Radiographic verification of implant abutment seating.

S M Cameron1, A Joyce, J S Brousseau, M H Parker.   

Abstract

STATEMENT OF PROBLEM: It is possible to incorrectly seat an abutment on an external hex implant.
PURPOSE: This study investigated the theoretical and practical limits of radiographic verification of the complete seating of implant abutments on external hex implants.
MATERIAL AND METHODS: A positioning device that could accurately place the film and/or tube head in any vertical relation desired relative to the implant and abutment was fabricated. For all records, a standard abutment was secured to the implant in both a fully seated position (closed) and with the abutment turned approximately 30 degrees and seated atop the implant external hex (open). Digital radiographs were made with the tube head fixed perpendicular to the implant and the film angled at 0, 5, 10, 15, 20, 25, 30, 35, 40, and 45 degrees. The film was then positioned parallel to the implant and the tube head was angled at 0, 5, 10, 15, 20, 25, 30, 35, 40, and 45 degrees. An image of each position was shown to 36 dentists and they were asked if the image was diagnostic for determining the status of the implant/abutment interface.
RESULTS: The data were analyzed with a computer statistics program. The group with the tube head changed was analyzed with the Cochran's Q test and revealed a statistically significant (p < 0.0001) change in the diagnostic value of radiographs beginning at 20 degrees. The group with the film angle changed was analyzed with a Pearson chi-square and showed no statistical difference (p = 0.394) for the diagnostic value of any of the film angles.
CONCLUSION: Maintaining the tube head to less than 20 degrees from perpendicular to the long axis of the implant resulted in a diagnostic radiograph, regardless of the angle of the film.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9553883     DOI: 10.1016/s0022-3913(98)70241-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Implant adaptation of stock abutments versus CAD/CAM abutments: a radiographic and Scanning Electron Microscopy study.

Authors:  Davide Apicella; Mario Veltri; Nicoletta Chieffi; Antonella Polimeni; Agostino Giovannetti; Marco Ferrari
Journal:  Ann Stomatol (Roma)       Date:  2011-02-13

2.  Assessing fit at the implant-abutment junction with a radiographic device that does not require access to the implant body.

Authors:  Kevin C Lin; Chandur P K Wadhwani; Jing Cheng; Arun Sharma; Frederick Finzen
Journal:  J Prosthet Dent       Date:  2014-05-14       Impact factor: 3.426

Review 3.  Using acrylic customized X-ray positioning stents for long-term follow-up studies.

Authors:  Sherif Aly Sadek; Hisham Mohamed Abbas; Moayad Alfelali; Abdulaziz Almahdali
Journal:  Saudi Dent J       Date:  2019-10-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.