Literature DB >> 3558450

Wear-accelerated corrosion of Ti-6Al-4V and nitrogen-ion-implanted Ti-6Al-4V: mechanisms and influence of fixed-stress magnitude.

R A Buchanan, E D Rigney, J M Williams.   

Abstract

Wear-accelerated corrosion rates at constant anodic potentials were evaluated for unimplanted and nitrogen-ion-implanted surgical Ti-6Al-4V while wearing against ultrahigh-molecular-weight polyethylene at stress levels up to 6.90 MPa (1000 psi). The ion implantation processing was found to reduce the wear corrosion rates in both saline and serum solutions at all applied stress levels. During wear testing, all of the ion-implanted surfaces remained visually unchanged from the polished condition. However, many of the unimplanted surfaces developed damage zones characterized by wear tracks and black wear debris. A surface-damage mechanism is proposed and discussed which involves disruption of the Ti-6Al-4V protective oxide film, subsequent entrapment of oxide particles in the polyethylene, then self-perpetuating damage due to the abrasive action of the embedded particles.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3558450     DOI: 10.1002/jbm.820210309

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  8 in total

1.  Laser processed TiN reinforced Ti6Al4V composite coatings.

Authors:  Vamsi Krishna Balla; Abhimanyu Bhat; Susmita Bose; Amit Bandyopadhyay
Journal:  J Mech Behav Biomed Mater       Date:  2011-09-21

Review 2.  Allergy in Total Knee Replacement. Does It Exist?: Review Article.

Authors:  Martin Faschingbauer; Lisa Renner; Friedrich Boettner
Journal:  HSS J       Date:  2016-07-22

3.  Early Outcomes of an Alternative Bearing Surface in Primary Total Knee Arthroplasty in Patients with Self-reported Metal Allergy.

Authors:  Jesua I Law; Micael J Morris; Jason M Hurst; Keith R Berend; Adolph V Lombardi; David A Crawford
Journal:  Arthroplast Today       Date:  2020-08-22

4.  In vivo evaluation of bone tissue behavior on ion implanted surfaces.

Authors:  M Bosetti; A Massè; E Tobin; M Cannas
Journal:  J Mater Sci Mater Med       Date:  2001-05       Impact factor: 3.896

Review 5.  [Alternative materials and solutions in total knee arthroplasty for patients with metal allergy].

Authors:  R Bader; P Bergschmidt; A Fritsche; S Ansorge; P Thomas; W Mittelmeier
Journal:  Orthopade       Date:  2008-02       Impact factor: 1.087

6.  Laser surface processing of Ti6Al4V in gaseous nitrogen: corrosion performance in physiological solution.

Authors:  Raghuvir Singh; S Ghosh Chowdhury; S K Tiwari; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2007-10-04       Impact factor: 3.896

7.  Bioactive and antimicrobial macro-/micro-nanoporous selective laser melted Ti-6Al-4V alloy for biomedical applications.

Authors:  Archana Rajendran; Deepak K Pattanayak
Journal:  Heliyon       Date:  2022-03-15

8.  Oral factors affecting titanium elution and corrosion: an in vitro study using simulated body fluid.

Authors:  Hideki Suito; Yuki Iwawaki; Takaharu Goto; Yoritoki Tomotake; Tetsuo Ichikawa
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.