Isodose curve mappings measured while undergoing rotation for quality assurance testing of a 137Cs irradiator.

Samuel L Brady1, Terry T Yoshizumi, Colin Anderson-Evans, Giao Nguyen.   

Abstract

To enable accurate and reproducible dosimetry for biological sample irradiation in a 137Cs irradiator, routine quality assurance of the dose rate and isodose distributions should be considered. Our previous work demonstrated a means for accurate dose rate quality assurance and for quality assurance of isodose distributions of non-rotational samples. This work presents a means to accurately and cost effectively measure dose distributions within a 137Cs irradiator using rotational geometry, which geometry represent a more typical use of these irradiators. A simple apparatus was developed to hold radiochromic film and was constructed of polymethyl methacrylate. The rotational quality assurance device allowed the comparison of measured radiochromic film vs. manufacturer provided isodose distributions. A good agreement was discovered between the two data sets along the central vertical axis of rotation in the 137Cs irradiator, but a 40-50% smaller 100% isodose region in the horizontal direction. These findings may lead to limiting the overall size of a sample capable of being uniformly irradiated by the 137Cs irradiator at this research institution. The authors propose the construction and use of a simple rotational quality assurance device for routine quality assurance of 137Cs irradiators.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22249472      PMCID: PMC3319067          DOI: 10.1097/HP.0b013e31823c9671

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  6 in total

1.  Precise radiochromic film dosimetry using a flat-bed document scanner.

Authors:  Slobodan Devic; Jan Seuntjens; Edwin Sham; Ervin B Podgorsak; C Ross Schmidtlein; Assen S Kirov; Christopher G Soares
Journal:  Med Phys       Date:  2005-07       Impact factor: 4.071

2.  Post-irradiation colouration of Gafchromic EBT radiochromic film.

Authors:  Tsang Cheung; Martin J Butson; Peter K N Yu
Journal:  Phys Med Biol       Date:  2005-10-04       Impact factor: 3.609

3.  Absorption spectroscopy of EBT model GAFCHROMIC film.

Authors:  Slobodan Devic; Nada Tomic; Zhiyu Pang; Jan Seuntjens; Ervin B Podgorsak; Christopher G Soares
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

4.  Optimizing the dynamic range extension of a radiochromic film dosimetry system.

Authors:  Slobodan Devic; Nada Tomic; Christopher G Soares; Ervin B Podgorsak
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

5.  Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.

Authors:  B C Ferreira; M C Lopes; M Capela
Journal:  Phys Med Biol       Date:  2009-01-23       Impact factor: 3.609

6.  Characterization of a 137Cs irradiator from a new perspective with modern dosimetric tools.

Authors:  Samuel L Brady; Greta Toncheva; Mark W Dewhirst; Terry T Yoshizumi
Journal:  Health Phys       Date:  2009-09       Impact factor: 1.316

  6 in total
  2 in total

1.  Dosimetry Formalism and Implementation of a Homogenous Irradiation Protocol to Improve the Accuracy of Small Animal Whole-Body Irradiation Using a 137Cs Irradiator.

Authors:  N Patrik Brodin; Yong Chen; Ravindra Yaparpalvi; Chandan Guha; Wolfgang A Tomé
Journal:  Health Phys       Date:  2016-02       Impact factor: 1.316

2.  Study logistics that can impact medical countermeasure efficacy testing in mouse models of radiation injury.

Authors:  Andrea L DiCarlo; Zulmarie Perez Horta; Carmen I Rios; Merriline M Satyamitra; Lanyn P Taliaferro; David R Cassatt
Journal:  Int J Radiat Biol       Date:  2020-09-24       Impact factor: 2.694

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.