Artifact reduction in truncated CT using Sinogram completion.

R Chityala1, K R Hoffmann, S Rudin, D R Bednarek.   

Abstract

Truncation of projection data in CT produces significant artifacts in the reconstruction process due to non-locality of the Radon transform. In this paper, we present a method for reducing these truncation artifacts by estimating features that lie outside the region of interest (ROI) and using these features to complete the truncated sinogram.Projection images of an object are obtained. A sinogram is obtained by stacking profile data from all projection angles. A simulated truncated sinogram is generated by setting pixel values outside an ROI to zero. The truncated sinogram is then transformed into a (radius, phase) image, with pixel values in what we term as the Polar representation (PR) image corresponding to the minimum value along sine curves given by x = r*cos(projection angle + phase). The PR image contains data for radii greater than the ROI radius. Pixel values outside the ROI in the completed sinogram are determined as follows. For each pixel in the PR image, a sine curve is generated in the completed sinogram image outside the ROI, having the same pixel value as that of the PR image for that radius and phase. Successive sine curves are laid and the values of each are summed. The intensity outside is then equalized to the intensity inside the ROI. The completed sinogram is then reconstructed, to obtain completed reconstruction.The percentage error in the difference image between the full FOV reconstruction and the corresponding completed reconstruction and the extrapolated-average reconstruction are 1.1% and 3.3% respectively. This indicates that the completed reconstruction is closer to full FOV reconstruction. Thus, the sinogram completion can be used to improve reconstructions from truncated data.

Year:  2005        PMID: 21874099      PMCID: PMC3161449          DOI: 10.1117/12.595450

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  3 in total

1.  Efficient correction for CT image artifacts caused by objects extending outside the scan field of view.

Authors:  B Ohnesorge; T Flohr; K Schwarz; J P Heiken; K T Bae
Journal:  Med Phys       Date:  2000-01       Impact factor: 4.071

2.  A novel reconstruction algorithm to extend the CT scan field-of-view.

Authors:  J Hsieh; E Chao; J Thibault; B Grekowicz; A Horst; S McOlash; T J Myers
Journal:  Med Phys       Date:  2004-09       Impact factor: 4.071

3.  Region of interest (ROI) computed tomography (CT): Comparison with full field of view (FFOV) and truncated CT for a human head phantom.

Authors:  R Chityala; K R Hoffmann; S Rudin; D R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005
  3 in total
  8 in total

1.  Strategy of computed tomography sinogram inpainting based on sinusoid-like curve decomposition and eigenvector-guided interpolation.

Authors:  Yinsheng Li; Yang Chen; Yining Hu; Ahmed Oukili; Limin Luo; Wufan Chen; Christine Toumoulin
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2012-01-01       Impact factor: 2.129

2.  Statistical projection completion in X-ray CT using consistency conditions.

Authors:  Jingyan Xu; Katsuyuki Taguchi; Benjamin M W Tsui
Journal:  IEEE Trans Med Imaging       Date:  2010-05-03       Impact factor: 10.048

3.  Volume-of-change cone-beam CT for image-guided surgery.

Authors:  Junghoon Lee; J Webster Stayman; Yoshito Otake; Sebastian Schafer; Wojciech Zbijewski; A Jay Khanna; Jerry L Prince; Jeffrey H Siewerdsen
Journal:  Phys Med Biol       Date:  2012-07-17       Impact factor: 3.609

4.  Hybrid cone-beam tomographic reconstruction: incorporation of prior anatomical models to compensate for missing data.

Authors:  Ofri Sadowsky; Junghoon Lee; E Grant Sutter; Simon J Wall; Jerry L Prince; Russell H Taylor
Journal:  IEEE Trans Med Imaging       Date:  2010-07-26       Impact factor: 10.048

5.  Hepatic dual-contrast CT imaging: slow triple kVp switching CT with CNN-based sinogram completion and material decomposition.

Authors:  Wenchao Cao; Nadav Shapira; Andrew Maidment; Heiner Daerr; Peter B Noël
Journal:  J Med Imaging (Bellingham)       Date:  2022-01-31

6.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

7.  Scout-view assisted interior micro-CT.

Authors:  Kriti Sen Sharma; Christian Holzner; Dragoş M Vasilescu; Xin Jin; Shree Narayanan; Masoud Agah; Eric A Hoffman; Hengyong Yu; Ge Wang
Journal:  Phys Med Biol       Date:  2013-06-04       Impact factor: 3.609

8.  Improved dynamic imaging of multiphase flow by constrained tomographic reconstruction.

Authors:  Henning Osholm Sørensen; Stefan Bruns; Anders Bjorholm Dahl; Peter Winkel Rasmussen; Anders Nymark Christensen
Journal:  Sci Rep       Date:  2021-06-14       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.