Literature DB >> 22285714

The accuracy and repeatability of an automatic 2D-3D fluoroscopic image-model registration technique for determining shoulder joint kinematics.

Zhonglin Zhu1, Daniel F Massimini, Guangzhi Wang, Jon J P Warner, Guoan Li.   

Abstract

Fluoroscopic imaging, using single plane or dual plane images, has grown in popularity to measure dynamic in vivo human shoulder joint kinematics. However, no study has quantified the difference in spatial positional accuracy between single and dual plane image-model registration applied to the shoulder joint. In this paper, an automatic 2D-3D image-model registration technique was validated for accuracy and repeatability with single and dual plane fluoroscopic images. Accuracy was assessed in a cadaver model, kinematics found using the automatic registration technique were compared to those found using radiostereometric analysis. The in vivo repeatability of the automatic registration technique was assessed during the dynamic abduction motion of four human subjects. The in vitro data indicated that the error in spatial positional accuracy of the humerus and the scapula was less than 0.30mm in translation and less than 0.58° in rotation using dual plane images. Single plane accuracy was satisfactory for in-plane motion variables, but out-of-plane motion variables on average were approximately 8 times less accurate. The in vivo test indicated that the repeatability of the automatic 2D-3D image-model registration was 0.50mm in translation and 1.04° in rotation using dual images. For a single plane technique, the repeatability was 3.31mm in translation and 2.46° in rotation for measuring shoulder joint kinematics. The data demonstrate that accurate and repeatable shoulder joint kinematics can be obtained using dual plane fluoroscopic images with an automatic 2D-3D image-model registration technique; and that out-of-plane motion variables are less accurate than in-plane motion variables using a single plane technique.
Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22285714     DOI: 10.1016/j.medengphy.2011.12.021

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  18 in total

1.  Measuring Three-Dimensional Thorax Motion Via Biplane Radiographic Imaging: Technique and Preliminary Results.

Authors:  Timothy G Baumer; Joshua W Giles; Anne Drake; Roger Zauel; Michael J Bey
Journal:  J Biomech Eng       Date:  2016-01       Impact factor: 2.097

2.  Kinematic Accuracy in Tracking Total Wrist Arthroplasty with Biplane Videoradiography using a CT-generated Model.

Authors:  Bardiya Akhbari; Amy Morton; Douglas Moore; Arnold-Peter C Weiss; Scott W Wolfe; Joseph Crisco
Journal:  J Biomech Eng       Date:  2019-02-07       Impact factor: 2.097

3.  In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

Authors:  Luca Tersi; Arnaud Barré; Silvia Fantozzi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-11-11       Impact factor: 2.602

4.  Soft tissue artifact causes underestimation of hip joint kinematics and kinetics in a rigid-body musculoskeletal model.

Authors:  Niccolo M Fiorentino; Penny R Atkins; Michael J Kutschke; K Bo Foreman; Andrew E Anderson
Journal:  J Biomech       Date:  2020-06-13       Impact factor: 2.712

5.  Marker-free motion correction in weight-bearing cone-beam CT of the knee joint.

Authors:  M Berger; K Müller; A Aichert; M Unberath; J Thies; J-H Choi; R Fahrig; A Maier
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

6.  Validation of single-plane fluoroscopy and 2D/3D shape-matching for quantifying shoulder complex kinematics.

Authors:  Rebekah L Lawrence; Arin M Ellingson; Paula M Ludewig
Journal:  Med Eng Phys       Date:  2017-12-08       Impact factor: 2.242

7.  MRI vs CT-based 2D-3D auto-registration accuracy for quantifying shoulder motion using biplane video-radiography.

Authors:  Mohsen Akbari-Shandiz; Rebekah L Lawrence; Arin M Ellingson; Casey P Johnson; Kristin D Zhao; Paula M Ludewig
Journal:  J Biomech       Date:  2018-09-29       Impact factor: 2.712

8.  Validation of imaging-based quantification of glenohumeral joint kinematics using an unmodified clinical biplane fluoroscopy system.

Authors:  Joseph D Mozingo; Mohsen Akbari Shandiz; Felicia M Marquez; Beth A Schueler; David R Holmes; Cynthia H McCollough; Kristin D Zhao
Journal:  J Biomech       Date:  2018-02-13       Impact factor: 2.712

9.  Robust 3D-2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation.

Authors:  Yoshito Otake; Adam S Wang; J Webster Stayman; Ali Uneri; Gerhard Kleinszig; Sebastian Vogt; A Jay Khanna; Ziya L Gokaslan; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2013-11-18       Impact factor: 3.609

10.  Comparison of glenohumeral joint kinematics between manual wheelchair tasks and implications on the subacromial space: A biplane fluoroscopy study.

Authors:  Joseph D Mozingo; Mohsen Akbari-Shandiz; Meegan G Van Straaten; Naveen S Murthy; Beth A Schueler; David R Holmes; Cynthia H McCollough; Kristin D Zhao
Journal:  J Electromyogr Kinesiol       Date:  2019-08-23       Impact factor: 2.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.