Literature DB >> 19639642

An artificial tendon with durable muscle interface.

Alan Melvin1, Alan Litsky, Joel Mayerson, David Witte, David Melvin, Natalia Juncosa-Melvin.   

Abstract

A coupling mechanism that can permanently fix a forcefully contracting muscle to a bone anchor or any totally inert prosthesis would meet a serious need in orthopaedics. Our group developed the OrthoCoupler device to satisfy these demands. The objective of this study was to test OrthoCoupler's performance in vitro and in vivo in the goat semitendinosus tendon model. For in vitro evaluation, 40 samples were fatigue-tested, cycling at 10 load levels, n = 4 each. For in vivo evaluation, the semitendinosus tendon was removed bilaterally in eight goats. Left sides were reattached with an OrthoCoupler, and right sides were reattached using the Krackow stitch with #5 braided polyester sutures. Specimens were harvested 60 days postsurgery and assigned for biomechanics and histology. Fatigue strength of the devices in vitro was several times the contractile force of the semitendinosus muscle. The in vivo devices were built equivalent to two of the in vitro devices, providing an additional safety factor. In strength testing at necropsy, suture controls pulled out at 120.5 +/- 68.3 N, whereas each OrthoCoupler was still holding after the muscle tore, remotely, at 298 +/- 111.3 N (mean +/- SD) (p < 0.0003). Muscle tear strength was reached with the fiber-muscle composite produced in healing still soundly intact. This technology may be of value for orthopaedic challenges in oncology, revision arthroplasty, tendon transfer, and sports-injury reconstruction. (c) 2009 Orthopaedic Research Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19639642      PMCID: PMC2847839          DOI: 10.1002/jor.20971

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  26 in total

1.  A new skeletal muscle linear-pull energy convertor as a power source for prosthetic circulatory support devices [corrected].

Authors:  D J Farrar; J D Hill
Journal:  J Heart Lung Transplant       Date:  1992 Sep-Oct       Impact factor: 10.247

2.  Total femoral replacement.

Authors:  J Nerubay; A Katznelson; T Tichler; Z Rubinstein; B Morag; J J Bubis
Journal:  Clin Orthop Relat Res       Date:  1988-04       Impact factor: 4.176

3.  Comparative anatomy and histochemistry of human and canine latissimus dorsi muscle.

Authors:  O M Sola; L C Haines; B A Kakulas; T Ivey; D H Dillard; R Thomas; Y Shoji; Y Fujimura; L Dahm
Journal:  J Heart Transplant       Date:  1990 Mar-Apr

4.  Development of a reconstituted collagen tendon prosthesis. A preliminary implantation study.

Authors:  J D Goldstein; A J Tria; J P Zawadsky; Y P Kato; D Christiansen; F H Silver
Journal:  J Bone Joint Surg Am       Date:  1989-09       Impact factor: 5.284

5.  The use of Dexon as a replacement for the calcaneal tendon in sheep.

Authors:  C B Howard; B McKibbin; Z A Rális
Journal:  J Bone Joint Surg Br       Date:  1985-03

6.  Coupling of skeletal muscle to a prosthesis for circulatory support.

Authors:  D B Melvin; D L Glos; M C Abiog; A S Litsky
Journal:  ASAIO J       Date:  1997 Sep-Oct       Impact factor: 2.872

7.  Cardiac assistance with electrically stimulated skeletal muscle.

Authors:  S F Badylak; L Stevens; W Janas; M H Gray; L A Geddes; W D Voorhees
Journal:  Med Biol Eng Comput       Date:  1989-03       Impact factor: 2.602

8.  Tendons attached to prostheses by tendon-bone block fixation: an experimental study in dogs.

Authors:  F Gottsauner-Wolf; E L Egger; F M Schultz; F H Sim; E Y Chao
Journal:  J Orthop Res       Date:  1994-11       Impact factor: 3.494

9.  Ligament and tendon substitution with composite carbon fiber strands.

Authors:  D G Mendes; M Iusim; D Angel; A Rotem; D Mordehovich; M Roffman; S Lieberson; J Boss
Journal:  J Biomed Mater Res       Date:  1986 Jul-Aug

10.  Use of the Green transfer in treatment of patients with spastic cerebral palsy: 17-year experience.

Authors:  W R Beach; W B Strecker; J Coe; P R Manske; P L Schoenecker; L Dailey
Journal:  J Pediatr Orthop       Date:  1991 Nov-Dec       Impact factor: 2.324

View more
  3 in total

1.  Extended healing validation of an artificial tendon to connect the quadriceps muscle to the Tibia: 180-day study.

Authors:  Alan J Melvin; Alan S Litsky; Joel L Mayerson; Keith Stringer; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2011-12-16       Impact factor: 3.494

2.  An artificial tendon to connect the quadriceps muscle to the tibia.

Authors:  Alan Melvin; Alan Litsky; Joel Mayerson; Keith Stringer; David Melvin; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2011-04-25       Impact factor: 3.494

3.  Feasibility of Implanting a Foot-Ankle Endoprosthesis within Skin in a Rabbit Model of Transtibial Amputation.

Authors:  Dustin L Crouch; Patrick T Hall; Caleb Stubbs; Caroline Billings; Alisha P Pedersen; Bryce Burton; Cheryl B Greenacre; Stacy M Stephenson; David E Anderson
Journal:  Bioengineering (Basel)       Date:  2022-07-27
  3 in total