Literature DB >> 9360078

Coupling of skeletal muscle to a prosthesis for circulatory support.

D B Melvin1, D L Glos, M C Abiog, A S Litsky.   

Abstract

A durable bond between the end of skeletal muscles and prosthetic structures could, with appropriate linkage, allow circulatory support power by synchronous and/or sequential contraction of several in situ conditioned muscles. Potential advantages relative to a myoplasty wrap involve 1) less traumatic dissection, 2) efficient linear force development, 3) selectable contraction rate, 4) greater stroke work, 5) independent control of muscle pre-load and end diastolic pressure, and 6) independent control of duration of muscle tension and ejection time. However, no existing means of tissue-prosthetic bonding appears adequate. Practicality would demand that full tension bearing capacity by the bond take no longer than muscle conditioning. A prosthesis was developed to achieve those goals. As scaled for this study, it is made of 7,200-7,800 unspun, unplaited, 22 to 26 microns diameter polyester fibers swaged into four taper needles for weaving through distal muscle. The other end is formed into a polyurethane sheathed kernmantel cord for distal fixation. Devices were implanted in six 3 to 4 kg rabbits (unilateral posterior tibial tendon replacement, random side selection with contralateral dissection/closure controls), and their tensile strength was tested at 30 days. All healed well; leg movements were normal after 1 week. Limbs were frozen at -70 degrees C between death and testing. Control failure occurred at 243 +/- 94 N and experimental at 163 +/- 44 N (p = 0.065, t-test); highest estimated requirement was 17.2 N. Interface strength was adequate by 30 days. Continued investigations, addressing other questions, are warranted.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9360078

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Extended healing validation of an artificial tendon to connect the quadriceps muscle to the Tibia: 180-day study.

Authors:  Alan J Melvin; Alan S Litsky; Joel L Mayerson; Keith Stringer; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2011-12-16       Impact factor: 3.494

2.  An artificial tendon to connect the quadriceps muscle to the tibia.

Authors:  Alan Melvin; Alan Litsky; Joel Mayerson; Keith Stringer; David Melvin; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2011-04-25       Impact factor: 3.494

3.  An artificial tendon with durable muscle interface.

Authors:  Alan Melvin; Alan Litsky; Joel Mayerson; David Witte; David Melvin; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2010-02       Impact factor: 3.494

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.