Ex-PRESS miniature glaucoma device implanted under a scleral flap alone or combined with phacoemulsification cataract surgery.

Elliott M Kanner1, Peter A Netland, Steven R Sarkisian, Haiming Du.   

Abstract

PURPOSE: Our purpose was to evaluate the clinical outcomes of the Ex-PRESS miniature glaucoma device placed under a partial-thickness scleral flap as a single procedure or combined with phacoemulsification cataract surgery.
METHODS: This was a comparative consecutive case series of 345 eyes: 231 eyes treated with Ex-PRESS implant under scleral flap alone and 114 eyes treated with Ex-PRESS implant under scleral flap combined with phacoemulsification (both groups were treated intraoperatively with mitomycin C).
RESULTS: The patients were followed for 25.7+/-11.1 (range, 1 to 46.2) months (Ex-PRESS alone) and 21.9+/-12.5 (range, 1.9 to 46.2) months (combined cases). At 3 years after surgery, surgical success was 94.8% and 95.6% in the Ex-PRESS and combined groups, respectively (P=0.948). Compared with baseline values, the postoperative intraocular pressure (IOP) and number of glaucoma medications were significantly lowered in both groups. The change from baseline IOP was significantly greater after Ex-PRESS implant alone compared with combined surgery (P<0.001). The most common device-related complication was obstruction of the tube (6 eyes), which was treated successfully with Nd:YAG laser in all 6 eyes.
CONCLUSIONS: The use of the Ex-PRESS implant under a scleral flap was effective for lowering IOP both alone and combined with cataract surgery. The most common device-related complication was tube blockage, which was treated with the Nd:YAG laser.

Entities:  

Mesh:

Year:  2009        PMID: 19223790     DOI: 10.1097/IJG.0b013e31818fb44e

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  23 in total

1.  Evaluation of the Ex-PRESS(®) P-50 implant under scleral flap in combined cataract and glaucoma surgery.

Authors:  Valentín Huerva; Jordi Soldevila; Francisco J Ascaso; Laura Lavilla; M Jesús Muniesa; M Carmen Sánchez
Journal:  Int J Ophthalmol       Date:  2016-04-18       Impact factor: 1.779

2.  Ex-PRESS implantation with phacoemulsification in POAG versus CPACG.

Authors:  Jie Lan; Da-Peng Sun; Jie Wu; Ya-Ni Wang; Li-Xin Xie
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

3.  Comparison of trabeculectomy and Ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised study.

Authors:  E Dahan; G J Ben Simon; A Lafuma
Journal:  Eye (Lond)       Date:  2012-02-17       Impact factor: 3.775

4.  Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma.

Authors:  Kyoko Ishida; Naoya Moroto; Kazuhiro Murata; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2017-04-03       Impact factor: 2.447

5.  Risk factors for Ex-Press® surgery failure.

Authors:  Mitsuya Otsuka; Naoki Tojo; Atsushi Hayashi
Journal:  Int Ophthalmol       Date:  2022-10-13       Impact factor: 2.029

6.  Efficacy and Safety of the Preserflo Microshunt With Mitomycin C for the Treatment of Open Angle Glaucoma.

Authors:  Marta Ibarz Barberá; Fátima Martínez-Galdón; Elena Caballero-Magro; Marta Rodríguez-Piñero; Pedro Tañá-Rivero
Journal:  J Glaucoma       Date:  2022-05-17       Impact factor: 2.290

7.  Risk of endophthalmitis and other long-term complications of trabeculectomy in the Collaborative Initial Glaucoma Treatment Study (CIGTS).

Authors:  Sarwar Zahid; David C Musch; Leslie M Niziol; Paul R Lichter
Journal:  Am J Ophthalmol       Date:  2012-12-13       Impact factor: 5.258

8.  The ex-press mini glaucoma shunt: technique and experience.

Authors:  Steven R Sarkisian
Journal:  Middle East Afr J Ophthalmol       Date:  2009-07

Review 9.  Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device.

Authors:  C Mariotti; E Dahan; M Nicolai; L Levitz; S Bouee
Journal:  Eye (Lond)       Date:  2013-11-15       Impact factor: 3.775

Review 10.  Standard Trabeculectomy and Ex-PRESS Miniature Glaucoma Shunt: A Comparative Study and Literature Review.

Authors:  Elad Moisseiev; Eran Zunz; Rotem Tzur; Shimon Kurtz; Gabi Shemesh
Journal:  J Glaucoma       Date:  2015-08       Impact factor: 2.503

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.