Literature DB >> 22223160

Repeated measurements of the anterior segment during accommodation using long scan depth optical coherence tomography.

Yimin Yuan1, Feng Chen, Meixiao Shen, Fan Lu, Jianhua Wang.   

Abstract

OBJECTIVES: The aim was to determine the repeatability of ultralong scan depth spectral-domain optical coherence tomography (SD-OCT) measurements of the ocular anterior segment during accommodation.
METHODS: The center wavelength of the SD-OCT light source was 840 nm with a bandwidth of 50 nm. The ocular axial resolution of the system was approximately 6.0 μm, and the scan depth was 7.2 mm in air. Twenty eyes of 20 healthy subjects were imaged with a custom-built, ultralong scan depth SD-OCT during 2 visits. The anterior segment images were acquired during nonaccommodative and maximal accommodative states. After image processing and correction, the true values of the morphometric dimensions of the anterior eye were obtained. The variables of the two states from two visits were compared.
RESULTS: For the corrected anterior segment images, the variables did not significantly differ from one visit to the next. The values of anterior chamber depth, pupil diameter, and the radius of the lens anterior surface curvature during accommodation were significantly smaller than those during the nonaccommodative state. The lens thickness significantly increased with accommodation. There was no significant difference in the posterior surface curvature of the lens between the two states.
CONCLUSIONS: Ultralong scan depth SD-OCT holds promise for quantifying dimensional changes in the eye during accommodation. The instrument demonstrated good repeatability of ocular anterior segment dimensional measurements during accommodation.

Entities:  

Mesh:

Year:  2012        PMID: 22223160      PMCID: PMC3362999          DOI: 10.1097/ICL.0b013e318243e795

Source DB:  PubMed          Journal:  Eye Contact Lens        ISSN: 1542-2321            Impact factor:   2.018


  32 in total

1.  Static and dynamic analysis of the anterior segment with optical coherence tomography.

Authors:  Georges Baikoff; Eric Lutun; Caroline Ferraz; Jay Wei
Journal:  J Cataract Refract Surg       Date:  2004-09       Impact factor: 3.351

2.  Influence of accommodation on the anterior and posterior cornea.

Authors:  Scott A Read; Tobias Buehren; Michael J Collins
Journal:  J Cataract Refract Surg       Date:  2007-11       Impact factor: 3.351

3.  Unified model for accommodative mechanism.

Authors:  D J Coleman
Journal:  Am J Ophthalmol       Date:  1970-06       Impact factor: 5.258

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Ultrasound measures of vitreous chamber depth during ocular accommodation.

Authors:  R Beauchamp; B Mitchell
Journal:  Am J Optom Physiol Opt       Date:  1985-08

6.  Lens thickness with age and accommodation by optical coherence tomography.

Authors:  Kathryn Richdale; Mark A Bullimore; Karla Zadnik
Journal:  Ophthalmic Physiol Opt       Date:  2008-09       Impact factor: 3.117

7.  Anterior chamber optical coherence tomography study of human natural accommodation in a 19-year-old albino.

Authors:  Georges Baikoff; Eric Lutun; Jay Wei; Caroline Ferraz
Journal:  J Cataract Refract Surg       Date:  2004-03       Impact factor: 3.351

8.  Entire contact lens imaged in vivo and in vitro with spectral domain optical coherence tomography.

Authors:  Meixiao Shen; Michael R Wang; Jianhua Wang; Yimin Yuan; Feng Chen
Journal:  Eye Contact Lens       Date:  2010-03       Impact factor: 2.018

9.  High speed full range complex spectral domain optical coherence tomography.

Authors:  Erich Götzinger; Michael Pircher; Rainer Leitgeb; Christoph Hitzenberger
Journal:  Opt Express       Date:  2005-01-24       Impact factor: 3.894

10.  A normative study of the accommodative lag in elementary school children.

Authors:  M W Rouse; R F Hutter; R Shiftlett
Journal:  Am J Optom Physiol Opt       Date:  1984-11
View more
  14 in total

1.  Association between axial length and in vivo human crystalline lens biometry during accommodation: a swept-source optical coherence tomography study.

Authors:  Takuhei Shoji; Naoko Kato; Sho Ishikawa; Hisashi Ibuki; Norihiro Yamada; Itaru Kimura; Kei Shinoda
Journal:  Jpn J Ophthalmol       Date:  2019-11-23       Impact factor: 2.447

2.  Accommodative changes produced in response to overnight orthokeratology.

Authors:  Gema Felipe-Marquez; María Nombela-Palomo; Isabel Cacho; Amelia Nieto-Bona
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-12-09       Impact factor: 3.117

3.  Age-related changes in the anterior segment biometry during accommodation.

Authors:  Yilei Shao; Aizhu Tao; Hong Jiang; Xinjie Mao; Jianguang Zhong; Meixiao Shen; Fan Lu; Zhe Xu; Carol L Karp; Jianhua Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-06       Impact factor: 4.799

4.  Axial biometry of the entire eye using ultra-long scan depth optical coherence tomography.

Authors:  Jianguang Zhong; Yilei Shao; Aizhu Tao; Hong Jiang; Che Liu; Huicheng Zhang; Jianhua Wang
Journal:  Am J Ophthalmol       Date:  2013-10-07       Impact factor: 5.258

5.  Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT.

Authors:  Noelia Martínez-Albert; Jose J Esteve-Taboada; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-02       Impact factor: 3.117

6.  Dynamic imaging of accommodation by swept-source anterior segment optical coherence tomography.

Authors:  Alberto Neri; Marco Ruggeri; Alessandra Protti; Rosachiara Leaci; Stefano A Gandolfi; Claudio Macaluso
Journal:  J Cataract Refract Surg       Date:  2015-02-20       Impact factor: 3.351

7.  Entire thickness profiles of the epithelium and contact lens in vivo imaged with high-speed and high-resolution optical coherence tomography.

Authors:  Aizhu Tao; Yilei Shao; Hong Jiang; Yufeng Ye; Fan Lu; Meixiao Shen; Dexi Zhu; Jianhua Wang
Journal:  Eye Contact Lens       Date:  2013-09       Impact factor: 2.018

8.  Agreement between Orbscan II, VuMAX UBM and Artemis-2 very-high frequency ultrasound scanner for measurement of anterior chamber depth.

Authors:  Haya Matuoq Al Farhan
Journal:  BMC Ophthalmol       Date:  2014-02-25       Impact factor: 2.209

9.  Simultaneous real-time imaging of the ocular anterior segment including the ciliary muscle during accommodation.

Authors:  Yilei Shao; Aizhu Tao; Hong Jiang; Meixiao Shen; Jianguang Zhong; Fan Lu; Jianhua Wang
Journal:  Biomed Opt Express       Date:  2013-02-21       Impact factor: 3.732

10.  Reproducibility of the optical Biometer OA-1000 (Tomey).

Authors:  Susanne Christiane Goebels; Berthold Seitz; Achim Langenbucher
Journal:  Biomed Res Int       Date:  2014-04-10       Impact factor: 3.411

View more