Literature DB >> 22179930

Extended healing validation of an artificial tendon to connect the quadriceps muscle to the Tibia: 180-day study.

Alan J Melvin1, Alan S Litsky, Joel L Mayerson, Keith Stringer, Natalia Juncosa-Melvin.   

Abstract

Whenever a tendon or its bone insertion is disrupted or removed, existing surgical techniques provide a temporary connection or scaffolding to promote healing, but the interface of living to non-living materials soon breaks down under the stress of these applications, if it must bear the load more than acutely. Patients are thus disabled whose prostheses, defect size, or mere anatomy limit the availability or outcomes of such treatments. Our group developed the OrthoCoupler™ device to join skeletal muscle to prosthetic or natural structures without this interface breakdown. In this study, the goat knee extensor mechanism (quadriceps tendon, patella, and patellar tendon) was removed from the right hind limb in 16 goats. The device connected the quadriceps muscle to a stainless steel bone plate on the tibia. Mechanical testing and histology specimens were collected from each operated leg and contralateral unoperated control legs at 180 days. Maximum forces in the operated leg (vs. unoperated) were 1,400 ± 93 N (vs. 1,179 ± 61 N), linear stiffnesses were 33 ± 3 N/mm (vs. 37 ± 4 N/mm), and elongations at failure were 92.1 ± 5.3 mm (vs. 68.4 ± 3.8 mm; mean ± SEM). Higher maximum forces (p = 0.02) and elongations at failure (p=0.008) of legs with the device versus unoperated controls were significant; linear stiffnesses were not (p=0.3). We believe this technology will yield improved procedures for clinical challenges in orthopedic oncology, revision arthroplasty, tendon transfer, and tendon injury reconstruction.
Copyright © 2011 Orthopaedic Research Society.

Entities:  

Mesh:

Year:  2011        PMID: 22179930      PMCID: PMC3330143          DOI: 10.1002/jor.22043

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  26 in total

1.  [Arthroscopic rotator cuff reconstruction].

Authors:  F Hoffmann; M Schiller; G Reif
Journal:  Orthopade       Date:  2000-10       Impact factor: 1.087

2.  ARTIFICIAL TENDONS. EARLY DEVELOPMENT AND APPLICATION.

Authors:  J HUNTER
Journal:  Am J Surg       Date:  1965-03       Impact factor: 2.565

3.  Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030.

Authors:  Steven Kurtz; Kevin Ong; Edmund Lau; Fionna Mowat; Michael Halpern
Journal:  J Bone Joint Surg Am       Date:  2007-04       Impact factor: 5.284

4.  Fiber technology for reliable repair of skeletal muscle.

Authors:  J E Franklin; J J Marler; M T Byrne; A J Melvin; S J Clarson; D B Melvin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-07       Impact factor: 3.368

5.  A soft-tissue coupling for wound closure.

Authors:  Alan J Melvin; David B Melvin; William J Kitzmiller; Kyle R Fath; Paul W Biddinger; Natalia Juncosa-Melvin
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2011-02-16       Impact factor: 3.368

6.  Insertion of the patella tendon after prosthetic replacement of the proximal tibia.

Authors:  T Ozaki; T Kunisada; A Kawai; Y Takahara; H Inoue
Journal:  Acta Orthop Scand       Date:  1999-10

Review 7.  Improved mechanism for capturing muscle power for circulatory support.

Authors:  Dennis R Trumble; David B Melvin; Mark T Byrne; James A Magovern
Journal:  Artif Organs       Date:  2005-09       Impact factor: 3.094

8.  Coupling of skeletal muscle to a prosthesis for circulatory support.

Authors:  D B Melvin; D L Glos; M C Abiog; A S Litsky
Journal:  ASAIO J       Date:  1997 Sep-Oct       Impact factor: 2.872

9.  An artificial tendon to connect the quadriceps muscle to the tibia.

Authors:  Alan Melvin; Alan Litsky; Joel Mayerson; Keith Stringer; David Melvin; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2011-04-25       Impact factor: 3.494

10.  An artificial tendon with durable muscle interface.

Authors:  Alan Melvin; Alan Litsky; Joel Mayerson; David Witte; David Melvin; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2010-02       Impact factor: 3.494

View more
  1 in total

1.  Implanted passive engineering mechanism improves hand function after tendon transfer surgery: a cadaver-based study.

Authors:  Katherine L Mardula; Ravi Balasubramanian; Christopher H Allan
Journal:  Hand (N Y)       Date:  2015-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.