Literature DB >> 10745138

Improved MR imaging for patients with metallic implants.

A M Viano1, S A Gronemeyer, M Haliloglu, F A Hoffer.   

Abstract

Pediatric oncology patients with large metallic prostheses were imaged with one of two MR imaging techniques: 1) the "tilted view-angle" technique, 2) or a higher readout bandwidth technique. The tilted view-angle method uses an additional gradient in the slice selection direction during readout. The high bandwidth technique increases the readout bandwidth and shortens the echo time (TE). High bandwidth and short echo times were implemented in both T(1)-weighted (T(1)W) turbo spin echo and turbo short tau inversion recovery (STIR) sequences. Both imaging techniques reduced the size of metal-induced image artifacts. The tilted view-angle method reduced the artifact to a greater degree but had inherent shortcomings. The reformatted images were blurred and shifted. The area of interest was often moved outside of the field of view, unless parameters were adjusted on the basis of a pre-scan calculation. The high readout bandwidth, short echo technique required no special preparation and reduced metal artifacts without image blurring. The combination of high-bandwidth, shorter echo turbo STIR and T(1)W turbo spin echo sequences with subtraction of pre- from post-contrast images allowed effective fat suppression without local field inhomogeneity affects. This greatly improved our ability to evaluate suspected disease near metallic implants in pediatric cancer patients.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10745138     DOI: 10.1016/s0730-725x(99)00135-6

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  23 in total

Review 1.  Surveillance Imaging Following Endovascular Aneurysm Repair.

Authors:  Nirnimesh Pandey; Harold I Litt
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

2.  Assessment of Magnetic Resonance Imaging Artifact Following Cervical Total Disc Arthroplasty.

Authors:  Amir H Fayyazi; Jennifer Taormina; David Svach; Jeff Stein; Nathaniel R Ordway
Journal:  Int J Spine Surg       Date:  2015-07-14

3.  MR imaging of the knee in patients with medial unicompartmental arthroplasty: comparison among sequences at 1.5 T.

Authors:  A Aliprandi; F Perona; M Bandirali; P Randelli; P Cabitza; F Sardanelli
Journal:  Radiol Med       Date:  2009-02-04       Impact factor: 3.469

4.  Reducing metallic artefacts in post-operative spinal imaging: slice encoding for metal artefact correction with dual-source parallel radiofrequency excitation MRI at 3.0 T.

Authors:  K D Song; Y C Yoon; J Park
Journal:  Br J Radiol       Date:  2013-07       Impact factor: 3.039

5.  Fully refocused multi-shot spatiotemporally encoded MRI: robust imaging in the presence of metallic implants.

Authors:  Noam Ben-Eliezer; Eddy Solomon; Elad Harel; Nava Nevo; Lucio Frydman
Journal:  MAGMA       Date:  2012-06-29       Impact factor: 2.310

Review 6.  Imaging pediatric bone sarcomas.

Authors:  Sue C Kaste
Journal:  Radiol Clin North Am       Date:  2011-06-16       Impact factor: 2.303

7.  PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging.

Authors:  Tim Hilgenfeld; Marcel Prager; Alexander Heil; Franz Sebastian Schwindling; Mathias Nittka; David Grodzki; Peter Rammelsberg; Martin Bendszus; Sabine Heiland
Journal:  Eur Radiol       Date:  2017-07-11       Impact factor: 5.315

8.  View angle tilting echo planar imaging for distortion correction.

Authors:  Sinyeob Ahn; Xiaoping P Hu
Journal:  Magn Reson Med       Date:  2011-12-28       Impact factor: 4.668

9.  Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration.

Authors:  Ricardo Otazo; Mathias Nittka; Mary Bruno; Esther Raithel; Christian Geppert; Soterios Gyftopoulos; Michael Recht; Leon Rybak
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 4.668

Review 10.  Malignant bone tumors and limb-salvage surgery in children.

Authors:  James S Meyer; William Mackenzie
Journal:  Pediatr Radiol       Date:  2004-06-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.