Literature DB >> 22163122

Mechanical behavior of fully expanded commercially available endovascular coronary stents.

Josip Tambaca1, Suncica Canic, Mate Kosor, R David Fish, David Paniagua.   

Abstract

The mechanical behavior of endovascular coronary stents influences their therapeutic efficacy. Through computational studies, researchers can analyze device performance and improve designs. We developed a 1-dimensional finite element method, net-based algorithm and used it to analyze the effects of radial loading and bending in commercially available stents. Our computational study included designs modeled on the Express, Cypher, Xience, and Palmaz stents.We found that stents that did not fully expand were less rigid than the fully expanded stents and, therefore, exhibited larger displacement. Stents with an open-cell design, such as Express-like or Xience-like stents, had a higher bending flexibility. Stents with in-phase circumferential rings, such as the Xience-like stent, had the smallest longitudinal extension when exposed to radial compression forces. Thus, the open-cell model that had in-phase circumferential rings connected by straight horizontal struts exhibited radial stiffness, bending flexibility, and the smallest change in stent length during radial forcing. The Palmaz-like stent was the most rigid of all. These findings are supported by clinical experience.Computer simulations of the mechanical properties of endovascular stents offer sophisticated insights into the mechanical behavior of different stent designs and should be used whenever possible to help physicians decide which stent is best for treating a given lesion. Our 1-dimensional finite element method model is incomparably simpler, faster, and more accurate than the classical 3-dimensional approaches. It can facilitate stent design and may aid in stent selection in the clinical setting.

Entities:  

Keywords:  Computer simulation; coronary artery disease; coronary restenosis; finite element analysis; materials testing; mathematical model; stents; stress, mechanical

Mesh:

Year:  2011        PMID: 22163122      PMCID: PMC3231552     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  22 in total

1.  Mechanical properties of metallic stents: how do these properties influence the choice of stent for specific lesions?

Authors:  J F Dyet; W G Watts; D F Ettles; A A Nicholson
Journal:  Cardiovasc Intervent Radiol       Date:  2000 Jan-Feb       Impact factor: 2.740

2.  Measuring arterial strain induced by endovascular stents.

Authors:  J C Squire; C Rogers; E R Edelman
Journal:  Med Biol Eng Comput       Date:  1999-11       Impact factor: 2.602

3.  Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events. Austrian Wiktor Stent Study Group and European Paragon Stent Investigators.

Authors:  M Gyöngyösi; P Yang; A Khorsand; D Glogar
Journal:  J Am Coll Cardiol       Date:  2000-05       Impact factor: 24.094

4.  Stent longitudinal flexibility: a comparison of 13 stent designs before and after balloon expansion.

Authors:  J A Ormiston; S R Dixon; M W Webster; P N Ruygrok; J T Stewart; I Minchington; T West
Journal:  Catheter Cardiovasc Interv       Date:  2000-05       Impact factor: 2.692

5.  Mechanical behaviour modelling of balloon-expandable stents.

Authors:  C Dumoulin; B Cochelin
Journal:  J Biomech       Date:  2000-11       Impact factor: 2.712

6.  Mechanical behavior of coronary stents investigated through the finite element method.

Authors:  Francesco Migliavacca; Lorenza Petrini; Maurizio Colombo; Ferdinando Auricchio; Riccardo Pietrabissa
Journal:  J Biomech       Date:  2002-06       Impact factor: 2.712

Review 7.  Stent design: implications for restenosis.

Authors:  Dougal R McLean; Neal L Eiger
Journal:  Rev Cardiovasc Med       Date:  2002       Impact factor: 2.930

8.  Increased risk of restenosis after placement of gold-coated stents: results of a randomized trial comparing gold-coated with uncoated steel stents in patients with coronary artery disease.

Authors:  A Kastrati; A Schömig; J Dirschinger; J Mehilli; N von Welser; J Pache; H Schühlen; T Schilling; C Schmitt; F J Neumann
Journal:  Circulation       Date:  2000-05-30       Impact factor: 29.690

9.  Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs.

Authors:  Gerhard A Holzapfel; Michael Stadler; Thomas C Gasser
Journal:  J Biomech Eng       Date:  2005-02       Impact factor: 2.097

10.  Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial.

Authors:  A Kastrati; J Mehilli; J Dirschinger; F Dotzer; H Schühlen; F J Neumann; M Fleckenstein; C Pfafferott; M Seyfarth; A Schömig
Journal:  Circulation       Date:  2001-06-12       Impact factor: 29.690

View more
  5 in total

1.  Behaviour of two typical stents towards a new stent evolution.

Authors:  M Simão; J M Ferreira; J Mora-Rodriguez; J Fragata; H M Ramos
Journal:  Med Biol Eng Comput       Date:  2016-09-26       Impact factor: 2.602

2.  In vivo degradation of copolymers prepared from L-lactide, 1,3-trimethylene carbonate and glycolide as coronary stent materials.

Authors:  Yuan Yuan; Xiaoyun Jin; Zhongyong Fan; Suming Li; Zhiqian Lu
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

3.  Waves and fluid-solid interaction in stented blood vessels.

Authors:  S Frecentese; L P Argani; A B Movchan; N V Movchan; G Carta; M L Wall
Journal:  Proc Math Phys Eng Sci       Date:  2018-01-17       Impact factor: 2.704

4.  Morphological and Physiological Characteristics of Ruptured Plaques in Native Arteries and Neoatherosclerotic Segments: An OCT-Based and Computational Fluid Dynamics Study.

Authors:  Chongying Jin; Ryo Torii; Anantharaman Ramasamy; Vincenzo Tufaro; Callum D Little; Klio Konstantinou; Yi Ying Tan; Nathan A L Yap; Jackie Cooper; Tom Crake; Constantinos O'Mahony; Roby Rakhit; Mohaned Egred; Javed Ahmed; Grigoris Karamasis; Lorenz Räber; Andreas Baumbach; Anthony Mathur; Christos V Bourantas
Journal:  Front Cardiovasc Med       Date:  2022-05-26

5.  Study of the behavior of a bell-shaped colonic self-expandable NiTi stent under peristaltic movements.

Authors:  Sergio Puértolas; Eduardo Bajador; José A Puértolas; Enrique López; Elena Ibarz; Luis Gracia; Antonio Herrera
Journal:  Biomed Res Int       Date:  2013-06-06       Impact factor: 3.411

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.