Literature DB >> 1392247

Practical T2 quantitation for clinical applications.

C S Poon1, R M Henkelman.   

Abstract

Many studies have investigated the use of magnetic resonance relaxation times for tissue characterization. A number have been performed in vivo with clinical whole-body imagers. Unfortunately, the results have yet to establish the role of quantitative tissue relaxation time measurements in clinical diagnosis. One of the major problems is that the techniques used in many of these studies are error prone, making the results inconclusive. In the present study, the problems associated with clinical T2 measurements were systematically evaluated in an attempt to obtain reliable in vivo quantitation. The authors demonstrate that spoiler gradients are the most effective technique for artifact suppression but that they render ineffective radio-frequency phase schemes such as the Meiboom-Gill modification to the Carr-Purcell sequence to compensate experimental imperfections. The present study results in a more reliable multi-echo sequence for T2 measurement. Preliminary clinical results in brain and cervix demonstrate the performance of the new technique.

Mesh:

Year:  1992        PMID: 1392247     DOI: 10.1002/jmri.1880020512

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  98 in total

1.  Advanced MRI of articular cartilage.

Authors:  Hillary J Braun; Garry E Gold
Journal:  Imaging Med       Date:  2011-10

2.  A calorie-restricted diet decreases brain iron accumulation and preserves motor performance in old rhesus monkeys.

Authors:  Erik K Kastman; Auriel A Willette; Christopher L Coe; Barbara B Bendlin; Kris J Kosmatka; Donald G McLaren; Guofan Xu; Elisa Canu; Aaron S Field; Andrew L Alexander; Mary Lou Voytko; T Mark Beasley; Ricki J Colman; Richard H Weindruch; Sterling C Johnson
Journal:  J Neurosci       Date:  2010-06-09       Impact factor: 6.167

3.  Whole brain quantitative T2 MRI across multiple scanners with dual echo FSE: applications to AD, MCI, and normal aging.

Authors:  Corinna M Bauer; Hernán Jara; Ron Killiany
Journal:  Neuroimage       Date:  2010-05-02       Impact factor: 6.556

Review 4.  Magnetic resonance imaging of the knee: optimizing 3 Tesla imaging.

Authors:  Lauren Shapiro; Ernesto Staroswiecki; Garry Gold
Journal:  Semin Roentgenol       Date:  2010-10       Impact factor: 0.800

5.  Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent repetition time (TR) dependence for fast T2 measurement.

Authors:  Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun
Journal:  NMR Biomed       Date:  2011-07-14       Impact factor: 4.044

6.  Quantitative T2 measurement of a single voxel with arbitrary shape using pinwheel excitation and CPMG acquisition.

Authors:  Qin Qin; John C Gore; Robin A de Graaf; Mark D Does
Journal:  MAGMA       Date:  2007-11-13       Impact factor: 2.310

Review 7.  Magnetic resonance imaging of myelin.

Authors:  Cornelia Laule; Irene M Vavasour; Shannon H Kolind; David K B Li; Tony L Traboulsee; G R Wayne Moore; Alex L MacKay
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

8.  Multi-parametric MRI characterization of inflammation in murine skeletal muscle.

Authors:  Nathan D Bryant; Ke Li; Mark D Does; Stephanie Barnes; Daniel F Gochberg; Thomas E Yankeelov; Jane H Park; Bruce M Damon
Journal:  NMR Biomed       Date:  2014-04-29       Impact factor: 4.044

9.  In vivo longitudinal Myelin Water Imaging in rat spinal cord following dorsal column transection injury.

Authors:  Piotr Kozlowski; Paulina Rosicka; Jie Liu; Andrew C Yung; Wolfram Tetzlaff
Journal:  Magn Reson Imaging       Date:  2013-12-27       Impact factor: 2.546

10.  In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

Authors:  Dimitris Mitsouras; Christopher D Owens; Michael S Conte; Hale Ersoy; Mark A Creager; Frank J Rybicki; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.