Corrosion in Haas expanders with and without use of an antimicrobial agent: an in situ study.

Cristhiane Ristum Bagatin1, Izabel Yoko Ito, Marcela Cristina Damião Andrucioli, Paulo Nelson-Filho, José Tarcísio Lima Ferreira.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate in situ the occurrence of corrosion in the soldering point areas between the wire, silver brazing and band in Haas expanders.
MATERIAL AND METHODS: Thirty-four 7-12-year-old patients who needed maxillary expansion with a Haas expander were randomly assigned to two groups of 17 individuals each, according to the oral hygiene protocol adopted during the orthodontic treatment: Group I (control), toothbrushing with a fluoride dentifrice and Group II (experimental), toothbrushing with the same dentifrice plus 0.12% chlorhexidine gluconate (Periogard®) mouthrinses twice a week. The appliances were removed after approximately 4 months. Fragments of the appliances containing a metallic band with a soldered wire were sectioned at random for examination by stereomicroscopy, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS). Data were analyzed statistically by Fisher's test at 5% significance level.
RESULTS: The analysis by optical microscopy revealed areas with color change suggestive of corrosion in the soldering point areas joining the band and the wire in all specimens of both groups, with no statistically significant difference between the groups (p=1). The peaks of chemical elements (Ni, Fe, Cr, O, C and P) revealed by EDS were also similar in both groups.
CONCLUSION: Color changes and peaks of chemical elements suggestive of corrosion were observed in the soldering point areas between the wire, silver brazing and band in both control and experimental groups, which indicate that the 0.12% chlorhexidine gluconate mouthrinses did not influence the occurrence of corrosion in situ.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22231004      PMCID: PMC3973471          DOI: 10.1590/s1678-77572011000600020

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

The oral environment is particularly favorable to metal biodegradation due to its chemical, thermal, microbiological and enzymatic conditions[19]. When in contact with saliva and acid/basic foods at different temperatures, the metal components of orthodontic appliances may undergo corrosion[2]. In addition, the orthodontic treatment, especially with fixed appliances, causes specific alterations in the oral cavity, including decrease of pH, increase of dental biofilm accumulation[26] and elevation of the salivary microbial levels[6,27], which are favorable conditions to the occurrence of corrosion. Corrosion of orthodontic appliances may have serious clinical implications that range from loss of dimension of the appliance's components, which results in application of lower force to the teeth, up to possible failure of the appliance due to tension corrosion[2]. In the corrosive process, the released metallic ions may get in contact with cells and tissues in the contiguous environment or pervade throughout the body. Absorption of toxic products released during corrosion of metallic orthodontic components by body tissues is undesirable[11,14,28]. In dentistry, corrosion may manifest as biological, functional and esthetic effects, the biological being the most significant[10,14,18]. The released metallic ions may cause damage or sensitization due to the toxicity[17,21]. Corrosion in orthodontic appliances has been extensively investigated by analysis of ion release both in vitro [2,4,17] and in vivo [1,13,20]. Considering that fixed orthodontic appliances may act as retention niches for microorganisms[23,25] and are susceptible to corrosion, the development of in situ studies evaluating corrosion from a clinical standpoint is of paramount importance. This study evaluated in situ the corrosion of the metallic components of Haas expanders by stereomicroscopy, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS).

