PURPOSE: To compare intraocular pressure (IOP) over time after standard trabeculectomy vs Ex-PRESS implantation in patients with bilateral primary open-angle glaucoma (POAG).
DESIGN: Prospective, randomised study. PATIENTS AND METHODS: This study included adult patients with bilateral POAG necessitating surgery. Each patient underwent trabeculectomy in one eye and Ex-PRESS implantation under a scleral flap in the other eye according to randomised contralateral allocations. Efficacy was assessed by IOP values and success rates (IOP threshold and/or need for topical glaucoma medication) during 30 months. Statistical analysis included Generalised Estimate Equation and Cox Survival models, and paired t-tests.
RESULTS: Thirty eyes of 15 patients were studied for a mean of 23.6 months (SD, ± 6.9). At the last follow-up visit, mean pre-operative IOP decreased from 31.1 (± 14.2) to 16.2 (± 1.5) mm Hg after trabeculectomy, and from 28.1 (± 9.0) to 15.7 (± 1.8) mm Hg after Ex-PRESS implantation (P=0.001). The mean number of anti-glaucoma medicines prescribed at the last follow-up decreased from 3.7 pre-operatively (both groups) to 0.9 after trabeculectomy vs 0.3 after Ex-PRESS implantation (P=0.001). Complete success rates (5<IOP<18 mm Hg without medications) were higher with Ex-PRESS compared with trabeculectomy (P=0.0024). Postoperative complications were more frequent after trabeculectomy (33%) compared with Ex-PRESS (20%), with four trabeculectomy eyes (27%) needing postoperative interventions, compared with none with Ex-PRESS.
CONCLUSIONS: Trabeculectomy and Ex-PRESS implantation provided similar IOP control, but the Ex-PRESS group had a lower rate of complications, fewer postoperative interventions, and needed less glaucoma medications.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22344189      PMCID: PMC3351049          DOI: 10.1038/eye.2012.13

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  33 in total

1.  Comparison of trabeculectomy with Ex-PRESS miniature glaucoma device implanted under scleral flap.

Authors:  Peter J G Maris; Kyoko Ishida; Peter A Netland
Journal:  J Glaucoma       Date:  2007-01       Impact factor: 2.503

2.  Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery.

Authors:  Elliott M Kanner; Peter A Netland; Steven R Sarkisian; Haiming Du
Journal:  J Glaucoma       Date:  2009-08       Impact factor: 2.503

3.  [Postoperative outcomes after combined glaucoma surgery. Comparison of ex-press miniature implant with standard trabeculectomy].

Authors:  R Gallego-Pinazo; E López-Sánchez; J Marín-Montiel
Journal:  Arch Soc Esp Oftalmol       Date:  2009-06

4.  Assessment of bleb morphologic features and postoperative outcomes after Ex-PRESS drainage device implantation versus trabeculectomy.

Authors:  Travis J Good; Malik Y Kahook
Journal:  Am J Ophthalmol       Date:  2011-01-13       Impact factor: 5.258

Review 5.  Nonpenetrating glaucoma surgery: a critical evaluation.

Authors:  Usman Sarodia; Tarek Shaarawy; Keith Barton
Journal:  Curr Opin Ophthalmol       Date:  2007-03       Impact factor: 3.761

6.  Efficacy and safety of a steel drainage device implanted under a scleral flap.

Authors:  Fabio De Feo; Alessandro Bagnis; Graziano Bricola; Riccardo Scotto; Carlo Enrico Traverso
Journal:  Can J Ophthalmol       Date:  2009-08       Impact factor: 1.882

7.  Histological biocompatibility of a stainless steel miniature glaucoma drainage device in humans: a case report.

Authors:  Fabio De Feo; Stewart Jacobson; Abraham Nyska; Paola Pagani; Carlo Enrico Traverso
Journal:  Toxicol Pathol       Date:  2009-06       Impact factor: 1.902

8.  Exposure of Ex-PRESS Miniature Glaucoma Devices: case series and technique for tube shunt removal.

Authors:  Joshua D Stein; Leon W Herndon; J Brent Bond; Pratap Challa
Journal:  J Glaucoma       Date:  2007-12       Impact factor: 2.503

9.  The Ex-PRESS glaucoma shunt versus trabeculectomy in open-angle glaucoma: a prospective randomized study.

Authors:  Leo A M S de Jong
Journal:  Adv Ther       Date:  2009-04-03       Impact factor: 3.845

Review 10.  Ex-PRESS mini glaucoma shunt: surgical technique and review of clinical experience.

Authors:  Andrew M Hendrick; Malik Y Kahook
Journal:  Expert Rev Med Devices       Date:  2008-11       Impact factor: 3.166

View more
  37 in total

1.  Imaging of filtering blebs after implantation of the Ex-PRESS shunt with the use of the Visante optical coherence tomography.

Authors:  Aristeidis Konstantinidis; Georgios D Panos; Magdalini Triantafylla; Georgios Labiris; Efthimia Tsaragli; Zisis Gatzioufas; Vassilios Kozobolis
Journal:  Int J Ophthalmol       Date:  2015-06-18       Impact factor: 1.779

2.  Ex-PRESS implantation versus trabeculectomy in Chinese patients with POAG: fellow eye pilot study.

Authors:  Wei Wang; Min-Wen Zhou; Wen-Bin Huang; Xin-Bo Gao; Xiu-Lan Zhang
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

3.  Long-term efficacy and safety of ExPress implantation for treatment of open angle glaucoma.

Authors:  Geun Young Lee; Chong Eun Lee; Kyoo Won Lee; Sam Seo
Journal:  Int J Ophthalmol       Date:  2017-09-18       Impact factor: 1.779

4.  Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma.

Authors:  Kyoko Ishida; Naoya Moroto; Kazuhiro Murata; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2017-04-03       Impact factor: 2.447

5.  Modified deep sclerectomy combined with Ex-PRESS filtration device versus trabeculectomy for primary open angle glaucoma.

Authors:  Vassilios Kozobolis; Georgios D Panos; Aristeidis Konstantinidis; Miguel Teus; Georgios Labiris
Journal:  Int J Ophthalmol       Date:  2017-05-18       Impact factor: 1.779

6.  Trabeculectomy with Ex-PRESS implant versus Ahmed glaucoma valve implantation-a comparative study.

Authors:  Michael Waisbourd; Naomi Fischer; Hadas Shalev; Oriel Spierer; Elad Ben Artsi; Rony Rachmiel; Gabi Shemesh; Shimon Kurtz
Journal:  Int J Ophthalmol       Date:  2016-10-18       Impact factor: 1.779

Review 7.  Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device.

Authors:  C Mariotti; E Dahan; M Nicolai; L Levitz; S Bouee
Journal:  Eye (Lond)       Date:  2013-11-15       Impact factor: 3.775

8.  Efficacy and economic analysis of Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a systematic review and Meta-analysis.

Authors:  Ling Wang; Fang Sha; Da-Dong Guo; Hong-Sheng Bi; Jun-Kang Si; Yu-Xiang Du; Kai Tang
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

9.  Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a meta-analysis.

Authors:  Wei Wang; Minwen Zhou; Wenbin Huang; Xiulan Zhang
Journal:  PLoS One       Date:  2013-05-31       Impact factor: 3.240

Review 10.  Device-modified trabeculectomy for glaucoma.

Authors:  Xue Wang; Rabeea Khan; Anne Coleman
Journal:  Cochrane Database Syst Rev       Date:  2015-12-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.