Literature DB >> 23995875

Displacement of the lumpectomy cavity defined by surgical clips and seroma based on 4D-CT scan for external-beam partial breast irradiation after breast-conserving surgery: a comparative study.

Y Ding1, J Li, W Wang, S Wang, T Fan, M Xu, Q Shao, Z Ma.   

Abstract

OBJECTIVE: To compare the displacements of the lumpectomy cavity delineated by the surgical clips and the seroma based on four-dimensional CT (4D-CT) for external-beam partial breast irradiation (EB-PBI) after breast-conserving surgery (BCS).
METHODS: 14 breast cancer patients after BCS were recruited for EB-PBI and undertook 4D-CT simulation. On the 10 sets of the 4D-CT images, all the surgical clips in the cavity were delineated. The gross tumour volume (GTV) formed by the clips, the seroma, and both the clips and the seroma were defined as GTVc, GTVs and GTVc+s, respectively. The displacements of the centre of mass (COM) of the clips, GTVc, GTVs, GTVc+s and the selected clips in the three-dimensional (3D) directions were recorded and compared.
RESULTS: In the left-right, anterior-posterior and superior-inferior directions, the displacements were 2.20, 1.80 and 2.70 mm for the clip COM; 0.90, 1.05 and 1.20 mm for GTVc; 0.80, 1.05 and 0.80 mm for GTVs; and 0.90, 1.20 and 1.40 mm for GTVc+s, respectively. In the 3D directions, the displacements of the clip COM were greater than the GTVc, GTVs, GTVc+s, and the displacements of the clip COM, GTVc+s, GTVc and GTVs were significantly greater than the displacements of the selected clips (p<0.05).
CONCLUSION: The displacements of the clip COM were greater than that of the GTVc, GTVs, GTVc+s and the four selected clips. The optimal internal target volume should be defined based on the boundary displacements. ADVANCES IN KNOWLEDGE: When the GTV was delineated using the clips and/or the seroma, there was displacement difference between the lumpectomy cavity centre and the boundary for the EB-PBI. The optimal internal target volume should be defined based on the boundary displacements of the lumpectomy cavity.

Entities:  

Mesh:

Year:  2013        PMID: 23995875      PMCID: PMC3798338          DOI: 10.1259/bjr.20130416

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  26 in total

Review 1.  Accelerated partial breast irradiation as a part of breast conservation therapy.

Authors:  Douglas W Arthur; Frank A Vicini
Journal:  J Clin Oncol       Date:  2005-03-10       Impact factor: 44.544

2.  Active breathing control (ABC): determination and reduction of breathing-induced organ motion in the chest.

Authors:  Bernd Gagel; Cengiz Demirel; Aline Kientopf; Michael Pinkawa; Marc Piroth; Sven Stanzel; Christian Breuer; Branka Asadpour; Thomas Jansen; Richard Holy; Joachim E Wildberger; Michael J Eble
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-29       Impact factor: 7.038

3.  Consistency in seroma contouring for partial breast radiotherapy: impact of guidelines.

Authors:  Elaine K Wong; Pauline T Truong; Hosam A Kader; Alan M Nichol; Lee Salter; Ross Petersen; Elaine S Wai; Lorna Weir; Ivo A Olivotto
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-10-01       Impact factor: 7.038

4.  Radiotherapy after breast-conserving surgery in small breast carcinoma: long-term results of a randomized trial.

Authors:  U Veronesi; E Marubini; L Mariani; V Galimberti; A Luini; P Veronesi; B Salvadori; R Zucali
Journal:  Ann Oncol       Date:  2001-07       Impact factor: 32.976

5.  10-Year results after sector resection with or without postoperative radiotherapy for stage I breast cancer: a randomized trial.

Authors:  G Liljegren; L Holmberg; J Bergh; A Lindgren; L Tabár; H Nordgren; H O Adami
Journal:  J Clin Oncol       Date:  1999-08       Impact factor: 44.544

6.  Tumour bed delineation for partial breast/breast boost radiotherapy: what is the optimal number of implanted markers?

Authors:  Anna Nm Kirby; Rajesh Jena; Emma J Harris; Phil M Evans; Clare Crowley; Deborah L Gregory; Charlotte E Coles
Journal:  Radiother Oncol       Date:  2013-03-13       Impact factor: 6.280

7.  Assessment of the residual error in soft tissue setup in patients undergoing partial breast irradiation: results of a prospective study using cone-beam computed tomography.

Authors:  Toyosi Fatunase; Zhiheng Wang; Sua Yoo; Jessica L Hubbs; Robert G Prosnitz; Fang-Fang Yin; Lawrence B Marks
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-09-24       Impact factor: 7.038

8.  When is CT-based postoperative seroma most useful to plan partial breast radiotherapy? Evaluation of clinical factors affecting seroma volume and clarity.

Authors:  Hosam A Kader; Pauline T Truong; Rohit Pai; Miguel Panades; Stuart Jones; Will Ansbacher; Ivo A Olivotto
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-04-12       Impact factor: 7.038

9.  Target volume delineation for partial breast radiotherapy planning: clinical characteristics associated with low interobserver concordance.

Authors:  Ross P Petersen; Pauline T Truong; Hosam A Kader; Eric Berthelet; Junella C Lee; Michelle L Hilts; Adam S Kader; Wayne A Beckham; Ivo A Olivotto
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-09-01       Impact factor: 7.038

10.  Twenty-year follow-up of a randomized trial comparing total mastectomy, lumpectomy, and lumpectomy plus irradiation for the treatment of invasive breast cancer.

Authors:  Bernard Fisher; Stewart Anderson; John Bryant; Richard G Margolese; Melvin Deutsch; Edwin R Fisher; Jong-Hyeon Jeong; Norman Wolmark
Journal:  N Engl J Med       Date:  2002-10-17       Impact factor: 91.245

View more
  4 in total

1.  Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation.

Authors:  Bing Guo; Jianbin Li; Wei Wang; Min Xu; Qian Shao; Yingjie Zhang; Chaoqian Liang; Yanluan Guo
Journal:  Radiat Oncol       Date:  2015-03-13       Impact factor: 3.481

2.  Setup Error Assessment and Correction in Planar kV Image- Versus Cone Beam CT Image-Guided Radiation Therapy: A Clinical Study of Early Breast Cancer Treated With External Beam Partial Breast Irradiation.

Authors:  Wei Wang; Ting Yu; Min Xu; Qian Shao; Yingjie Zhang; Jianbin Li
Journal:  Technol Cancer Res Treat       Date:  2019 Jan-Dec

3.  Dosimetric comparison between three- and four-dimensional computerised tomography radiotherapy for breast cancer.

Authors:  Yanli Yan; Zhou Lu; Zi Liu; Wei Luo; Shuai Shao; Li Tan; Xiaowei Ma; Jiaxin Liu; Emmanuel Kwateng Drokow; Juan Ren
Journal:  Oncol Lett       Date:  2019-06-12       Impact factor: 2.967

4.  A comparative study on the volume and localization of the internal gross target volume defined using the seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation after breast conserving surgery.

Authors:  Yun Ding; Jianbin Li; Wei Wang; Suzhen Wang; Jinzhi Wang; Zhifang Ma; Qian Shao; Min Xu
Journal:  Radiat Oncol       Date:  2014-03-19       Impact factor: 3.481

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.