Literature DB >> 9469714

Concomitant gradient terms in phase contrast MR: analysis and correction.

M A Bernstein1, X J Zhou, J A Polzin, K F King, A Ganin, N J Pelc, G H Glover.   

Abstract

Whenever a linear gradient is activated, concomitant magnetic fields with non-linear spatial dependence result. This is a consequence of Maxwell's equations, i.e., within the imaging volume the magnetic field must have zero divergence, and has negligible curl. The concomitant, or Maxwell field has been described in the MRI literature for over 10 years. In this paper, we theoretically and experimentally show the existence of two additional lowest-order terms in the concomitant field, which we call cross-terms. The concomitant gradient cross-terms only arise when the longitudinal gradient Gz is simultaneously active with a transverse gradient (Gx or Gy). The effect of all of the concomitant gradient terms on phase contrast imaging is examined in detail. Several methods for reducing or eliminating phase errors arising from the concomitant magnetic field are described. The feasibility of a joint pulse sequence-reconstruction method, which requires no increase in minimum TE, is demonstrated. Since the lowest-order terms of the concomitant field are proportional to G2/B0, the importance of concomitant gradient terms is expected to increase given the current interest in systems with stronger gradients and/or weaker main magnetic fields.

Mesh:

Year:  1998        PMID: 9469714     DOI: 10.1002/mrm.1910390218

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  163 in total

1.  Three dimensional flow in the human left atrium.

Authors:  A Fyrenius; L Wigström; T Ebbers; M Karlsson; J Engvall; A F Bolger
Journal:  Heart       Date:  2001-10       Impact factor: 5.994

2.  Assessment of early diastolic strain-velocity temporal relationships using spatial modulation of magnetization with polarity alternating velocity encoding (SPAMM-PAV).

Authors:  Ziheng Zhang; Donald P Dione; Peter B Brown; Erik M Shapiro; Albert J Sinusas; Smita Sampath
Journal:  Magn Reson Med       Date:  2011-05-31       Impact factor: 4.668

3.  Synthetic dataset generation for the analysis and the evaluation of image-based hemodynamics of the human aorta.

Authors:  Umberto Morbiducci; Raffaele Ponzini; Giovanna Rizzo; Marco Evanghelos Biancolini; Francesco Iannaccone; Diego Gallo; Alberto Redaelli
Journal:  Med Biol Eng Comput       Date:  2011-12-23       Impact factor: 2.602

4.  DENSE: displacement encoding with stimulated echoes in cardiac functional MRI.

Authors:  A H Aletras; S Ding; R S Balaban; H Wen
Journal:  J Magn Reson       Date:  1999-03       Impact factor: 2.229

5.  Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.

Authors:  Ningbo Yu; Roger Gassert; Robert Riener
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-09-02       Impact factor: 2.924

Review 6.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

7.  Caval to pulmonary 3D flow distribution in patients with Fontan circulation and impact of potential 4D flow MRI error sources.

Authors:  Kelly Jarvis; Susanne Schnell; Alex J Barker; Michael Rose; Joshua D Robinson; Cynthia K Rigsby; Michael Markl
Journal:  Magn Reson Med       Date:  2018-09-15       Impact factor: 4.668

8.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

9.  Improved quantification and mapping of anomalous pulmonary venous flow with four-dimensional phase-contrast MRI and interactive streamline rendering.

Authors:  Albert Hsiao; Ufra Yousaf; Marcus T Alley; Michael Lustig; Frandics Pak Chan; Beverley Newman; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

10.  Improved accuracy in flow mapping of congenital heart disease using stationary phantom technique.

Authors:  Thomas A Miller; Andrew B Landes; Adrian M Moran
Journal:  J Cardiovasc Magn Reson       Date:  2009-12-10       Impact factor: 5.364

View more