Literature DB >> 22301169

Laser processed TiN reinforced Ti6Al4V composite coatings.

Vamsi Krishna Balla1, Abhimanyu Bhat, Susmita Bose, Amit Bandyopadhyay.   

Abstract

The purpose of this first generation investigation is to evaluate fabrication, in vitro cytotoxicity, cell-material interactions and tribological performance of TiN particle reinforced Ti6Al4V composite coatings for potential wear resistant load bearing implant applications. The microstructural analysis of the composites was performed using scanning electron microscope and phase analysis was done with X-ray diffraction. In vitro cell-material interactions, using human fetal osteoblast cell line, have been assessed on these composite coatings and compared with Ti6Al4V alloy control samples. The tribological performance of the coatings were evaluated, in simulated body fluids, up to 1000 m sliding distance under 10 N normal load. The results show that the composite coatings contain distinct TiN particles embedded in α+β phase matrix. The average top surface hardness of Ti6Al4V alloy increased from 394±8 HV to 1138±61 HV with 40 wt% TiN reinforcement. Among the composite coatings, the coatings reinforced with 40 wt% TiN exhibited the highest wear resistance of 3.74×10(-6) mm(3)/Nm, which is lower than the wear rate, 1.04×10(-5) mm(3)/Nm, of laser processed CoCrMo alloy tested under identical experimental conditions. In vitro biocompatibility study showed that these composite coatings were non-toxic and provides superior cell-material interactions compared to Ti6Al4V control, as a result of their high surface energy. In summary, excellent in vitro wear resistance and biocompatibility of present laser processed TiN reinforced Ti6Al4V alloy composite coatings clearly show their potential as wear resistant contact surfaces for load bearing implant applications.
Copyright © 2011 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22301169      PMCID: PMC3272254          DOI: 10.1016/j.jmbbm.2011.09.007

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  20 in total

1.  Osteoclast adhesion and activity on synthetic hydroxyapatite, carbonated hydroxyapatite, and natural calcium carbonate: relationship to surface energies.

Authors:  S A Redey; S Razzouk; C Rey; D Bernache-Assollant; G Leroy; M Nardin; G Cournot
Journal:  J Biomed Mater Res       Date:  1999-05

2.  In vitro Wear Rate and Co Ion Release of Compositionally and Structurally Graded CoCrMo-Ti6Al4V Structures.

Authors:  Stanley Dittrick; Vamsi Krishna Balla; Susmita Bose; Amit Bandyopadhyay
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2011-05-10       Impact factor: 7.328

3.  PIRAC Ti nitride coated Ti-6AI-4V head against UHMWPE acetabular cup-hip wear simulator study.

Authors:  E Y Gutmanas; I Gotman
Journal:  J Mater Sci Mater Med       Date:  2004-04       Impact factor: 3.896

Review 4.  Clinical reviews: particulate debris and failure of total hip replacements.

Authors:  M Jasty
Journal:  J Appl Biomater       Date:  1993

5.  Fabrication of porous NiTi shape memory alloy structures using laser engineered net shaping.

Authors:  B Vamsi Krishna; Susmita Bose; Amit Bandyopadhyay
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-05       Impact factor: 3.368

6.  The in-vivo wear performance of prosthetic femoral heads with titanium nitride coating.

Authors:  M T Raimondi; R Pietrabissa
Journal:  Biomaterials       Date:  2000-05       Impact factor: 12.479

7.  Wear-accelerated corrosion of Ti-6Al-4V and nitrogen-ion-implanted Ti-6Al-4V: mechanisms and influence of fixed-stress magnitude.

Authors:  R A Buchanan; E D Rigney; J M Williams
Journal:  J Biomed Mater Res       Date:  1987-03

8.  Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon.

Authors:  V Saikko; T Ahlroos; O Calonius; J Keränen
Journal:  Biomaterials       Date:  2001-06       Impact factor: 12.479

9.  Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion.

Authors:  N J Hallab; K J Bundy; K O'Connor; R L Moses; J J Jacobs
Journal:  Tissue Eng       Date:  2001-02

10.  The effect of surface chemistry and structure of titanium nitride (TiN) films on primary hippocampal cells.

Authors:  L A Cyster; D M Grant; K G Parker; T L Parker
Journal:  Biomol Eng       Date:  2002-08
View more
  4 in total

Review 1.  Effects of surface coating on reducing friction and wear of orthopaedic implants.

Authors:  Hee Ay Ching; Dipankar Choudhury; Md Julker Nine; Noor Azuan Abu Osman
Journal:  Sci Technol Adv Mater       Date:  2014-01-07       Impact factor: 8.090

2.  Laser-modified titanium surfaces enhance the osteogenic differentiation of human mesenchymal stem cells.

Authors:  Tatiana A B Bressel; Jana Dara Freires de Queiroz; Susana Margarida Gomes Moreira; Jéssyca T da Fonseca; Edson A Filho; Antônio Carlos Guastaldi; Silvia Regina Batistuzzo de Medeiros
Journal:  Stem Cell Res Ther       Date:  2017-11-28       Impact factor: 6.832

3.  Modification of the Ceramic Implant Surfaces from Zirconia by the Magnetron Sputtering of Different Calcium Phosphate Targets: A Comparative Study.

Authors:  Anna I Kozelskaya; Evgeny N Bolbasov; Alexey S Golovkin; Alexander I Mishanin; Alice N Viknianshchuk; Evgeny V Shesterikov; Аndrey Ashrafov; Vadim A Novikov; Alexander Y Fedotkin; Igor A Khlusov; Sergey I Tverdokhlebov
Journal:  Materials (Basel)       Date:  2018-10-11       Impact factor: 3.623

4.  Solution casting of chitosan membranes for in vitro evaluation of bioactivity.

Authors:  Ramona Lieder; Mariam Darai; Gissur Orlygsson; Olafur E Sigurjonsson
Journal:  Biol Proced Online       Date:  2013-11-06       Impact factor: 3.244

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.