Literature DB >> 29478696

Validation of imaging-based quantification of glenohumeral joint kinematics using an unmodified clinical biplane fluoroscopy system.

Joseph D Mozingo1, Mohsen Akbari Shandiz2, Felicia M Marquez2, Beth A Schueler3, David R Holmes4, Cynthia H McCollough3, Kristin D Zhao5.   

Abstract

Model-based tracking, using CT and biplane fluoroscopy, allows highly accurate quantification of glenohumeral motion and changes in the subacromial space. Previous investigators have used custom-built biplane fluoroscopes designed specifically for kinematic applications, which are available at few institutions and require FDA approval prior to clinical use. The aim of this study was to demonstrate the utility of an off-the-shelf clinical biplane fluoroscope for kinematic applications by validating model-based tracking for measurement of glenohumeral motion using an unmodified clinical system. Biplane images of each shoulder of a cadaver torso were acquired at various joint positions and during simulated movements along anatomical planes of motion. The pose of each humerus and scapula was determined using model-based tracking and compared to a bead-based gold standard. Error due to a temporal-offset between corresponding biplane images, characteristic of clinical biplane systems, was determined by comparison of measured and known relative position of 2 bead clusters of a phantom that was imaged while moved throughout the fluoroscopy image volume. Model-based tracking had global kinematic mean absolute errors of 0.27 mm and 0.29° (static), and 0.22-0.32 mm and 0.12-0.45° (dynamic). Glenohumeral mean absolute errors were 0.39 mm and 0.45° (static), and 0.36-0.42 mm and 0.41-0.48° (dynamic). The temporal-offset was predicted to add errors of 0.06-0.85 mm and 0.05-0.28° for cadaveric trials for the speeds examined. For defined speeds, sub-millimeter and sub-degree kinematic accuracy and precision were achieved using an unmodified clinical biplane fluoroscope for quantification of glenohumeral motion.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Accuracy; Clinical biplane; Computed tomography; Fluoroscopy; Kinematics; Model-based tracking; Radiostereometric analysis; Shoulder; Validation

Mesh:

Year:  2018        PMID: 29478696      PMCID: PMC5878125          DOI: 10.1016/j.jbiomech.2018.02.012

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  21 in total

1.  Kinematics of shoulder abduction in the scapular plane. On the influence of abduction velocity and external load.

Authors:  I Michiels; J Grevenstein
Journal:  Clin Biomech (Bristol, Avon)       Date:  1995-04       Impact factor: 2.063

2.  The effects of arm elevation on the 3-dimensional acromiohumeral distance: a biplane fluoroscopy study with normative data.

Authors:  J Erik Giphart; Olivier A J van der Meijden; Peter J Millett
Journal:  J Shoulder Elbow Surg       Date:  2012-02-22       Impact factor: 3.019

Review 3.  Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.

Authors:  G Selvik
Journal:  Acta Orthop Scand Suppl       Date:  1989

4.  Comparison of glenohumeral motion using different rotation sequences.

Authors:  Vandana Phadke; Jonathan P Braman; Robert F LaPrade; Paula M Ludewig
Journal:  J Biomech       Date:  2010-12-24       Impact factor: 2.712

5.  3-D scapular kinematics during arm elevation: effect of motion velocity.

Authors:  F Fayad; G Hoffmann; S Hanneton; C Yazbeck; M M Lefevre-Colau; S Poiraudeau; M Revel; A Roby-Brami
Journal:  Clin Biomech (Bristol, Avon)       Date:  2006-06-13       Impact factor: 2.063

6.  Validation of a new model-based tracking technique for measuring three-dimensional, in vivo glenohumeral joint kinematics.

Authors:  Michael J Bey; Roger Zauel; Stephanie K Brock; Scott Tashman
Journal:  J Biomech Eng       Date:  2006-08       Impact factor: 2.097

7.  X-ray reconstruction of moving morphology (XROMM): precision, accuracy and applications in comparative biomechanics research.

Authors:  Elizabeth L Brainerd; David B Baier; Stephen M Gatesy; Tyson L Hedrick; Keith A Metzger; Susannah L Gilbert; Joseph J Crisco
Journal:  J Exp Zool A Ecol Genet Physiol       Date:  2010-06-01

8.  Static and dynamic error of a biplanar videoradiography system using marker-based and markerless tracking techniques.

Authors:  Daniel L Miranda; Joel B Schwartz; Andrew C Loomis; Elizabeth L Brainerd; Braden C Fleming; Joseph J Crisco
Journal:  J Biomech Eng       Date:  2011-12       Impact factor: 2.097

Review 9.  Shoulder impingement revisited: evolution of diagnostic understanding in orthopedic surgery and physical therapy.

Authors:  Jonathan P Braman; Kristin D Zhao; Rebekah L Lawrence; Alicia K Harrison; Paula M Ludewig
Journal:  Med Biol Eng Comput       Date:  2013-04-10       Impact factor: 2.602

10.  Effects of Rotator Cuff Pathology and Physical Therapy on In Vivo Shoulder Motion and Clinical Outcomes in Patients With a Symptomatic Full-Thickness Rotator Cuff Tear.

Authors:  Timothy G Baumer; Derek Chan; Veronica Mende; Jack Dischler; Roger Zauel; Marnix van Holsbeeck; Daniel S Siegal; George Divine; Vasilios Moutzouros; Michael J Bey
Journal:  Orthop J Sports Med       Date:  2016-09-26
View more
  3 in total

1.  Shoulder mechanical impingement risk associated with manual wheelchair tasks in individuals with spinal cord injury.

Authors:  Joseph D Mozingo; Mohsen Akbari-Shandiz; Naveen S Murthy; Meegan G Van Straaten; Beth A Schueler; David R Holmes; Cynthia H McCollough; Kristin D Zhao
Journal:  Clin Biomech (Bristol, Avon)       Date:  2019-10-20       Impact factor: 2.063

2.  Comparison of glenohumeral joint kinematics between manual wheelchair tasks and implications on the subacromial space: A biplane fluoroscopy study.

Authors:  Joseph D Mozingo; Mohsen Akbari-Shandiz; Meegan G Van Straaten; Naveen S Murthy; Beth A Schueler; David R Holmes; Cynthia H McCollough; Kristin D Zhao
Journal:  J Electromyogr Kinesiol       Date:  2019-08-23       Impact factor: 2.368

3.  Biplanar Videoradiography to Study the Wrist and Distal Radioulnar Joints.

Authors:  Bardiya Akhbari; Amy M Morton; Douglas C Moore; Joseph J Crisco
Journal:  J Vis Exp       Date:  2021-02-04       Impact factor: 1.355

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.