MATERIAL AND METHODS

Thirty-four patients of both sexes (14 male and 20 female) aged 6 to 12 years (mean age = 9 years and 7 months) from the Orthodontic Clinic of the Ribeirão Preto Dental School, University of São Paulo, Brazil, who needed maxillary expansion with a Haas expander for correction of posterior crossbite were enrolled in this study. The children were randomly assigned to two groups of 17 individuals each (Groups I and II). Patients who were using antimicrobial mouthwashes, presented any systemic disease and/or had used antibiotics within the previous 3 months were excluded from the trial. This research project was approved by the local Ethics in Research Committee (process number 2006.1.391.58.9) and written informed consent was obtained from the parents or guardians. For construction of the Haas expanders, the permanent first molars were banded and the metallic bands were silver welded (Dental Morelli, Sorocaba, SP, Brazil) to 0.9 mm stainless steel orthodontic wires (Dentaurum, Ispringen, Germany). The active component was an 11 mm expanding screw (Dental Morelli, Sorocaba, SP, Brazil). The bands were cemented with zinc phosphate cement (LS cement; Vigodent S/A Indústria e Comércio, Rio de Janeiro, RJ, Brazil) and the orthodontic wires were fixed to the primary canines or molars with light-cured composite resin (TPH; 3M/ESPE, St. Paul, MN, USA). After correction of the posterior crossbite, which lasted 20 days on average, the orthodontic appliance was maintained for additional 3 months in the mouth as a retention period. During the time of use of the appliances, the patients were submitted to different oral hygiene protocols. The patients of Group I were instructed to brush their teeth with a fluoride dentifrice 3 times a day and not to use any antimicrobial mouthrinse solution. For patients of Group II, in addition to toothbrushing with a fluoride dentifrice, 1-minute mouthrinses with 10 mL of a 0.12% chlorhexidine gluconate solution (Periogard®; Colgate-Palmolive Company, New York, NY, USA) were prescribed twice a week (Tuesdays and Fridays). On Tuesdays, mouthrinsing was performed at the Dental School under the researcher's supervision, while on Fridays mouthrinsing was performed at the child's home under parental supervision. After removal from the mouth, the fixed appliances of both groups were cut with a sterile pair of pliers (Orthopli 021; Dentaurum, Pforzheim, Germany) on either the right or the left side, according to a table of random numbers, in order to obtain a fragment containing a sample of the wire/silver brazing/band region. The fragments were placed in a 300-mm desiccator (Vidrolabor, Paulínia, SP, Brazil) containing silica gel as an indicator of humidity for further analysis of the corrosive process. After desiccation, the specimens were examined with an optical stereomicroscope (Leica L2; Wetzlar, Germany) coupled to a digital camera (Sony Cyber Shot 3.3 mega pixels DSC-575, Tokyo, Japan) at x40 magnification to obtain images of the soldering point areas (silver brazing/band, silver brazing/wire and wire/silver brazing/band), as suggested by Wichelhaus, et al.[30] (2004). The images were analyzed with respect to the presence of areas with color change due to oxidation, suggestive of corrosion. This type of qualitative analysis has been described in several studies[9,21,30] and allowed delimiting the areas to be examined by SEM and EDS. Data referring to the presence (+) or absence (-) of color change suggestive of in situ corrosion in both groups were compared by Fisher's test using the SAS (Statistical Analysis System, Institute Inc., Cary, NC, USA) statistical software package at 5% significance level. The specimens were then processed for analysis by SEM and EDS. The analysis was undertaken with a scanning electron microscope (EVO 50 EP; Carl Zeiss SMT AG, Germany) operating at 20 kV coupled to an energy dispersive x-ray spectrometer (IXRF Systems Inc., Houston, TX, USA), which allows analyzing the predetermined area at x60 to 194 magnification with four-quadrant electron-backscatter detectors (QBSD) using a pre-determined depth of penetration of the electron beam. This analysis was performed to identify the peaks of the following chemical elements: nickel (Ni), iron (Fe), chromium (Cr), oxygen (O), carbon (C) and phosphorus (P) in the region delimited in the fragments of the appliances of Groups I and II. Graphs of the peaks of these chemical elements were obtained using the EDX/2004 software.

RESULTS

The analysis of the images obtained under optical stereomicroscopy revealed areas of color change suggestive of corrosion in the soldering point areas (wire/silver brazing/band region) in all specimens of both groups (Figure 1A and B), with no statistically significant difference (p=1).
Figure 1

A: Stereomicroscopic analysis of a representative Group I specimen showing color change in the band/silver brazing/wire joint. ×20 magnification. B: Close-up view of A showing color change suggestive of corrosion at the band/ silver brazing/wire joint. ×40 magnification. C: Scanning electron microscopy (SEM) micrograph showing the band/silver brazing/wire joint to be analyzed by energy dispersive x-ray spectroscopy (EDS). ×60 magnification. D: Areas of Ag solder (a), material-to-material interface (b) and orthodontic wire (c) analyzed by EDS with four-quadrant electron backscatter detectors QBSD detectors

A: Stereomicroscopic analysis of a representative Group I specimen showing color change in the band/silver brazing/wire joint. ×20 magnification. B: Close-up view of A showing color change suggestive of corrosion at the band/ silver brazing/wire joint. ×40 magnification. C: Scanning electron microscopy (SEM) micrograph showing the band/silver brazing/wire joint to be analyzed by energy dispersive x-ray spectroscopy (EDS). ×60 magnification. D: Areas of Ag solder (a), material-to-material interface (b) and orthodontic wire (c) analyzed by EDS with four-quadrant electron backscatter detectors QBSD detectors The regions suggestive of corrosion were submitted to SEM examination (Figure 1C) with EDS analysis (Figure 1D). Graphs representative of the qualitative readings of the specimens of Groups I and II are presented in Figures 2 and 3.
Figure 2

Quantitative energy dispersive x-ray spectroscopy (EDS) reading representative of areas of color change suggestive of corrosion in the soldered region in contact with the band and the wire in a Group I specimen (control)

