View angle tilting echo planar imaging for distortion correction.

Sinyeob Ahn1, Xiaoping P Hu.   

Abstract

Geometric distortion caused by field inhomogeneity along the phase-encode direction is one of the most prominent artifacts due to a relatively low effective bandwidth along that direction in magnetic resonance echo planar imaging. This work describes a method for correcting in-plane image distortion along the phase-encode direction using a view angle tilting imaging technique in spin-echo echo planar imaging. Spin-echo echo planar imaging with view angle tilting uses the addition of gradient blips along the slice-select direction, concurrently applied with the phase-encode gradient blips, producing an additional phase. This phase effectively offsets an unwanted phase accumulation caused by field inhomogeneity, resulting in the removal of image distortion along the phase-encode direction. The proposed method is simple and straightforward both in implementation and application with no scan time penalty. Therefore, it is readily applicable on commercial scanners without having any customized postprocessing. The efficacy of the spin-echo echo planar imaging with view angle tilting technique in the correction of image distortion is demonstrated in phantom and in vivo brain imaging.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 22213567      PMCID: PMC3323714          DOI: 10.1002/mrm.23320

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  Improved MR imaging for patients with metallic implants.

Authors:  A M Viano; S A Gronemeyer; M Haliloglu; F A Hoffer
Journal:  Magn Reson Imaging       Date:  2000-04       Impact factor: 2.546

2.  Quantitative assessment of an MR technique for reducing metal artifact: application to spin-echo imaging in a phantom.

Authors:  M J Lee; D L Janzen; P L Munk; A MacKay; Q S Xiang; A McGowen
Journal:  Skeletal Radiol       Date:  2001-07       Impact factor: 2.199

3.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Correction of spatial distortion in EPI due to inhomogeneous static magnetic fields using the reversed gradient method.

Authors:  Paul S Morgan; Richard W Bowtell; Dominick J O McIntyre; Brian S Worthington
Journal:  J Magn Reson Imaging       Date:  2004-04       Impact factor: 4.813

5.  Quantitative MR susceptibility mapping using piece-wise constant regularized inversion of the magnetic field.

Authors:  Ludovic de Rochefort; Ryan Brown; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

6.  Correction for geometric distortion in echo planar images from B0 field variations.

Authors:  P Jezzard; R S Balaban
Journal:  Magn Reson Med       Date:  1995-07       Impact factor: 4.668

7.  Correction of off resonance-related distortion in echo-planar imaging using EPI-based field maps.

Authors:  P J Reber; E C Wong; R B Buxton; L R Frank
Journal:  Magn Reson Med       Date:  1998-02       Impact factor: 4.668

8.  Total inhomogeneity correction including chemical shifts and susceptibility by view angle tilting.

Authors:  Z H Cho; D J Kim; Y K Kim
Journal:  Med Phys       Date:  1988 Jan-Feb       Impact factor: 4.071

9.  An integrated program for amplitude-modulated RF pulse generation and re-mapping with shaped gradients.

Authors:  G B Matson
Journal:  Magn Reson Imaging       Date:  1994       Impact factor: 2.546

10.  SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Authors:  Wenmiao Lu; Kim Butts Pauly; Garry E Gold; John M Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

View more
  1 in total

1.  Induced magnetic moment in stainless steel components of orthodontic appliances in 1.5 T MRI scanners.

Authors:  Zhiyue J Wang; Nancy K Rollins; Hui Liang; Yong Jong Park
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.