Corrosion of stainless steel, nickel-titanium, coated nickel-titanium, and titanium orthodontic wires.

H Kim1, J W Johnson.   

Abstract

Orthodontic wires containing nickel have been implicated in allergic reactions. The potential for orthodontic wires to cause allergic reactions is related to the pattern and mode of corrosion with subsequent release of metal ions, such as nickel, into the oral cavity. The purpose of this study was to determine if there is a significant difference in the corrosive potential of stainless steel, nickel titanium, nitride-coated nickel titanium, epoxy-coated nickel titanium, and titanium orthodontic wires. At least two specimens of each wire were subjected to potentiostatic anodic dissolution in 0.9% NaCl solution with neutral pH at room temperature. Using a Wenking MP 95 potentiostat and an electrochemical corrosion cell, the breakdown potential of each wire was determined. Photographs were taken of the wire speci mens using a scanning electron microscope, and surface changes were qualitatively evaluated. The breakdown potentials of stainless steel, two nickel titanium wires, nitride-coated nickel titanium, epoxy-coated nickel titanium, and titanium were 400 mV, 300 mV, 750 mV, 300 mV, 1800 mV, and >2000 mV, respectively. SEM photographs revealed that some nickel titanium and stainless steel wires were susceptible to pitting and localized corrosion. The results indicate that corrosion occurred readily in stainless steel. Variability in breakdown potential of nickel titanium alloy wires differed across vendors' wires. The nitride coating did not affect the corrosion of the alloy, but epoxy coating decreased corrosion. Titanium wires and epoxy-coated nickel titanium wires exhibited the least corrosive potential. For patients allergic to nickel, the use of titanium or epoxy-coated wires during orthodontic treatment is recommended.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10022183     DOI: 10.1043/0003-3219(1999)069<0039:COSSNT>2.3.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  23 in total

1.  Effect of fluoride agents on surface characteristics of NiTi wires. An ex vivo investigation.

Authors:  Prasad Chitra; G S Prashantha; Arun Rao
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-05

2.  Friction coefficients and wear rates of different orthodontic archwires in artificial saliva.

Authors:  M V Alfonso; E Espinar; J M Llamas; E Rupérez; J M Manero; J M Barrera; E Solano; F J Gil
Journal:  J Mater Sci Mater Med       Date:  2013-02-26       Impact factor: 3.896

3.  Electrochemical behavior of nitinol alloy in Ringer's solution.

Authors:  E X Sun; S Fine; W B Nowak
Journal:  J Mater Sci Mater Med       Date:  2002-10       Impact factor: 3.896

4.  In vitro evaluation of surface topographic changes and nickel release of lingual orthodontic archwires.

Authors:  Carlos Suárez; Teresa Vilar; Javier Gil; Pablo Sevilla
Journal:  J Mater Sci Mater Med       Date:  2009-10-14       Impact factor: 3.896

5.  Biomonitorization of metal ions in the serum of Iranian patients treated with fixed orthodontic appliances in comparison with controls in eastern Iran.

Authors:  Mahdjoube Goldani Moghadam; Reyhane Hoshyar; Marcin Mikulewicz; Katarzyna Chojnacka; Geir Bjørklund; Joeri J Pen; Nammam Ali Azadi; Maghdad Pirsaheb; Meysam Dashtaki; Borhan Mansouri
Journal:  Environ Sci Pollut Res Int       Date:  2019-09-14       Impact factor: 4.223

6.  Nickel and chromium levels in the saliva of a Saudi sample treated with fixed orthodontic appliances.

Authors:  Nabeel F Talic; Hasan H Alnahwi; Ali S Al-Faraj
Journal:  Saudi Dent J       Date:  2013-10-19

7.  Corrosion resistance of surface modified nickel titanium archwires.

Authors:  Manu Krishnan; Saraswathy Seema; A Vinod Kumar; N Parvatha Varthini; Kalathil Sukumaran; Vasant R Pawar; Vimal Arora
Journal:  Angle Orthod       Date:  2013-09-04       Impact factor: 2.079

8.  Load-deflection and surface properties of coated and conventional superelastic orthodontic archwires in conventional and metal-insert ceramic brackets.

Authors:  Shiva Alavi; Navid Hosseini
Journal:  Dent Res J (Isfahan)       Date:  2012-03

9.  Comparison of Galvanic Currents Generated Between Different Combinations of Orthodontic Brackets and Archwires Using Potentiostat: An In Vitro Study.

Authors:  Rabindra S Nayak; Bareera Shafiuddin; Azam Pasha; K Vinay; Anjali Narayan; Smitha V Shetty
Journal:  J Int Oral Health       Date:  2015-07

10.  Cytotoxic effects of the nickel release from the stainless steel brackets: An in vitro study.

Authors:  Ajith Rajasekharan Pillai; Anil Gangadharan; Jithin Gangadharan; Nallasamy Vijaya Kumar
Journal:  J Pharm Bioallied Sci       Date:  2013-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.