Literature DB >> 22012743

Applications of stimulated echo correction to multicomponent T2 analysis.

Thomas Prasloski1, Burkhard Mädler, Qing-San Xiang, Alex MacKay, Craig Jones.   

Abstract

We propose a multicomponent fitting algorithm for multiecho T(2) data which allows for correction of T(2) distributions in the presence of stimulated echoes. Tracking the population of spins in many coherence pathways via the iterated method of the Extended Phase Graph algorithm allows for accurate quantification of echo magnitudes. The resulting decay curves allow for correction of errors due to nonideal refocusing pulses as a result of inhomogeneities in the B(1) transmit field. Non-Negative Least Squares fitting is used to quantify the magnitude of T(2) components at various T(2) values. This method, allowing calculation of the T(2) distribution with simultaneous extraction of the refocusing pulse flip angle, requires no change to image acquisition procedures and no extra data input. Validation by means of both simulations and in vivo data shows excellent interscan reproducibility while vastly improving the accuracy of extracted T(2) parameters in voxels where poor B(1) homogeneity leads to refocusing pulse flip angles significantly less than 180°. Most notably, myelin water fraction values in these regions are found to have increased consistency and accuracy.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22012743     DOI: 10.1002/mrm.23157

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  83 in total

1.  Predicting early symptomatic osteoarthritis in the human knee using machine learning classification of magnetic resonance images from the osteoarthritis initiative.

Authors:  Beth G Ashinsky; Mustapha Bouhrara; Christopher E Coletta; Benoit Lehallier; Kenneth L Urish; Ping-Chang Lin; Ilya G Goldberg; Richard G Spencer
Journal:  J Orthop Res       Date:  2017-03-23       Impact factor: 3.494

Review 2.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

Review 3.  Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping.

Authors:  Rachel K Surowiec; Erin P Lucas; Charles P Ho
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-30       Impact factor: 4.342

4.  Fast T2 mapping with multiple echo, Caesar cipher acquisition and model-based reconstruction.

Authors:  Christopher L Lankford; Richard D Dortch; Mark D Does
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

5.  Assessing structure and function of myelin in cervical spondylotic myelopathy: Evidence of demyelination.

Authors:  Hanwen Liu; Erin L MacMillian; Catherine R Jutzeler; Emil Ljungberg; Alex L MacKay; Shannon H Kolind; Burkhard Mädler; David K B Li; Marcel F Dvorak; Armin Curt; Cornelia Laule; John L K Kramer
Journal:  Neurology       Date:  2017-07-12       Impact factor: 9.910

6.  Fast and accurate compensation of signal offset for T2 mapping.

Authors:  Jan Michálek; Pavla Hanzlíková; Tuan Trinh; Dalibor Pacík
Journal:  MAGMA       Date:  2019-02-07       Impact factor: 2.310

7.  Myelin volume fraction imaging with MRI.

Authors:  Kathryn L West; Nathaniel D Kelm; Robert P Carson; Daniel F Gochberg; Kevin C Ess; Mark D Does
Journal:  Neuroimage       Date:  2016-12-23       Impact factor: 6.556

8.  MR measurement of luminal water in prostate gland: Quantitative correlation between MRI and histology.

Authors:  Shirin Sabouri; Ladan Fazli; Silvia D Chang; Richard Savdie; Edward C Jones; S Larry Goldenberg; Peter C Black; Piotr Kozlowski
Journal:  J Magn Reson Imaging       Date:  2017-01-27       Impact factor: 4.813

9.  Myelin water fraction estimation using small-tip fast recovery MRI.

Authors:  Steven T Whitaker; Gopal Nataraj; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  Magn Reson Med       Date:  2020-04-12       Impact factor: 4.668

10.  In vivo longitudinal Myelin Water Imaging in rat spinal cord following dorsal column transection injury.

Authors:  Piotr Kozlowski; Paulina Rosicka; Jie Liu; Andrew C Yung; Wolfram Tetzlaff
Journal:  Magn Reson Imaging       Date:  2013-12-27       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.