Figure 3

Quantitative energy dispersive x-ray spectroscopy (EDS) reading representative of areas of color change suggestive of corrosion in the soldered region in contact with the band and the wire in a Group II specimen (Periogard® mouthrinse)

Quantitative energy dispersive x-ray spectroscopy (EDS) reading representative of areas of color change suggestive of corrosion in the soldered region in contact with the band and the wire in a Group I specimen (control) Quantitative energy dispersive x-ray spectroscopy (EDS) reading representative of areas of color change suggestive of corrosion in the soldered region in contact with the band and the wire in a Group II specimen (Periogard® mouthrinse) In both groups, the soldered areas in contact with the band and the wire presented Fe, Cr, O, C and P peaks. Expressive Ni peaks were not observed in either of the groups. Figure 4 illustrates the reading obtained in a non-assayed region of an orthodontic wire of a Haas expander. No area of corrosion was visible under optical stereomicroscopy, demonstrating how the peaks of chemical elements behave in this situation.
Figure 4

Quantitative reading of the composition of the stainless steel wire showing absence of corrosion

Quantitative reading of the composition of the stainless steel wire showing absence of corrosion

DISCUSSION

Several studies have currently evaluate the resistance to corrosion of orthodontic wires and brackets in an attempt to find materials with greater compatibility with the oral environment[4,5,21,24,28]. However, most studies are in vitro experiments that are performed with artificial saliva and methodologies that simulate the oral conditions, reaching results that cannot be extrapolated to the clinical situation. The present investigation was designed as a randomized clinical trial because it is the "golden standard" of studies that evaluate the clinical efficacy of materials and treatment techniques[12]. Soldering is still the prevailing joining technique in the dental laboratory, although problems arise from the susceptibility to corrosion and the low strength of soldered joints. In the flame soldering technique, the wire elements are heated directly, so that the temperature of the wire mostly rises to levels exceeding the fusing temperature of the solder. Under these conditions, intergranular corrosion occurs due to the change in the composition of grain contours deriving from phase precipitations, concentration of impurities or elementary Cr depletion close to the areas of grain contours[2]. The results of the present study showed the occurrence of failure in the flame-soldered joints between the stainless steel wires occurred during the construction of the Haas expanders. These findings are in agreement with those of Heidemann, et al.[16] (2002) who evaluated in vitro different soldering techniques produced by various dental technicians and observed incomplete filling of the soldering gap, porosities resulting from the production process, local structural changes due to overheating and deficient alloying at the solder margin. The EDS analysis qualifies chemically the composition of a certain material, being a complementary method to evaluate the presence of corrosion[11,15,21,28]. Under ideal conditions, Fe and Cr peaks in the soldered joint should be high and similar. Graphs with high Fe peaks and medium Cr peaks and presence of O suggest the occurrence of corrosion due to formation of Fe2O3 or hydrated ferric oxide (Fe2O3 x H2O), indicating rust[5,22]. The presence of P with high Fe peaks and medium Cr peaks suggests the occurrence of a process corrosive by formation of iron phosphate (FePO4)[29]. In the present study, peaks of these elements were observed in the soldered joints in all specimens of both groups. The deterioration of orthodontic appliances has been a matter of concern in orthodontic research due to the potential adverse biological reactions associated mainly to Ni release[3,7]. In the present in situ study, the EDS analysis did not reveal Ni peaks in the soldered joints of any of the Haas expanders worn for approximately 4 months. Although no increase in the Ni levels were observed, which would indicate a corrosive process, the presence of corrosion was detected on examination of the images under optical microscopy. Intergranular corrosion was most likely the cause[5]. This situation is further aggravated if one considers two other conditions that may contribute to potentialize corrosion: the mouth is an aggressive oral environment to the various types of sensitized alloys and crevice corrosion is intensified where gaps and/or cracks develop[16]. In addition to intergranular and crevice corrosion, the stainless steel becomes susceptible to the corrosive process, since the alloy has its structure altered and the passivation film cannot be reestablished. This permits the occurrence of different types of corrosion: fatigue corrosion, which occurs frequently in orthodontic wires submitted to long intraoral periods under load[8]; microbiological corrosion, which causes color change in the presence of microorganisms due to action of sulfur or reduction of sulfates to hydrogen sulfide and formation of insoluble dark sulfites, in addition to pitting (corrosive attack that occurs in points or small areas) and deposits that may occur in the presence of microorganisms[5]; and galvanic corrosion, which is the deterioration of an alloy by transference of electrons due to difference of potential between two materials in the presence of a common electrolyte. The C peaks observed in the EDS analysis were greater in Group I, possibly due to the greater accumulation of bacterial biofilm. The P peaks were very expressive in all specimens, possibly originating from the saliva and/or the zinc phosphate cement used for cementation of the orthodontic bands. The presence of Ag peaks in the graphs of soldered joints distant from material-to-material interface only suggests the presence of the metal used as a soldering material. Although the methodology of the present study does not allow determining accurately which factors caused corrosion, alterations occurred in the wire/silver brazing/band joints, since a dark line suggestive of corrosion was observed on the alloy by optical microscopy and SEM, though without significant difference between the groups.

