Literature DB >> 7464713

View sampling requirements in fan beam computed tomography.

P M Joseph, R A Schulz.   

Abstract

It is known that good CT reconstructions require that many views of the scanned object be obtained, where each view consists of many rays which traverse the patient. It is known that the required number of views depends on the diameter of the region reconstructed and the spatial resolution achieved. We present a new analysis of this question, valid for reconstruction from fan beam views, which shows that larger fan angles will require more views. Computer simulations, using a fan beam reconstruction algorithm, confirmed the predicted fan angle dependence and demonstrated that streak artifacts will result if too few views are used. The effect is also demonstrated experimentally by a phantom scan on a clinical CT scanner. Implications for clinical CT scanning are discussed.

Entities:  

Mesh:

Year:  1980        PMID: 7464713     DOI: 10.1118/1.594723

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Myocardial wall tagging with undersampled projection reconstruction.

Authors:  D C Peters; F H Epstein; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Strategy of computed tomography sinogram inpainting based on sinusoid-like curve decomposition and eigenvector-guided interpolation.

Authors:  Yinsheng Li; Yang Chen; Yining Hu; Ahmed Oukili; Limin Luo; Wufan Chen; Christine Toumoulin
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2012-01-01       Impact factor: 2.129

3.  C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential.

Authors:  Wei Chang; Caesar E Ordonez; Haoning Liang; Yusheng Li; Jingai Liu
Journal:  IEEE Trans Nucl Sci       Date:  2009-10-06       Impact factor: 1.679

4.  Subspace-based resolution-enhancing image reconstruction method for few-view differential phase-contrast tomography.

Authors:  Huifeng Guan; Charlotte Klara Hagen; Alessandro Olivo; Mark A Anastasio
Journal:  J Med Imaging (Bellingham)       Date:  2018-06-28

5.  A comprehensive study on the relationship between the image quality and imaging dose in low-dose cone beam CT.

Authors:  Hao Yan; Laura Cervino; Xun Jia; Steve B Jiang
Journal:  Phys Med Biol       Date:  2012-04-07       Impact factor: 3.609

6.  Bone-induced streak artifact suppression in sparse-view CT image reconstruction.

Authors:  Seung Oh Jin; Jae Gon Kim; Soo Yeol Lee; Oh-Kyong Kwon
Journal:  Biomed Eng Online       Date:  2012-08-02       Impact factor: 2.819

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.