Literature DB >> 22392758

Evaluation of patient dose and operator dose in swallowing CT studies performed with a 320-detector-row multislice CT scanner.

Masanao Kobayashi1, Kichiro Koshida, Shoichi Suzuki, Kazuhiro Katada.   

Abstract

Recently, attempts to develop new types of swallowing function analysis with 320-detector-row multislice CT (320-MDCT) have been reported. The present report addresses (1) patient exposure, (2) operator exposure, and (3) spatial dose distribution. For dose measurement, a human-body phantom in which 303 thermoluminescent dosimeter elements were inserted and a survey meter was used. The patient position was confirmed with a single-volume scan at a tube voltage of 120 kV, a tube current of 10 mA, a rotation speed of 0.35 s/rot., a slice thickness of 0.5 mm, coverage of 160 mm, a scan field of view of 240 mm, a small focal spot size, and a gantry tilt angle of 22° (volume CT dose index displayed on the console 0.8 mGy, dose-length product 12.1 mGy cm). The effective dose for the patient in swallowing CT (SCT) was 3.9 mSv. The conversion factor for obtaining the effective dose was 0.0066 mSv/mGy cm. The effective dose for the operator was 0.002 mSv. In the operator exposure measurement, the ambient dose equivalent H*(10), that would be produced by an expanded and aligned radiation field at a depth 10 mm in the International Commission on Radiation Units and Measurements sphere, was 0.012 mSv. In this report, the safety of SCT, which has become possible with the introduction of 320-MDCT, was evaluated by measurement of the exposure to the patient and operator.

Entities:  

Mesh:

Year:  2012        PMID: 22392758     DOI: 10.1007/s12194-012-0148-3

Source DB:  PubMed          Journal:  Radiol Phys Technol        ISSN: 1865-0333


  14 in total

1.  Radiation dose for routine clinical adult brain CT: Variability on different scanners at one institution.

Authors:  Tracy A Jaffe; Jenny K Hoang; Terry T Yoshizumi; Greta Toncheva; Carolyn Lowry; Carl Ravin
Journal:  AJR Am J Roentgenol       Date:  2010-08       Impact factor: 3.959

2.  Comparison of image quality and lens dose in helical and sequentially acquired head CT.

Authors:  N Abdeen; S Chakraborty; T Nguyen; M P dos Santos; M Donaldson; G Heddon; B A Schwarz
Journal:  Clin Radiol       Date:  2010-08-06       Impact factor: 2.350

3.  Radiation dose in videofluoroscopic swallow studies.

Authors:  Ivan Zammit-Maempel; Claire-Louise Chapple; Paula Leslie
Journal:  Dysphagia       Date:  2006-10-06       Impact factor: 3.438

4.  Evaluation of swallowing using 320-detector-row multislice CT. Part I: single- and multiphase volume scanning for three-dimensional morphological and kinematic analysis.

Authors:  Naoko Fujii; Yoko Inamoto; Eiichi Saitoh; Mikoto Baba; Sumiko Okada; Satoshi Yoshioka; Toshiaki Nakai; Yoshihiro Ida; Kazuhiro Katada; Jeffrey B Palmer
Journal:  Dysphagia       Date:  2010-01-20       Impact factor: 3.438

5.  Survey of computed tomography doses and establishment of national diagnostic reference levels in the Republic of Belarus.

Authors:  S A Kharuzhyk; S A Matskevich; A E Filjustin; E V Bogushevich; S A Ugolkova
Journal:  Radiat Prot Dosimetry       Date:  2010-02-24       Impact factor: 0.972

6.  Evaluation of swallowing using 320-detector-row multislice CT. Part II: kinematic analysis of laryngeal closure during normal swallowing.

Authors:  Yoko Inamoto; Naoko Fujii; Eiichi Saitoh; Mikoto Baba; Sumiko Okada; Kazuhiro Katada; Yasunori Ozeki; Daisuke Kanamori; Jeffrey B Palmer
Journal:  Dysphagia       Date:  2010-03-05       Impact factor: 3.438

7.  Measurement of radiation dose in cerebral CT perfusion study.

Authors:  Masaaki Hirata; Yoshifumi Sugawara; Yukimi Fukutomi; Kenji Oomoto; Kenya Murase; Hitoshi Miki; Teruhito Mochizuki
Journal:  Radiat Med       Date:  2005-03

8.  Evaluation of radiation doses from MDCT-imaging in otolaryngology.

Authors:  Chiyo Yamauchi-Kawaura; Keisuke Fujii; Takahiko Aoyama; Masato Yamauchi; Shuji Koyama
Journal:  Radiat Prot Dosimetry       Date:  2009-07-18       Impact factor: 0.972

9.  Patient dose during videofluoroscopy swallowing studies in a Hong Kong public hospital.

Authors:  Koon Ho Torrance Chau; Chak Man Andy Kung
Journal:  Dysphagia       Date:  2009-04-24       Impact factor: 3.438

10.  Managing patient dose in multi-detector computed tomography(MDCT). ICRP Publication 102.

Authors:  J Valentin
Journal:  Ann ICRP       Date:  2007
View more
  2 in total

1.  Influence of difference in cross-sectional dose profile in a CTDI phantom on X-ray CT dose estimation: a Monte Carlo study.

Authors:  Tomonobu Haba; Shuji Koyama; Yoshihiro Ida
Journal:  Radiol Phys Technol       Date:  2013-11-24

2.  Radiation doses for pregnant women in the late pregnancy undergoing fetal-computed tomography: a comparison of dosimetry and Monte Carlo simulations.

Authors:  Yuta Matsunaga; Ai Kawaguchi; Masanao Kobayashi; Shigetaka Suzuki; Shoichi Suzuki; Koichi Chida
Journal:  Radiol Phys Technol       Date:  2016-09-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.