This paper reports the study performed on four titanium nitride (TiN) coated prosthetic femoral heads collected at revision surgery together with patient data. Surface topology has been examined using Scanning Electron Microscopy (SEM) and elemental analysis of both coating and substrate have been evaluated using energy-dispersive X-ray spectrometry. Quantitative assessment of the surface topography is achieved using contacting profilometry. The average Ra roughness value is calculated at five different locations for each femoral head. The UHMWPE counterface worn volume has been measured directly on the acetabular components. TiN fretting and coating breakthrough occurred in two of the four components examined. In the damaged coating areas the surface profile is macroscopically saw-toothed with average tooth height 1.5 microm. The average Ra value is 0.02 microm on the undamaged surfaces and 0.37 microm on the damaged ones. Failure of the coating adhesion resulted in the release of TiN fragments and of metallic particulate from the substrate fretting corrosion and in the increase of the head surface roughness affecting counterface debris production. Our results suggest that TiN-coated titanium alloy femoral heads are inadequate in the task of resisting third body wear mechanisms in vivo.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10735467     DOI: 10.1016/s0142-9612(99)00246-x

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  19 in total

1.  Laser processed TiN reinforced Ti6Al4V composite coatings.

Authors:  Vamsi Krishna Balla; Abhimanyu Bhat; Susmita Bose; Amit Bandyopadhyay
Journal:  J Mech Behav Biomed Mater       Date:  2011-09-21

2.  A review of protein adsorption on bioceramics.

Authors:  Kefeng Wang; Changchun Zhou; Youliang Hong; Xingdong Zhang
Journal:  Interface Focus       Date:  2012-03-22       Impact factor: 3.906

Review 3.  Allergy in Total Knee Replacement. Does It Exist?: Review Article.

Authors:  Martin Faschingbauer; Lisa Renner; Friedrich Boettner
Journal:  HSS J       Date:  2016-07-22

Review 4.  [Total hip arthroplasty in young patients : Bearings and custom-made prostheses].

Authors:  C Benignus; M Morlock; J Beckmann
Journal:  Orthopade       Date:  2019-04       Impact factor: 1.087

5.  Development of superlattice CrN/NbN coatings for joint replacements deposited by high power impulse magnetron sputtering.

Authors:  Papken Ehiasarian Hovsepian; Arutiun Papken Ehiasarian; Yashodhan Purandare; Arunprabhu Arunachalam Sugumaran; Tim Marriott; Imran Khan
Journal:  J Mater Sci Mater Med       Date:  2016-08-29       Impact factor: 3.896

6.  Surface modification of 316L stainless steel with magnetron sputtered TiN/VN nanoscale multilayers for bio implant applications.

Authors:  B Subramanian; R Ananthakumar; Akira Kobayashi; M Jayachandran
Journal:  J Mater Sci Mater Med       Date:  2011-11-24       Impact factor: 3.896

7.  Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements.

Authors:  Harman Khatkar; Harry Hothi; Danielle de Villiers; Christian Lausmann; Daniel Kendoff; Thorsten Gehrke; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-10-25       Impact factor: 3.075

8.  Wear of surface engineered metal-on-metal hip prostheses.

Authors:  J Fisher; X Q Hu; T D Stewart; S Williams; J L Tipper; E Ingham; M H Stone; C Davies; P Hatto; J Bolton; M Riley; C Hardaker; G H Isaac; G Berry
Journal:  J Mater Sci Mater Med       Date:  2004-03       Impact factor: 3.896

9.  [Preclinical evaluation of coated knee implants for allergic patients].

Authors:  J Reich; L Hovy; H-L Lindenmaier; R Zeller; J Schwiesau; P Thomas; T M Grupp
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

Review 10.  [Alternative materials and solutions in total knee arthroplasty for patients with metal allergy].

Authors:  R Bader; P Bergschmidt; A Fritsche; S Ansorge; P Thomas; W Mittelmeier
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.