Literature DB >> 32636003

Soft tissue artifact causes underestimation of hip joint kinematics and kinetics in a rigid-body musculoskeletal model.

Niccolo M Fiorentino1, Penny R Atkins2, Michael J Kutschke3, K Bo Foreman4, Andrew E Anderson5.   

Abstract

Rigid body musculoskeletal models have been applied to study kinematics, moments, muscle forces, and joint reaction forces in the hip. Most often, models are driven with segment motions calculated through optical tracking of markers adhered to the skin. One limitation of optical tracking is soft tissue artifact (STA), which occurs due to motion of the skin surface relative to the underlying skeleton. The purpose of this study was to quantify differences in musculoskeletal model outputs when tracking body segment positions with skin markers as compared to bony landmarks measured by direct imaging of bone motion with dual fluoroscopy (DF). Eleven asymptomatic participants with normally developed hip anatomy were imaged with DF during level treadmill walking at a self-selected speed. Hip joint kinematics and kinetics were generated using inverse kinematics, inverse dynamics, static optimization and joint reaction force analysis. The effect of STA was assessed by comparing the difference in estimates from simulations based on skin marker positions (SM) versus virtual markers on bony landmarks from DF. While patterns were similar, STA caused underestimation of kinematics, range of motion (ROM), moments, and reaction forces at the hip, including flexion-extension ROM, maximum internal rotation joint moment and peak joint reaction force magnitude. Still, kinetic differences were relatively small, and thus they may not be relevant nor clinically meaningful.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Gait; Motion capture; Musculoskeletal model; Simulation; X-ray

Mesh:

Year:  2020        PMID: 32636003      PMCID: PMC7405358          DOI: 10.1016/j.jbiomech.2020.109890

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  42 in total

1.  Design and responses of Butterworth and critically damped digital filters.

Authors:  D Gordon E Robertson; James J Dowling
Journal:  J Electromyogr Kinesiol       Date:  2003-12       Impact factor: 2.368

2.  Walking patterns and hip contact forces in patients with hip dysplasia.

Authors:  Ole Skalshøi; Christian Hauskov Iversen; Dennis Brandborg Nielsen; Julie Jacobsen; Inger Mechlenburg; Kjeld Søballe; Henrik Sørensen
Journal:  Gait Posture       Date:  2015-08-29       Impact factor: 2.840

3.  Biomechanical ToolKit: Open-source framework to visualize and process biomechanical data.

Authors:  Arnaud Barre; Stéphane Armand
Journal:  Comput Methods Programs Biomed       Date:  2014-01-21       Impact factor: 5.428

4.  A model of the soft tissue artefact rigid component.

Authors:  V Camomilla; T Bonci; R Dumas; L Chèze; A Cappozzo
Journal:  J Biomech       Date:  2015-06-05       Impact factor: 2.712

5.  Standardization proposal of soft tissue artefact description for data sharing in human motion measurements.

Authors:  Andrea Cereatti; Tecla Bonci; Massoud Akbarshahi; Kamiar Aminian; Arnaud Barré; Mickael Begon; Daniel L Benoit; Caecilia Charbonnier; Fabien Dal Maso; Silvia Fantozzi; Cheng-Chung Lin; Tung-Wu Lu; Marcus G Pandy; Rita Stagni; Antonie J van den Bogert; Valentina Camomilla
Journal:  J Biomech       Date:  2017-02-21       Impact factor: 2.712

6.  Sensitivity of subject-specific models to errors in musculo-skeletal geometry.

Authors:  V Carbone; M M van der Krogt; H F J M Koopman; N Verdonschot
Journal:  J Biomech       Date:  2012-08-04       Impact factor: 2.712

7.  Compressive tibiofemoral force during crouch gait.

Authors:  Katherine M Steele; Matthew S Demers; Michael H Schwartz; Scott L Delp
Journal:  Gait Posture       Date:  2011-12-27       Impact factor: 2.840

8.  Subject-specific hip geometry affects predicted hip joint contact forces during gait.

Authors:  G Lenaerts; F De Groote; B Demeulenaere; M Mulier; G Van der Perre; A Spaepen; I Jonkers
Journal:  J Biomech       Date:  2008-03-17       Impact factor: 2.712

Review 9.  The role of biomechanics and inflammation in cartilage injury and repair.

Authors:  Farshid Guilak; Beverley Fermor; Francis J Keefe; Virginia B Kraus; Steven A Olson; David S Pisetsky; Lori A Setton; J Brice Weinberg
Journal:  Clin Orthop Relat Res       Date:  2004-06       Impact factor: 4.176

Review 10.  Quantification of soft tissue artifact in lower limb human motion analysis: a systematic review.

Authors:  Alana Peters; Brook Galna; Morgan Sangeux; Meg Morris; Richard Baker
Journal:  Gait Posture       Date:  2009-10-23       Impact factor: 2.840

View more
  6 in total

1.  Does Femoral Head Translation Vary by Sex and Side in Asymptomatic Hips During a Weightbearing Apprehension Test?

Authors:  Ethan Ruh; Camille Johnson; Naomi Frankston; Shaquille Charles; William Anderst; Michael McClincy
Journal:  Clin Orthop Relat Res       Date:  2022-02-23       Impact factor: 4.755

Review 2.  A review of musculoskeletal modelling of human locomotion.

Authors:  Adam D Sylvester; Steven G Lautzenheiser; Patricia Ann Kramer
Journal:  Interface Focus       Date:  2021-08-13       Impact factor: 4.661

3.  Conclusion or Illusion: Quantifying Uncertainty in Inverse Analyses From Marker-Based Motion Capture due to Errors in Marker Registration and Model Scaling.

Authors:  Thomas K Uchida; Ajay Seth
Journal:  Front Bioeng Biotechnol       Date:  2022-05-25

4.  Synthesising 2D Video from 3D Motion Data for Machine Learning Applications.

Authors:  Marion Mundt; Henrike Oberlack; Molly Goldacre; Julia Powles; Johannes Funken; Corey Morris; Wolfgang Potthast; Jacqueline Alderson
Journal:  Sensors (Basel)       Date:  2022-08-29       Impact factor: 3.847

5.  In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy.

Authors:  Penny R Atkins; Niccolo M Fiorentino; Andrew E Anderson
Journal:  J Vis Exp       Date:  2021-07-02       Impact factor: 1.424

6.  Muscle forces and the demands of human walking.

Authors:  Adam D Sylvester; Steven G Lautzenheiser; Patricia Ann Kramer
Journal:  Biol Open       Date:  2021-07-19       Impact factor: 2.422

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.