Literature DB >> 15342045

Static and dynamic analysis of the anterior segment with optical coherence tomography.

Georges Baikoff1, Eric Lutun, Caroline Ferraz, Jay Wei.   

Abstract

PURPOSE: To study biometric modifications of the anterior segment with accommodation and age and determine possible applications in areas of anterior segment surgery, particularly implantation of refractive lenses.
SETTING: Clinique Monticelli, Marseille, France.
METHOD: The study comprised subjects between 7 years of age and 82 years of age in whom anterior chamber biometry was evaluated using 1,310 nm wavelength optical coherence tomography (OCT). The equipment has a fixation target that can be focused and defocused with negative lenses to stimulate natural accommodation. All measurements were performed by the same operator. The horizontal diameter of the AC, the anterior chamber depth (ACD), the horizontal pupil diameter, and the horizontal radius of curvature of the crystalline lens' anterior pole were measured in the unaccommodated state and after stimulating accommodation.
RESULTS: Fifty-six subjects (104 eyes) were included; the refractions ranged from +5.0 diopters (D) to -5.0 D. The static and dynamic measurements were compared with ametropia, age, and accommodation. At rest, the mean AC diameter was 12.334 mm, the mean ACD was 3.106 mm, and the mean pupil diameter was 4.258 mm. With 1.0 D of accommodation, the anterior pole moved forward by a mean of 30 microm, the radius of curvature decreased 0.3 mm, and the pupil diameter decreased 0.15 mm.
CONCLUSIONS: The AC OCT is a user-friendly instrument for evaluating the anterior segment and examining the AC (cornea, iris, crystalline lens, and iridocorneal angle). The 1,310 nm light wavelength is blocked by pigments, preventing examination behind the iris. However, the AC OCT is capable of good image quality and visualization of the anatomical relationships in the anterior segment, even behind an opaque cornea.

Entities:  

Mesh:

Year:  2004        PMID: 15342045     DOI: 10.1016/j.jcrs.2004.05.024

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  38 in total

1.  Lens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography.

Authors:  Nikoo Hamzeh; Sasan Moghimi; Golshan Latifi; Massood Mohammadi; Nassim Khatibi; Shan C Lin
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

2.  Optical coherence tomography of the Ex-PRESS miniature glaucoma implant.

Authors:  F D Verbraak; D M de Bruin; M Sulak; L A M S de Jong; M Aalders; D J Faber; T G van Leeuwen
Journal:  Lasers Med Sci       Date:  2005-04-28       Impact factor: 3.161

3.  Anterior optical coherence tomography: a non-contact technique for anterior chamber evaluation.

Authors:  Jens Dawczynski; Ekkehart Koenigsdoerffer; Regine Augsten; Juergen Strobel
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-08-01       Impact factor: 3.117

4.  High-frequency harmonic imaging of the eye.

Authors:  Ronald H Silverman; D Jackson Coleman; Jeffrey A Ketterling; Frederic L Lizzi
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

5.  Measurements of anterior segment parameters using three different non-contact optical devices in keratoconus patients.

Authors:  Ahmet Taylan Yazıcı; Gökhan Pekel; Ercüment Bozkurt; Yusuf Yıldırım; Evre Pekel; Ahmet Demirok; Omer Faruk Yılmaz
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

6.  Characteristics of higher-order aberrations and anterior segment tomography in patients with pathologic myopia.

Authors:  Kaori Kasahara; Naoyuki Maeda; Takashi Fujikado; Makoto Tomita; Muka Moriyama; Mutsumi Fuchihata; Kyoko Ohno-Matsui
Journal:  Int Ophthalmol       Date:  2016-11-28       Impact factor: 2.031

7.  Accommodative changes in human eye observed by Kitasato anterior segment optical coherence tomography.

Authors:  Nobuyuki Satoh; Kimiya Shimizu; Atsushi Goto; Akihito Igarashi; Kazutaka Kamiya; Kohji Ohbayashi; Hiroyuki Furukawa
Journal:  Jpn J Ophthalmol       Date:  2012-11-21       Impact factor: 2.447

8.  Full anterior segment biometry with extended imaging range spectral domain optical coherence tomography at 1340 nm.

Authors:  Peng Li; Murray Johnstone; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2014-04       Impact factor: 3.170

Review 9.  Ultra high-resolution anterior segment optical coherence tomography in the diagnosis and management of ocular surface squamous neoplasia.

Authors:  Benjamin J Thomas; Anat Galor; Afshan A Nanji; Fouad El Sayyad; Jianhua Wang; Sander R Dubovy; Madhura G Joag; Carol L Karp
Journal:  Ocul Surf       Date:  2013-11-09       Impact factor: 5.033

10.  Lens thickness with age and accommodation by optical coherence tomography.

Authors:  Kathryn Richdale; Mark A Bullimore; Karla Zadnik
Journal:  Ophthalmic Physiol Opt       Date:  2008-09       Impact factor: 3.117