Prospective self-gated nonenhanced magnetic resonance angiography of the peripheral arteries.

Erik J Offerman1, Ioannis Koktzoglou, Christopher Glielmi, Anindya Sen, Robert R Edelman.   

Abstract

Most nonenhanced MRA techniques for evaluating peripheral artery disease (PAD) require cardiac synchronization through physiological gating. Electrocardiographic gating is the most popular method for cardiac synchronization; however, it is subject to interference from switching magnetic field gradients and radiofrequency pulses. A method is described for self-gated nonenhanced MRA that does not require the use of electrocardiographic gating. Imaging was prospectively triggered by detecting the acceleration of blood flow during systole with a reference-less phase contrast navigator. The technique was implemented for nonsubtractive nonenhanced MRA using quiescent-interval single-shot MRA. The lower extremity peripheral arteries of eight healthy subjects were imaged using electrocardiographic-, pulse-, and self-gated quiescent-interval single-shot. Self-gated quiescent-interval single-shot triggered with 99% accuracy. There were no significant differences in relative contrast, contrast-to-noise ratio, or image quality between self-gated and electrocardiographic-gated quiescent-interval single-shot MRA (P > 0.05). Image quality with pulse gating was inferior.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22392645      PMCID: PMC3376657          DOI: 10.1002/mrm.24240

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  15 in total

1.  Non-contrast-enhanced MR angiography using 3D ECG-synchronized half-Fourier fast spin echo.

Authors:  M Miyazaki; S Sugiura; F Tateishi; H Wada; Y Kassai; H Abe
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

2.  Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences.

Authors:  J Felblinger; J Slotboom; R Kreis; B Jung; C Boesch
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

3.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Concomitant gradient terms in phase contrast MR: analysis and correction.

Authors:  M A Bernstein; X J Zhou; J A Polzin; K F King; A Ganin; N J Pelc; G H Glover
Journal:  Magn Reson Med       Date:  1998-02       Impact factor: 4.668

5.  Quantitative flow measurement in phase contrast MR angiography.

Authors:  M F Walker; S P Souza; C L Dumoulin
Journal:  J Comput Assist Tomogr       Date:  1988 Mar-Apr       Impact factor: 1.826

6.  MR angiography with two-dimensional acquisition and three-dimensional display. Work in progress.

Authors:  P J Keller; B P Drayer; E K Fram; K D Williams; C L Dumoulin; S P Souza
Journal:  Radiology       Date:  1989-11       Impact factor: 11.105

7.  Electrocardiogram acquisition during MR examinations for patient monitoring and sequence triggering.

Authors:  J Felblinger; C Lehmann; C Boesch
Journal:  Magn Reson Med       Date:  1994-10       Impact factor: 4.668

8.  The effect of rapid rise-time magnetic fields on the ECG of the rat.

Authors:  M J Polson; A T Barker; S Gardiner
Journal:  Clin Phys Physiol Meas       Date:  1982-08

9.  Peripheral arterial disease detection, awareness, and treatment in primary care.

Authors:  A T Hirsch; M H Criqui; D Treat-Jacobson; J G Regensteiner; M A Creager; J W Olin; S H Krook; D B Hunninghake; A J Comerota; M E Walsh; M M McDermott; W R Hiatt
Journal:  JAMA       Date:  2001-09-19       Impact factor: 56.272

10.  Automated rectilinear self-gated cardiac cine imaging.

Authors:  Mark E Crowe; Andrew C Larson; Qiang Zhang; James Carr; Richard D White; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

View more
  5 in total

1.  Prospective cardiac motion self-gating.

Authors:  Fei Han; Stanislas Rapacchi; Peng Hu
Journal:  Quant Imaging Med Surg       Date:  2017-04

2.  A meta-analysis of the diagnostic performance of quiescent-interval-single-shot magnetic resonance angiography in peripheral arterial disease.

Authors:  Mansi Verma; Niraj Nirmal Pandey; Vishwajeet Singh; Priya Jagia
Journal:  Eur Radiol       Date:  2021-11-12       Impact factor: 7.034

3.  MRI in Lower Extremity Peripheral Arterial Disease: Recent Advancements.

Authors:  Amy W Pollak; Christopher M Kramer
Journal:  Curr Cardiovasc Imaging Rep       Date:  2013-02-01

4.  Quantification of myocardial perfusion with self-gated cardiovascular magnetic resonance.

Authors:  Devavrat Likhite; Ganesh Adluru; Nan Hu; Chris McGann; Edward DiBella
Journal:  J Cardiovasc Magn Reson       Date:  2015-02-12       Impact factor: 5.364

5.  Non-contrast-enhanced MR angiography at 3 Tesla in patients with advanced peripheral arterial occlusive disease.

Authors:  Kolja M Thierfelder; Georgios Meimarakis; Konstantin Nikolaou; Wieland H Sommer; Peter Schmitt; Philipp M Kazmierczak; Maximilian F Reiser; Daniel Theisen
Journal:  PLoS One       Date:  2014-03-07       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.