Optimizing the dynamic range extension of a radiochromic film dosimetry system.

Slobodan Devic1, Nada Tomic, Christopher G Soares, Ervin B Podgorsak.   

Abstract

The authors present a radiochromic film dosimetry protocol for a multicolor channel radiochromic film dosimetry system consisting of the external beam therapy (EBT) model GAFCHROMIC film and the Epson Expression 1680 flat-bed document scanner. Instead of extracting only the red color channel, the authors are using all three color channels in the absorption spectrum of the EBT film to extend the dynamic dose range of the radiochromic film dosimetry system. By optimizing the dose range for each color channel, they obtained a system that has both precision and accuracy below 1.5%, and the optimized ranges are 0-4 Gy for the red channel, 4-50 Gy for the green channel, and above 50 Gy for the blue channel.

Entities:  

Mesh:

Year:  2009        PMID: 19291981     DOI: 10.1118/1.3049597

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  18 in total

1.  Implementation of radiochromic film dosimetry protocol for volumetric dose assessments to various organs during diagnostic CT procedures.

Authors:  Samuel Brady; Terry Yoshizumi; Greta Toncheva; Donald Frus
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

2.  Evaluation of the absorbed dose to the breast using radiochromic film in a dedicated CT mammotomography system employing a quasi-monochromatic x-ray beam.

Authors:  Dominic J Crotty; Samuel L Brady; D'Vone C Jackson; Greta I Toncheva; Colin E Anderson; Terry T Yoshizumi; Martin P Tornai
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

3.  Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems.

Authors:  Stephen J Gardner; Matthew T Studenski; Tawfik Giaddui; Yunfeng Cui; James Galvin; Yan Yu; Ying Xiao
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

4.  Isodose curve mappings measured while undergoing rotation for quality assurance testing of a 137Cs irradiator.

Authors:  Samuel L Brady; Terry T Yoshizumi; Colin Anderson-Evans; Giao Nguyen
Journal:  Health Phys       Date:  2012-02       Impact factor: 1.316

5.  UNLAMINATED GAFCHROMIC EBT3 FILM FOR ULTRAVIOLET RADIATION MONITORING.

Authors:  David Welch; Gerhard Randers-Pehrson; Henry M Spotnitz; David J Brenner
Journal:  Radiat Prot Dosimetry       Date:  2017-11-01       Impact factor: 0.972

6.  A feasibility study using radiochromic films for fast neutron 2D passive dosimetry.

Authors:  Samuel L Brady; Rathnayaka Gunasingha; Terry T Yoshizumi; Calvin R Howell; Alexander S Crowell; Brent Fallin; Anton P Tonchev; Mark W Dewhirst
Journal:  Phys Med Biol       Date:  2010-08-06       Impact factor: 3.609

7.  Linearization of dose-response curve of the radiochromic film dosimetry system.

Authors:  Slobodan Devic; Nada Tomic; Saad Aldelaijan; Francois Deblois; Jan Seuntjens; Maria F Chan; Dave Lewis
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.506

8.  An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan.

Authors:  David Lewis; Andre Micke; Xiang Yu; Maria F Chan
Journal:  Med Phys       Date:  2012-10       Impact factor: 4.506

9.  Incorporation of gantry angle correction for 3D dose prediction in intensity-modulated radiation therapy.

Authors:  Iori Sumida; Hajime Yamaguchi; Hisao Kizaki; Keiko Aboshi; Mari Tsujii; Yuji Yamada; Masashi Yagi; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2015-03-04       Impact factor: 2.724

10.  Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films.

Authors:  Ning Wen; Siming Lu; Jinkoo Kim; Yujiao Qin; Yimei Huang; Bo Zhao; Chang Liu; Indrin J Chetty
Journal:  Radiat Oncol       Date:  2016-10-04       Impact factor: 3.481

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.