-03       Impact factor: 4.668

7.  Simultaneous variable flip angle-actual flip angle imaging method for improved accuracy and precision of three-dimensional T1 and B1 measurements.

Authors:  Samuel A Hurley; Vasily L Yarnykh; Kevin M Johnson; Aaron S Field; Andrew L Alexander; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

Review 8.  Advances in myelin imaging with potential clinical application to pediatric imaging.

Authors:  Heather S Spader; Anna Ellermeier; Jonathan O'Muircheartaigh; Douglas C Dean; Holly Dirks; Jerrold L Boxerman; G Rees Cosgrove; Sean C L Deoni
Journal:  Neurosurg Focus       Date:  2013-04       Impact factor: 4.047

9.  Myelin water fraction estimation using small-tip fast recovery MRI.

Authors:  Steven T Whitaker; Gopal Nataraj; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  Magn Reson Med       Date:  2020-04-12       Impact factor: 4.668

10.  Accelerating MR parameter mapping using sparsity-promoting regularization in parametric dimension.

Authors:  Julia V Velikina; Andrew L Alexander; Alexey Samsonov
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.