Improved mechanism for capturing muscle power for circulatory support.

Dennis R Trumble1, David B Melvin, Mark T Byrne, James A Magovern.   

Abstract

Although it is now understood that trained skeletal muscle can generate enough steady-state power to provide significant circulatory support, there are currently no means by which to tap this endogenous energy source to aid the failing heart. To that end, an implantable muscle energy converter (MEC) has been constructed and its function has been improved to optimize durability, anatomic fit, and mechanical efficiency. Bench tests show that MEC transmission losses average less than 10% of total work input and that about 85% of this muscle power is successfully transferred to the working fluid of the pump. Results from canine implant trials confirm excellent biocompatibility and demonstrate that contractile work of the latissimus dorsi muscle-measured to 290 mJ/stroke in one dog-can be transmitted within the body at levels consistent with cardiac assist requirements. These findings suggest that muscle-powered cardiac assist devices are feasible and that efforts to further develop this technology are warranted.

Entities:  

Mesh:

Year:  2005        PMID: 16143010      PMCID: PMC4995101          DOI: 10.1111/j.1525-1594.2005.29108.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  27 in total

1.  Heart booster: a pericardial support device.

Authors:  R T Kung; M Rosenberg
Journal:  Ann Thorac Surg       Date:  1999-08       Impact factor: 4.330

2.  Circulatory support with a direct cardiac compression device: a less invasive approach with the AbioBooster device.

Authors:  M N Kavarana; D N Helman; M R Williams; A Barbone; J A Sanchez; E A Rose; M C Oz; M Milbocker; R T Kung
Journal:  J Thorac Cardiovasc Surg       Date:  2001-10       Impact factor: 5.209

Review 3.  Thoratec transcutaneous energy transformer system: a review and update.

Authors:  Thomas C Rintoul; Alexander Dolgin
Journal:  ASAIO J       Date:  2004 Jul-Aug       Impact factor: 2.872

4.  The effects of metals on a transcutaneous energy transmission system.

Authors:  D B Geselowitz; Q T Hoang; R P Gaumond
Journal:  IEEE Trans Biomed Eng       Date:  1992-09       Impact factor: 4.538

5.  Significance of impulse activity in the transformation of skeletal muscle type.

Authors:  S Salmons; F A Sréter
Journal:  Nature       Date:  1976-09-02       Impact factor: 49.962

Review 6.  Dynamic cardiomyoplasty for treatment of heart failure.

Authors:  A B Hill; R C Chiu
Journal:  Clin Cardiol       Date:  1989-12       Impact factor: 2.882

7.  Efficacy of a skeletal muscle-powered dynamic patch: Part 1. Left ventricular assistance.

Authors:  M Takahashi; T Misaki; G Watanabe; H Ohtake; Y Tsunezuka; M Wada; N Sakakibara; Y Matsunaga; M Kawasuji; Y Watanabe
Journal:  Ann Thorac Surg       Date:  1995-02       Impact factor: 4.330

8.  Ergometric studies of untrained skeletal muscle demonstrate feasibility of muscle-powered cardiac assistance.

Authors:  D R Trumble; J A Magovern
Journal:  J Appl Physiol (1985)       Date:  1994-10

9.  A muscle-powered energy delivery system and means for chronic in vivo testing.

Authors:  D R Trumble; J A Magovern
Journal:  J Appl Physiol (1985)       Date:  1999-06

10.  Ex vivo evaluation of a roller screw linear muscle actuator for an implantable ventricular assist device using trained and untrained latissimus dorsi muscles.

Authors:  Y Sasaki; G Chikazawa; M Nogawa; H Nishida; H Koyanagi; S Takatani
Journal:  Artif Organs       Date:  1999-03       Impact factor: 3.094

View more
  5 in total

1.  Extended healing validation of an artificial tendon to connect the quadriceps muscle to the Tibia: 180-day study.

Authors:  Alan J Melvin; Alan S Litsky; Joel L Mayerson; Keith Stringer; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2011-12-16       Impact factor: 3.494

2.  An artificial tendon to connect the quadriceps muscle to the tibia.

Authors:  Alan Melvin; Alan Litsky; Joel Mayerson; Keith Stringer; David Melvin; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2011-04-25       Impact factor: 3.494

3.  An artificial tendon with durable muscle interface.

Authors:  Alan Melvin; Alan Litsky; Joel Mayerson; David Witte; David Melvin; Natalia Juncosa-Melvin
Journal:  J Orthop Res       Date:  2010-02       Impact factor: 3.494

4.  Muscle-Powered Counterpulsation for Untethered, Non-Blood-Contacting Cardiac Support: A Path to Destination Therapy.

Authors:  Jooli Han; Edgar Aranda-Michel; Dennis R Trumble
Journal:  IEEE Trans Biomed Eng       Date:  2020-02-18       Impact factor: 4.538

5.  Left ventricular simulation of cardiac compression: Hemodynamics and regional mechanics.

Authors:  Edgar Aranda-Michel; Lewis K Waldman; Dennis R Trumble
Journal:  PLoS One       Date:  2019-10-31       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.