Assessment of bleb morphologic features and postoperative outcomes after Ex-PRESS drainage device implantation versus trabeculectomy.

Travis J Good1, Malik Y Kahook.   

Abstract

PURPOSE: To investigate bleb morphologic features and postoperative outcomes after Ex-PRESS drainage device (Alcon Laboratories) implantation versus trabeculectomy.
DESIGN: Retrospective, consecutive case-control series.
METHODS: Information was collected from the charts of 35 consecutive Ex-PRESS procedures and 35 consecutive trabeculectomy procedures with at least 2 years of follow-up. Intraocular pressure (IOP), bleb morphologic features, reduction of dependence on medication, visual recovery, number of postoperative visits, and postoperative complication rates were compared between groups.
RESULTS: Average follow-up was 28 months (standard deviation, 3.23 months). Mean IOP measurements were similar after 6 months, then became slightly higher in the Ex-PRESS group at 1 year and at the final follow-up (P = .004 and P = .008, respectively). Final percent IOP lowering was similar between groups (P = .209). Unqualified success was achieved in 77.14% of Ex-PRESS and 74.29% of trabeculectomy procedures at last follow-up (P = 1.00). An additional 5.71% and 8.57% reached qualified success for Ex-PRESS and trabeculectomy surgeries, respectively (P = .99). Evaluation by the Moorfields Bleb Grading System revealed less vascularity and height but more diffuse area associated with the Ex-PRESS blebs, although these differences were absent at study completion. There were fewer cases of early postoperative hypotony and hyphema and quicker visual recovery in the Ex-PRESS group. The Ex-PRESS group required fewer postoperative visits compared with the trabeculectomy group (P < .000).
CONCLUSIONS: Success of Ex-PRESS surgery, as defined in our study, was similar to trabeculectomy. Final IOP measurements were slightly lower after trabeculectomy compared with Ex-PRESS. Differences in some postoperative outcomes faded with follow-up. There remains a need for long-term prospective studies comparing these 2 procedures.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21236403     DOI: 10.1016/j.ajo.2010.09.004

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  41 in total

1.  Visual acuity and corneal higher-order aberrations after EX-PRESS or trabeculectomy, and the determination of associated factors that influence visual function.

Authors:  Nobuko Kobayashi; Kazuyuki Hirooka; Eri Nitta; Kaori Ukegawa; Akitaka Tsujikawa
Journal:  Int Ophthalmol       Date:  2017-08-10       Impact factor: 2.031

2.  Ex-PRESS implantation versus trabeculectomy in Chinese patients with POAG: fellow eye pilot study.

Authors:  Wei Wang; Min-Wen Zhou; Wen-Bin Huang; Xin-Bo Gao; Xiu-Lan Zhang
Journal:  Int J Ophthalmol       Date:  2017-01-18       Impact factor: 1.779

3.  Clinical outcomes after Ex-PRESS glaucoma shunt versus non-penetrating deep sclerectomy: two-year follow-up.

Authors:  Beatriz Puerto; Cristina López-Caballero; Carmen Sánchez-Sánchez; Noelia Oblanca; Vanesa Blázquez; Inés Contreras
Journal:  Int Ophthalmol       Date:  2017-11-24       Impact factor: 2.031

4.  Comparison of trabeculectomy and Ex-PRESS implantation in fellow eyes of the same patient: a prospective, randomised study.

Authors:  E Dahan; G J Ben Simon; A Lafuma
Journal:  Eye (Lond)       Date:  2012-02-17       Impact factor: 3.775

5.  Effect of glaucoma implant surgery on intraocular pressure reduction, flare count, anterior chamber depth, and corneal endothelium in primary open-angle glaucoma.

Authors:  Kyoko Ishida; Naoya Moroto; Kazuhiro Murata; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2017-04-03       Impact factor: 2.447

6.  Trabeculectomy with Ex-PRESS implant versus Ahmed glaucoma valve implantation-a comparative study.

Authors:  Michael Waisbourd; Naomi Fischer; Hadas Shalev; Oriel Spierer; Elad Ben Artsi; Rony Rachmiel; Gabi Shemesh; Shimon Kurtz
Journal:  Int J Ophthalmol       Date:  2016-10-18       Impact factor: 1.779

Review 7.  Long-term outcomes and risk factors for failure with the EX-press glaucoma drainage device.

Authors:  C Mariotti; E Dahan; M Nicolai; L Levitz; S Bouee
Journal:  Eye (Lond)       Date:  2013-11-15       Impact factor: 3.775

8.  Efficacy and economic analysis of Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a systematic review and Meta-analysis.

Authors:  Ling Wang; Fang Sha; Da-Dong Guo; Hong-Sheng Bi; Jun-Kang Si; Yu-Xiang Du; Kai Tang
Journal:  Int J Ophthalmol       Date:  2016-01-18       Impact factor: 1.779

Review 9.  Recent Advances in the Surgical Management of Glaucoma in Exfoliation Syndrome.

Authors:  Mohamed S Sayed; Richard K Lee
Journal:  J Glaucoma       Date:  2018-07       Impact factor: 2.503

Review 10.  Device-modified trabeculectomy for glaucoma.

Authors:  Xue Wang; Rabeea Khan; Anne Coleman
Journal:  Cochrane Database Syst Rev       Date:  2015-12-01