Literature DB >> 19545816

Evaluation of image quality after implantation of 2 diffractive multifocal intraocular lens models.

Alfredo Castillo-Gómez1, David Carmona-González, José María Martínez-de-la-Casa, Carlos Palomino-Bautista, Julián García-Feijoo.   

Abstract

PURPOSE: To compare the visual quality after implantation of multifocal intraocular lenses (IOLs).
SETTING: Departments of Ophthalmology, Hospital Quirón and Hospital Clínico San Carlos, Madrid, Spain.
METHODS: In a prospective nonrandomized consecutive trial, patients had bilateral implantation of Acri.LISA 366D (Group A) or Tecnis ZM900 (Group B) multifocal IOLs. One eye of each patient was included in the study. Three months postoperatively, uncorrected and corrected distance and near visual acuities, pupil diameter, and refraction were assessed. The modulation transfer function (MTF), point-spread function (PSF), and light scattering were calculated using the double-pass Optical Quality Analysis System for distance vision with a 4.0 mm pupil diameter.
RESULTS: Each IOL group comprised 20 patients. No statistically significant differences were found between the 2 groups in postoperative mean spherical equivalent or mean monocular corrected distance or near visual acuity. The PSF variables were slightly lower in Group B, although the difference between groups was not statistically significant. The MTF parameters (double-pass value at 100%, 20%, and 9% contrast) were slightly higher in Group A (P = .07, P = .04, and P = .09, respectively). The mean objective scatter index was 1.83 +/- 0.91 (SD) in Group A and 2.00 +/- 0.74 in Group B (P = .43).
CONCLUSIONS: Both diffractive multifocal IOLs improved functional visual capacity at distance and near. Although the visual quality variables were slightly better in Group A than in Group B, the differences were not statistically significant.

Entities:  

Mesh:

Year:  2009        PMID: 19545816     DOI: 10.1016/j.jcrs.2009.02.024

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  7 in total

1.  Objective evaluation of through-focus optical performance of presbyopia-correcting intraocular lenses using an optical bench system.

Authors:  Myoung Joon Kim; Len Zheleznyak; Scott Macrae; Hungwon Tchah; Geunyoung Yoon
Journal:  J Cataract Refract Surg       Date:  2011-07       Impact factor: 3.351

2.  Comparison of through-focus image quality across five presbyopia-correcting intraocular lenses (an American Ophthalmological Society thesis).

Authors:  Jay S Pepose; Daozhi Wang; Griffith E Altmann
Journal:  Trans Am Ophthalmol Soc       Date:  2011-12

3.  Assessment of Optical Quality at Different Contrast Levels in Pseudophakic Eyes.

Authors:  Chang Won Park; Hyojin Kim; Choun-Ki Joo
Journal:  J Ophthalmol       Date:  2016-01-28       Impact factor: 1.909

4.  In vitro optical quality measurements of three intraocular lens models having identical platform.

Authors:  Hyeck Soo Son; Tamer Tandogan; Stephanie Liebing; Patrick Merz; Chul Young Choi; Ramin Khoramnia; Gerd U Auffarth
Journal:  BMC Ophthalmol       Date:  2017-06-29       Impact factor: 2.209

5.  A comparison of mesopic visual acuity and objective visual quality following cataract surgery with hydrophobic acrylic intraocular lenses.

Authors:  George Hh Beiko; Miso Gostimir; Lila Haj-Ahmad
Journal:  Clin Ophthalmol       Date:  2017-04-07

6.  Objective Quantification of Image Quality and Optical Scatter Before and After Nd:YAG Capsulotomy Using a Double-Pass Technique.

Authors:  Abu-Bakar Zafar; Richard C Chu; Miranda N Bishara; Mujtaba A Qazi; Ashraf M Mahmoud; Jay S Pepose
Journal:  Clin Ophthalmol       Date:  2020-05-26

7.  Ray propagation imaging and optical quality evaluation of different intraocular lens models.

Authors:  Hyeck Soo Son; Grzegorz Labuz; Ramin Khoramnia; Patrick Merz; Timur M Yildirim; Gerd U Auffarth
Journal:  PLoS One       Date:  2020-02-04       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.