Literature DB >> 22209042

Femoral stem fracture and in vivo corrosion of retrieved modular femoral hips.

J Caitlin Huot Carlson1, Douglas W Van Citters, John H Currier, Amber M Bryant, Michael B Mayor, John P Collier.   

Abstract

A series of 78 retrieved modular hip devices were assessed for fretting and corrosion. Damage was common at both the head-neck junction (54% showing corrosion; 88% showing fretting) and at the stem-sleeve junction (88% corrosion; 65% fretting). Corrosion correlated to in vivo duration, patient activity, and metal (vs ceramic) femoral heads but did not correlate to head carbon content. Femoral stem fatigue fracture was observed in seven retrievals; all had severe corrosion, were under increased stress, and were in vivo longer than the non-fractured cohort. This study emphasizes the potential for stem fracture when small diameter femoral stems with large offsets are used in heavy and active patients. Designs which reduce fretting and corrosion in modular implants is warranted as patients demand longer lasting implants.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22209042     DOI: 10.1016/j.arth.2011.11.007

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  16 in total

1.  CORR Insights(®): Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.

Authors:  Philip C Noble
Journal:  Clin Orthop Relat Res       Date:  2015-08-21       Impact factor: 4.176

Review 2.  What is the trouble with trunnions?

Authors:  Christina I Esposito; Timothy M Wright; Stuart B Goodman; Daniel J Berry
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

3.  Stem-Sleeve Junction Failure of a Modular Femoral Hip System: a Retrieval Analysis.

Authors:  Feras Waly; Fahad H Abduljabbar; Trevor Gascoyne; Thomas R Turgeon; Olga Huk
Journal:  HSS J       Date:  2015-07-09

4.  Does Taper Angle Clearance Influence Fretting and Corrosion Damage at the Head-Stem Interface? A Matched Cohort Retrieval Study.

Authors:  Sevi B Kocagöz; Richard J Underwood; Shiril Sivan; Jeremy L Gilbert; Daniel W Macdonald; Judd S Day; Steven M Kurtz
Journal:  Semin Arthroplasty       Date:  2013-12-01

5.  Spontaneous Fractures of a Modern Modular Uncemented Femoral Stem.

Authors:  Chelsea N Koch; Laura Serrano Mateo; Stephen Kayiaros; Kevin A Cassidy; Seth A Jerabek; Alejandro Gonzalez Della Valle
Journal:  HSS J       Date:  2016-06-21

6.  Are titanium-on-titanium TiAl6V4 modular necks safe in total hip arthroplasty for non-overweight patients? Results of a prospective series at a minimum follow-up of 7 years.

Authors:  Matthieu Ollivier; Sébastien Parratte; Alexandre Galland; Alexandre Lunebourg; Jean-Noel Argenson
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-07-10

7.  Otto Aufranc Award: Large Heads Do Not Increase Damage at the Head-neck Taper of Metal-on-polyethylene Total Hip Arthroplasties.

Authors:  Georgios K Triantafyllopoulos; Marcella E Elpers; Jayme C Burket; Christina I Esposito; Douglas E Padgett; Timothy M Wright
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

8.  Failure of Emperion modular femoral stem with implant analysis.

Authors:  Benjamin M Stronach; Michael D Roach; Kenneth R St John
Journal:  Arthroplast Today       Date:  2016-01-11

9.  Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study.

Authors:  Steven M Kurtz; Sevi B Kocagöz; Josa A Hanzlik; Richard J Underwood; Jeremy L Gilbert; Daniel W MacDonald; Gwo-Chin Lee; Michael A Mont; Matthew J Kraay; Gregg R Klein; Javad Parvizi; Clare M Rimnac
Journal:  Clin Orthop Relat Res       Date:  2013-06-13       Impact factor: 4.176

10.  Fracture of the cemented femoral component following hemiarthroplasty in physically active patient: A case report.

Authors:  Deniz Cankaya; Burak Yoldas; Serdar Yılmaz; Ali Tecirli; Bulent Ozkurt
Journal:  J Orthop Case Rep       Date:  2015 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.