PIRAC Ti nitride coated Ti-6AI-4V head against UHMWPE acetabular cup-hip wear simulator study.

E Y Gutmanas1, I Gotman.   

Abstract

Wear behaviour of TiN(titanium nitride)-coated Ti and Ti-6AI-4V alloy against UHMW polyethylene was studied in hip simulation test. Ti alloys possess an excellent combination of mechanical properties and biocompatibility, however, they suffer from inadequate wear resistance. Thus, their use as articulating components of total joint replacements requires surface hardening, e.g. by TiN. Thirty-two millimetre diameter cp-Ti and Ti-6AI-4V femoral heads were coated with several micrometre thick TiN layers employing an original PIRAC nitriding method based on interaction of Ti alloy substrate with highly reactive monatomic nitrogen. The heads were tested against UHMWPE cups at 37 degrees C in Ringer's solution or in distilled water. Simulator tests were performed at peak pressures of 1.5 and 2.0 MPa in a constant rotation mode at the frequency of 1.5 Hz. The wear of UHMWPE was estimated by weight loss, and the worn metallic and polyethylene surfaces were examined in SEM. The wear rate of UHMWPE cups articulating against PIRAC coated Ti and Ti-6AI-4V after up to 4 x 10(6) cycles was significantly lower than that of UHMWPE articulating against 316L stainless steel. No delamination of TiN coatings was observed after 4 x 10(6) cycles. These results suggest that TiN PIRAC coating on Ti-6AI-4V heads could minimise the wear of total hip replacements without compromising the mechanical properties of the femoral component.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15332594     DOI: 10.1023/b:jmsm.0000021096.77850.c5

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  5 in total

1.  Potential thermal artifacts in hip joint wear simulators.

Authors:  Z Lu; H McKellop; P Liao; P Benya
Journal:  J Biomed Mater Res       Date:  1999

2.  Corrosion behavior of titanium nitride coated Ni-Ti shape memory surgical alloy.

Authors:  D Starosvetsky; I Gotman
Journal:  Biomaterials       Date:  2001-07       Impact factor: 12.479

3.  Water and bovine serum lubrication compared in simulator PTFE/CoCr wear model.

Authors:  V D Good; I C Clarke; L Anissian
Journal:  J Biomed Mater Res       Date:  1996

4.  Corrosion behavior of PIRAC nitrided Ti-6Al-4V surgical alloy.

Authors:  D Starosvetsky; A Shenhar; I Gotman
Journal:  J Mater Sci Mater Med       Date:  2001-02       Impact factor: 3.896

5.  Titanium nitride ceramic film against polyethylene. A 48 million cycle wear test.

Authors:  M J Pappas; G Makris; F F Buechel
Journal:  Clin Orthop Relat Res       Date:  1995-08       Impact factor: 4.176

  5 in total
  4 in total

1.  Laser processed TiN reinforced Ti6Al4V composite coatings.

Authors:  Vamsi Krishna Balla; Abhimanyu Bhat; Susmita Bose; Amit Bandyopadhyay
Journal:  J Mech Behav Biomed Mater       Date:  2011-09-21

2.  Retrieval analysis of ceramic-coated metal-on-polyethylene total hip replacements.

Authors:  Harman Khatkar; Harry Hothi; Danielle de Villiers; Christian Lausmann; Daniel Kendoff; Thorsten Gehrke; John Skinner; Alister Hart
Journal:  Int Orthop       Date:  2016-10-25       Impact factor: 3.075

3.  Nanostructured diamond coatings for orthopaedic applications.

Authors:  S A Catledge; V Thomas; Y K Vohra
Journal:  Woodhead Publ Ser Biomater       Date:  2013

Review 4.  Titanium-Nitride Coating of Orthopaedic Implants: A Review of the Literature.

Authors:  Ruud P van Hove; Inger N Sierevelt; Barend J van Royen; Peter A Nolte
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

  4 in total