Literature DB >> 19104773

Comparison of the radiological results between fluoroscopy-assisted and navigation-guided total knee arthroplasty.

Young-Bok Jung1, Han-Jun Lee, Ho-Joong Jung, Kwang-Sup Song, Jae-Sung Lee, Jae Jun Yang.   

Abstract

The efficacy and accuracy of computer navigation have been proved during recent years. But most of recent studies focused on the coronal alignment in total knee arthroplasty and less on sagittal alignment. We retrospectively compared the results of the radiographs of 35 primary TKAs using a non-image based navigation system and 36 primary TKAs using fluoroscopy-assisted conventional technique. To compare the radiographic results, the following parameters were measured: mean mechanical femorotibial angle, mean femorotibial anatomical angle, mean coronal femoral component angle, mean coronal tibial component angle, mean sagittal femoral component angle, and mean sagittal tibial component angle. The navigation TKA showed better accuracy and consistency in mechanical axis deviation, coronal femoral component angle, and sagittal tibial component angle. The coronal tibial component position was acceptable in both groups. The navigation TKA markedly improved the restoration of mechanical axis, but not so much in sagittal femoral component position. The fluoroscopy-assisted conventional TKA had a tendency that femoral component was inserted in flexed position than in navigation TKA. Unlike the fluoroscopy-assisted conventional TKA, the femoral component was inserted in slightly extended position in the navigation TKA than expected. In conclusion, even though the use of navigation in TKAs help the surgeon to achieve good results, the surgeon should know the tendency of extension of the femoral component in sagittal plane to avoid anterior notching.

Entities:  

Mesh:

Year:  2008        PMID: 19104773     DOI: 10.1007/s00167-008-0682-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  39 in total

1.  Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty.

Authors:  J Novotny; M H Gonzalez; F M Amirouche; Y C Li
Journal:  J Arthroplasty       Date:  2001-08       Impact factor: 4.757

2.  [Navigation in knee endoprosthesis implantation--preliminary experiences and prospective comparative study with conventional implantation technique].

Authors:  R K Mielke; U Clemens; J H Jens; S Kershally
Journal:  Z Orthop Ihre Grenzgeb       Date:  2001 Mar-Apr

3.  [Navigated implantation of total knee endoprostheses--a comparative study with conventional instrumentation].

Authors:  J Y Jenny; C Boeri
Journal:  Z Orthop Ihre Grenzgeb       Date:  2001 Mar-Apr

4.  Bone cutting errors in total knee arthroplasty.

Authors:  Christopher Plaskos; Antony J Hodgson; Kevin Inkpen; Robert W McGraw
Journal:  J Arthroplasty       Date:  2002-09       Impact factor: 4.757

5.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique.

Authors:  H Bäthis; L Perlick; M Tingart; C Lüring; D Zurakowski; J Grifka
Journal:  J Bone Joint Surg Br       Date:  2004-07

6.  Importance of the lateral anatomic tibial slope as a guide to the tibial cut in total knee arthroplasty in Japanese patients.

Authors:  Takashi Kuwano; Ken Urabe; Hiromasa Miura; Ryuji Nagamine; Shuichi Matsuda; Masatoshi Satomura; Toshiaki Sasaki; Shuuji Sakai; Hiroshi Honda; Yukihide Iwamoto
Journal:  J Orthop Sci       Date:  2005       Impact factor: 1.601

7.  Computer-assisted surgery versus manual total knee arthroplasty: a case-controlled study.

Authors:  S David Stulberg; Mark A Yaffe; Samuel S Koo
Journal:  J Bone Joint Surg Am       Date:  2006-12       Impact factor: 5.284

8.  Coronal alignment after total knee replacement.

Authors:  R S Jeffery; R W Morris; R A Denham
Journal:  J Bone Joint Surg Br       Date:  1991-09

9.  Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations.

Authors:  J H Bargren; J D Blaha; M A Freeman
Journal:  Clin Orthop Relat Res       Date:  1983-03       Impact factor: 4.176

10.  Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty.

Authors:  C C Jiang; J N Insall
Journal:  Clin Orthop Relat Res       Date:  1989-11       Impact factor: 4.176

View more
  9 in total

1.  Intraoperative assessment of resected condyle thickness in total knee arthroplasty.

Authors:  Dae Kyung Bae; Sang Jun Song; Kyoung Ho Yoon; Jung Ho Noh; Chul Hee Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-24       Impact factor: 4.342

2.  Comparison of the tibiofemoral rotational alignment after mobile and fixed bearing total knee arthroplasty.

Authors:  Dongwook Kim; Sang Cheol Seong; Myung Chul Lee; Sahnghoon Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-06       Impact factor: 4.342

3.  Joint line changes after primary total knee arthroplasty: navigated versus non-navigated.

Authors:  A Jawhar; V Shah; S Sohoni; H P Scharf
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-06-22       Impact factor: 4.342

4.  The anterior trochlear line as a reference for femoral component positioning in total knee arthroplasty.

Authors:  Kazuki Morizane; Toshiaki Takahashi; Fumihiko Konishi; Haruyasu Yamamoto
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-02-03       Impact factor: 4.342

5.  Comparison of joint line position changes after primary bilateral total knee arthroplasty performed using the navigation-assisted measured gap resection or gap balancing techniques.

Authors:  Han Jun Lee; Jae Sung Lee; Ho Joong Jung; Kwang Sup Song; Jae Jun Yang; Chi Woo Park
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-03-23       Impact factor: 4.342

6.  Mid-term outcomes of computer-assisted total knee arthroplasty.

Authors:  Kazunari Ishida; Tomoyuki Matsumoto; Nobuhiro Tsumura; Seiji Kubo; Atsushi Kitagawa; Takaaki Chin; Tetsuhiro Iguchi; Masahiro Kurosaka; Ryosuke Kuroda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-01-14       Impact factor: 4.342

Review 7.  Computer-assisted total knee arthroplasty is currently of no proven clinical benefit: a systematic review.

Authors:  R Stephen J Burnett; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

8.  Conventional or navigated total knee arthroplasty affects sagittal component alignment.

Authors:  Ryo Sugama; Yukihide Minoda; Akio Kobayashi; Hiroyoshi Iwaki; Mitsuhiko Ikebuchi; Kunio Takaoka; Hiroaki Nakamura
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-01-20       Impact factor: 4.342

9.  Accuracy of anatomical references used for rotational alignment of tibial component in total knee arthroplasty.

Authors:  Namık Sahin; Teoman Atıcı; Alpaslan Öztürk; Güven Özkaya; Yüksel Özkan; Bülent Avcu
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-07-15       Impact factor: 4.342

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.