CONCLUSIONS

Under the conditions evaluated in this randomized clinical study, it may be concluded that there were color change and peaks of chemical elements suggestive of corrosion in all specimens of both groups in the soldering point areas between the wire, silver brazing and bands of the Haas expanders, with no difference between the groups. These results suggest that the use of chlorhexidine mouthrinses did not influence the occurrence of corrosion in situ.
  28 in total

1.  Intraoral aging of the inner headgear component: a potential biocompatibility concern?

Authors:  T Eliades; G Eliades; D C Watts
Journal:  Am J Orthod Dentofacial Orthop       Date:  2001-03       Impact factor: 2.650

2.  Surface characterization of retrieved NiTi orthodontic archwires.

Authors:  T Eliades; G Eliades; A E Athanasiou; T G Bradley
Journal:  Eur J Orthod       Date:  2000-06       Impact factor: 3.075

Review 3.  In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility.

Authors:  Theodore Eliades; Athanasios E Athanasiou
Journal:  Angle Orthod       Date:  2002-06       Impact factor: 2.079

4.  Orthodontic soldering techniques: aspects of quality assurance in the dental laboratory.

Authors:  Jutta Heidemann; Emil Witt; Martin Feeg; Rainer Werz; Klaus Pieger
Journal:  J Orofac Orthop       Date:  2002-07       Impact factor: 1.938

5.  Effect of chlorhexidine varnish application on mutans streptococci counts in orthodontic patients.

Authors:  Aniek Derks; Jo Frencken; Ewald Bronkhorst; Anne Marie Kuijpers-Jagtman; Christos Katsaros
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-03       Impact factor: 2.650

6.  In-vivo evaluation of the contamination of Super Slick elastomeric rings by Streptococcus mutans in orthodontic patients.

Authors:  Amanda Fahning Ferreira Magno; Carla Enoki; Izabel Yoko Ito; Mirian Aiko Nakane Matsumoto; Gisele Faria; Paulo Nelson-Filho
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-04       Impact factor: 2.650

7.  Metallurgical characterization, galvanic corrosion, and ionic release of orthodontic brackets coupled with Ni-Ti archwires.

Authors:  Myrsini S Darabara; Lefteris I Bourithis; Spiros Zinelis; George D Papadimitriou
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-04       Impact factor: 3.368

8.  Nickel and chromium levels in the saliva and serum of patients with fixed orthodontic appliances.

Authors:  G Ağaoğlu; T Arun; B Izgi; A Yarat; B Izgü
Journal:  Angle Orthod       Date:  2001-10       Impact factor: 2.079

9.  Analyses of rampant corrosion in stainless-steel retainers of orthodontic patients.

Authors:  R P Kusy; W W Ambrose; L A LaVanier; J G Newman; J Q Whitley
Journal:  J Biomed Mater Res       Date:  2002-10

10.  In vitro evaluation of corrosion and cytotoxicity of orthodontic brackets.

Authors:  M T Costa; M A Lenza; C S Gosch; I Costa; F Ribeiro-Dias
Journal:  J Dent Res       Date:  2007-05       Impact factor: 6.116

View more
  3 in total

1.  Antibacterial effect of an herbal toothpaste containing Bamboo salt: a randomized double-blinded controlled clinical trial.

Authors:  Mina Biria; Yasaman Rezvani; Romina Roodgarian; Abbas Rabbani; Parastoo Iranparvar
Journal:  BMC Oral Health       Date:  2022-05-19       Impact factor: 3.747

2.  Mapping chemical elements on the surface of orthodontic appliance by SEM-EDX.

Authors:  Marcin Mikulewicz; Paulina Wołowiec; Izabela Michalak; Katarzyna Chojnacka; Wojciech Czopor; Adam Berniczei-Royko; Andras Vegh; Thomas Gedrange
Journal:  Med Sci Monit       Date:  2014-05-25

3.  Antibacterial effect of water-soluble chitosan on representative dental pathogens Streptococcus mutans and Lactobacilli brevis.

Authors:  Chih-Yu Chen; Ying-Chien Chung
Journal:  J Appl Oral Sci       Date:  2012 Nov-Dec       Impact factor: 2.698

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.