Literature DB >> 15237873

Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study.

Roland Glauser1, Irena Sailer, Arnold Wohlwend, Stephan Studer, Monica Schibli, Peter Schärer.   

Abstract

PURPOSE: This prospective clinical study evaluated an experimental implant abutment made of densely sintered zirconia with respect to peri-implant hard and soft tissue reaction as well as fracture resistance over time.
MATERIALS AND METHODS: Twenty-seven consecutively treated patients with 54 single-tooth implants were included. Zirconia abutment ingots were individually shaped and set on the implants with gold screws. All-ceramic (Empress I) crowns were cemented using a composite cement. At the 1- and 4-year examinations, reconstructions were evaluated for technical problems (fracture of abutment or crown, loosening of abutment screw). Modified Plaque and simplified Gingival Indices were recorded at implants and neighboring teeth, and peri-implant bone levels were radiographically determined.
RESULTS: All but 1 of the 27 patients with 53 restorations could be evaluated at 1 year, and 36 restorations in 18 patients were evaluated 4 years after abutment and crown insertion. The median observation period for the reconstructions was 49.2 months. No abutment fractures occurred. Abutment screw loosening was reported for 2 restorations at 8 months and 27 months, respectively. Mean Plaque Index was 0.4 (SD 0.6) at abutments and 0.5 (SD 0.6) at teeth; mean Gingival Index was 0.7 (SD 0.5) at abutments and 0.9 (SD 0.5) at teeth. Mean marginal bone loss measured 1.2 mm (SD 0.5) after 4 years of functional loading.
CONCLUSION: Zirconia abutments offered sufficient stability to support implant-supported single-tooth reconstructions in anterior and premolar regions. The soft and hard tissue reaction toward zirconia was favorable.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15237873

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  39 in total

Review 1.  Mechanical resistance of zirconium implant abutments: a review of the literature.

Authors:  R Velázquez-Cayón; C Vaquero-Aguilar; D Torres-Lagares; M Jiménez-Melendo; J-L Gutiérrez-Pérez
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

2.  Implant adaptation of stock abutments versus CAD/CAM abutments: a radiographic and Scanning Electron Microscopy study.

Authors:  Davide Apicella; Mario Veltri; Nicoletta Chieffi; Antonella Polimeni; Agostino Giovannetti; Marco Ferrari
Journal:  Ann Stomatol (Roma)       Date:  2011-02-13

3.  Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result.

Authors:  Florian Beuer; Caroline Sachs; Julian Groesser; Jan-Frederik Gueth; Michael Stimmelmayr
Journal:  Clin Oral Investig       Date:  2015-09-24       Impact factor: 3.573

Review 4.  Adhesion/cementation to zirconia and other non-silicate ceramics: where are we now?

Authors:  Jeffrey Y Thompson; Brian R Stoner; Jeffrey R Piascik; Robert Smith
Journal:  Dent Mater       Date:  2010-11-20       Impact factor: 5.304

5.  Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns.

Authors:  Frank P Nothdurft; Klaus E Doppler; Kurt J Erdelt; Andreas W Knauber; Peter R Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-19       Impact factor: 3.573

6.  Clinical performance of screw-retained and cemented implant-supported zirconia single crowns: 36-month results.

Authors:  Claudio Cacaci; Friederike Cantner; Thomas Mücke; Peter Randelzhofer; Jan Hajtó; Florian Beuer
Journal:  Clin Oral Investig       Date:  2016-10-29       Impact factor: 3.573

7.  Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry.

Authors:  Frank P Nothdurft; Konrad Neumann; Andreas W Knauber
Journal:  Clin Oral Investig       Date:  2013-09-20       Impact factor: 3.573

Review 8.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

9.  Influence of finish line in the distribution of stress trough an all ceramic implant-supported crown.: A 3D Finite Element Analysis.

Authors:  G Sannino; F Gloria; L Ottria; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2010-03-04

10.  Bone tissue response to experimental zirconia implants.

Authors:  Ilja Mihatovic; Vladimir Golubovic; Jürgen Becker; Frank Schwarz
Journal:  Clin Oral Investig       Date:  2016-08-09       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.