Literature DB >> 11401938

Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial.

A Kastrati1, J Mehilli, J Dirschinger, F Dotzer, H Schühlen, F J Neumann, M Fleckenstein, C Pfafferott, M Seyfarth, A Schömig.   

Abstract

BACKGROUND: Increased thrombogenicity and smooth muscle cell proliferative response induced by the metal struts compromise the advantages of coronary stenting. The objective of this randomized, multicenter study was to assess whether a reduced strut thickness of coronary stents is associated with improved follow-up angiographic and clinical results. METHODS AND
RESULTS: A total of 651 patients with coronary lesions situated in native vessels >2.8 mm in diameter were randomly assigned to receive 1 of 2 commercially available stents of comparable design but different thickness: 326 patients to the thin-strut stent (strut thickness of 50 microm) and 325 patients to the thick-strut stent (strut thickness of 140 microm). The primary end point was the angiographic restenosis (>/=50% diameter stenosis at follow-up angiography). Secondary end points were the incidence of reinterventions due to restenosis-induced ischemia and the combined rate of death and myocardial infarctions at 1 year. The incidence of angiographic restenosis was 15.0% in the thin-strut group and 25.8% in the thick-strut group (relative risk, 0.58; 95% CI, 0.39 to 0.87; P=0.003). Clinical restenosis was also significantly reduced, with a reintervention rate of 8.6% among thin-strut patients and 13.8% among thick-strut patients (relative risk, 0.62; 95% CI, 0.39 to 0.99; P=0.03). No difference was observed in the combined 1-year rate of death and myocardial infarction.
CONCLUSIONS: The use of a thinner-strut device is associated with a significant reduction of angiographic and clinical restenosis after coronary artery stenting. These findings may have relevant implications for the currently most widely used percutaneous coronary intervention.

Entities:  

Mesh:

Year:  2001        PMID: 11401938     DOI: 10.1161/01.cir.103.23.2816

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  119 in total

Review 1.  Drug-eluting stents for cardiovascular disorders.

Authors:  Juan F Granada; Grzegorz L Kaluza; Albert Raizner
Journal:  Curr Atheroscler Rep       Date:  2003-07       Impact factor: 5.113

2.  One-year clinical follow-up of a registry evaluating a percutaneous revascularisation strategy combining a pre-specified simple selection process with the use of a new thin-strut bare cobalt-chromium stent.

Authors:  P R Stella; G Pavlakis; P Agostoni; H M Nathoe; S Hoseyni Guyomi; B J Hamer; T X Wildbergh; P A Doevendans; E Van Belle
Journal:  Neth Heart J       Date:  2010-10       Impact factor: 2.380

3.  Mechanical behavior of fully expanded commercially available endovascular coronary stents.

Authors:  Josip Tambaca; Suncica Canic; Mate Kosor; R David Fish; David Paniagua
Journal:  Tex Heart Inst J       Date:  2011

Review 4.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

5.  Drug-eluting stents.

Authors:  Xiaodong Ma; Tim Wu; Michael P Robich; Xingwei Wang; Hao Wu; Bryan Buchholz; Stephen McCarthy
Journal:  Int J Clin Exp Med       Date:  2010-07-15

Review 6.  Emerging applications of nanotechnology for the diagnosis and management of vulnerable atherosclerotic plaques.

Authors:  Shann S Yu; Ryan A Ortega; Brendan W Reagan; John A McPherson; Hak-Joon Sung; Todd D Giorgio
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-08-10

7.  Comparison of the vessel healing process after everolimus-eluting stent and bare metal stent implantations in patients with ST-elevation myocardial infarction.

Authors:  Hideki Yano; Shigeo Horinaka; Manami Watahik; Tomoko Watanabe; Toshihiko Ishimitsu
Journal:  Heart Vessels       Date:  2018-11-03       Impact factor: 2.037

8.  Three-dimensional analysis of in vivo coronary stent--coronary artery interactions.

Authors:  Robert Liao; Nathan E Green; S Y James Chen; John C Messenger; Adam R Hansgen; Bertron M Groves; John D Carroll
Journal:  Int J Cardiovasc Imaging       Date:  2004-08       Impact factor: 2.357

9.  A first-in-man study of sirolimus-eluting, biodegradable polymer coated cobalt chromium stent in real life patients.

Authors:  Ashok Seth; Praveen Chandra; Nagendra S Chouhan; Ashok S Thakkar
Journal:  Indian Heart J       Date:  2012-07-27

10.  Comparison of neointimal hyperplasia and peri-stent vascular remodeling after implantation of everolimus-eluting versus sirolimus-eluting stents: intravascular ultrasound results from the EXCELLENT study.

Authors:  Young-Guk Ko; Dong-Ho Shin; Jung-Sun Kim; Byeong-Keuk Kim; Donghoon Choi; Myeong-Ki Hong; Hyeon-Cheol Gwon; Taehoon Ahn; In-Ho Chae; Jung-Han Yoon; Hyo-Soo Kim; Yangsoo Jang
Journal:  Int J Cardiovasc Imaging       Date:  2013-03-03       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.