Literature DB >> 10332846

Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences.

J Felblinger1, J Slotboom, R Kreis, B Jung, C Boesch.   

Abstract

A generally applicable method for almost complete suppression of signal artifacts on electrophysiological signals caused by B0-gradient switching (gradient noise) is presented. The method is demonstrated for electrocardiograms (ECGs) but can also be used for other electrophysiological signals. It takes advantage of the fact that under certain conditions, the effect of switching the B0-field gradient upon an electrophysiological signal can be modeled as a linear time-invariant system and fully characterized by pulse response functions. It is shown how the system's pulse response functions of the X, Y, and Z gradients can be determined and how gradient noise can be eliminated efficiently. The elimination of gradient noise by the proposed method causes in the current arrangement a constant delay of 128 msec, which is acceptable for patient monitoring and magnetic resonance sequence triggering.

Entities:  

Mesh:

Year:  1999        PMID: 10332846     DOI: 10.1002/(sici)1522-2594(199904)41:4<715::aid-mrm9>3.0.co;2-7

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Adaptive removal of gradients-induced artefacts on ECG in MRI: a performance analysis of RLS filtering.

Authors:  Mario Sansone; Luciano Mirarchi; Marcello Bracale
Journal:  Med Biol Eng Comput       Date:  2010-03-18       Impact factor: 2.602

2.  Visual evoked potentials recovered from fMRI scan periods.

Authors:  Robert Becker; Petra Ritter; Matthias Moosmann; Arno Villringer
Journal:  Hum Brain Mapp       Date:  2005-11       Impact factor: 5.038

3.  Adaptive step size LMS improves ECG detection during MRI at 1.5 and 3 T.

Authors:  André Guillou; Jean-Marc Sellal; Sarah Ménétré; Grégory Petitmangin; Jacques Felblinger; Laurent Bonnemains
Journal:  MAGMA       Date:  2017-06-19       Impact factor: 2.310

4.  Prospective self-gated nonenhanced magnetic resonance angiography of the peripheral arteries.

Authors:  Erik J Offerman; Ioannis Koktzoglou; Christopher Glielmi; Anindya Sen; Robert R Edelman
Journal:  Magn Reson Med       Date:  2012-03-05       Impact factor: 4.668

5.  Adaptive noise cancellation to suppress electrocardiography artifacts during real-time interventional MRI.

Authors:  Vincent Wu; Israel M Barbash; Kanishka Ratnayaka; Christina E Saikus; Merdim Sonmez; Ozgur Kocaturk; Robert J Lederman; Anthony Z Faranesh
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

6.  Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates.

Authors:  R Abächerli; C Pasquier; F Odille; M Kraemer; J-J Schmid; J Felblinger
Journal:  MAGMA       Date:  2005-02-07       Impact factor: 2.310

7.  Presurgical brain mapping in epilepsy using simultaneous EEG and functional MRI at ultra-high field: feasibility and first results.

Authors:  Frédéric Grouiller; João Jorge; Francesca Pittau; Wietske van der Zwaag; Giannina Rita Iannotti; Christoph Martin Michel; Serge Vulliémoz; Maria Isabel Vargas; François Lazeyras
Journal:  MAGMA       Date:  2016-03-05       Impact factor: 2.310

8.  Synchronisation strategies in T2-weighted MR imaging for detection of liver lesions: Application on a nude mouse model.

Authors:  L Baboi; L Milot; C Lartizien; C Roche; J-Y Scoazec; F Pilleul; O Beuf
Journal:  Biomed Imaging Interv J       Date:  2007-10-01

9.  Reference signal extraction from corrupted ECG using wavelet decomposition for MRI sequence triggering: application to small animals.

Authors:  Dima Abi-Abdallah; Eric Chauvet; Latifa Bouchet-Fakri; Alain Bataillard; André Briguet; Odette Fokapu
Journal:  Biomed Eng Online       Date:  2006-02-20       Impact factor: 2.819

10.  ECG-based gating in ultra high field cardiovascular magnetic resonance using an independent component analysis approach.

Authors:  Johannes W Krug; Georg Rose; Gari D Clifford; Julien Oster
Journal:  J Cardiovasc Magn Reson       Date:  2013-11-19       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.