Literature DB >> 22158925

Patency of branches after coverage with multiple telescoping flow-diverter devices: an in vivo study in rabbits.

D Dai1, Y H Ding, R Kadirvel, A E Rad, D A Lewis, D F Kallmes.   

Abstract

BACKGROUND AND
PURPOSE: The safety of placing multiple overlapped endoluminal flow diverters remains unclear because small eloquent branch arteries theoretically could become occluded by these devices. We placed single and multiple flow diverters over small branch arteries in rabbit aortas to determine the incidence of branch artery occlusion.
MATERIALS AND METHODS: Flow diverters (PED) were placed into 22 female New Zealand white rabbits abdominal aortas to cover ≥1 lumbar artery. Animals were divided into 3 groups (single PED, n = 9; double PED with 2 telescoped/overlapped devices, n = 7; and triple PED, with 3 telescoped/overlapped devices, n = 6) and were followed for 6 or 12 months. DSA was performed at follow-up. Subsequently, the tissue was processed, sectioned, and stained with H&E for histologic evaluation, histomorphometry, and analysis.
RESULTS: All the lumbar arteries covered by devices were clearly patent on angiography. Partial neointima covered the ostia of the branch vessels, but demonstrable patent lumens at the ostia in all cases were present. Neointima hyperplasia was minimal in the single-PED-group animals. The measured neointima was thicker for the double- and triple-PED groups compared with the single-PED group (P < .05). However, in all groups, the mean thickness of the neointima was ≤0.2 mm, and the percentage stenosis of the parent artery was <15% and 18% for 6 and 12 months, respectively. There was no significant inflammatory response in any group.
CONCLUSIONS: Small branch arteries remain patent even when covered by multiple overlapped PED flow-diverter devices.

Entities:  

Mesh:

Year:  2011        PMID: 22158925      PMCID: PMC7966178          DOI: 10.3174/ajnr.A2879

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  14 in total

1.  A second-generation, endoluminal, flow-disrupting device for treatment of saccular aneurysms.

Authors:  D F Kallmes; Y H Ding; D Dai; R Kadirvel; D A Lewis; H J Cloft
Journal:  AJNR Am J Neuroradiol       Date:  2009-04-15       Impact factor: 3.825

2.  Perforator infarction after placement of a pipeline flow-diverting stent for an unruptured A1 aneurysm.

Authors:  W J van Rooij; M Sluzewski
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-11       Impact factor: 3.825

3.  High-profile flow diverter (silk) implantation in the basilar artery: efficacy in the treatment of aneurysms and the role of the perforators.

Authors:  Zsolt Kulcsár; Ulrike Ernemann; Stephan G Wetzel; Alexander Bock; Sophia Goericke; Vasilis Panagiotopoulos; Michael Forsting; Daniel A Ruefenacht; Isabel Wanke
Journal:  Stroke       Date:  2010-07-08       Impact factor: 7.914

4.  The pipeline embolization device for the intracranial treatment of aneurysms trial.

Authors:  P K Nelson; P Lylyk; I Szikora; S G Wetzel; I Wanke; D Fiorella
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-09       Impact factor: 3.825

5.  Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device.

Authors:  I Szikora; Z Berentei; Z Kulcsar; M Marosfoi; Z S Vajda; W Lee; A Berez; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-11       Impact factor: 3.825

6.  Curative reconstruction of a giant midbasilar trunk aneurysm with the pipeline embolization device.

Authors:  David Fiorella; Michael E Kelly; Felipe C Albuquerque; Peter K Nelson
Journal:  Neurosurgery       Date:  2009-02       Impact factor: 4.654

7.  Bone formation in elastase-induced rabbit aneurysms embolized with platinum coils: report of 2 cases.

Authors:  D Dai; Y H Ding; R Kadirvel; D A Lewis; H J Cloft; D F Kallmes
Journal:  AJNR Am J Neuroradiol       Date:  2007 Jun-Jul       Impact factor: 3.825

8.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

9.  Endovascular treatment of a fusiform basilar artery aneurysm using multiple "in-stent stents". Technical note.

Authors:  R Webster Crowley; Avery J Evans; Neal F Kassell; Mary E Jensen; Aaron S Dumont
Journal:  J Neurosurg Pediatr       Date:  2009-06       Impact factor: 2.375

10.  A new endoluminal, flow-disrupting device for treatment of saccular aneurysms.

Authors:  David F Kallmes; Yong Hong Ding; Daying Dai; Ramanathan Kadirvel; Debra A Lewis; Harry J Cloft
Journal:  Stroke       Date:  2007-07-05       Impact factor: 7.914

View more
  15 in total

1.  Small pipes: preliminary experience with 3-mm or smaller pipeline flow-diverting stents for aneurysm repair prior to regulatory approval.

Authors:  A R Martin; J P Cruz; C O'Kelly; M Kelly; J Spears; T R Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-13       Impact factor: 3.825

2.  A New Aneurysm Occlusion Classification after the Impact of Flow Modification.

Authors:  H S Cekirge; I Saatci
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-27       Impact factor: 3.825

3.  Building multidevice pipeline constructs of favorable metal coverage: a practical guide.

Authors:  M Shapiro; E Raz; T Becske; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2014-03-27       Impact factor: 3.825

4.  Large animals in neurointerventional research: A systematic review on models, techniques and their application in endovascular procedures for stroke, aneurysms and vascular malformations.

Authors:  Andrea M Herrmann; Stephan Meckel; Matthew J Gounis; Leona Kringe; Edith Motschall; Christoph Mülling; Johannes Boltze
Journal:  J Cereb Blood Flow Metab       Date:  2019-02-07       Impact factor: 6.200

5.  Visual outcomes with flow-diverter stents covering the ophthalmic artery for treatment of internal carotid artery aneurysms.

Authors:  A Rouchaud; O Leclerc; Y Benayoun; S Saleme; Y Camilleri; F D'Argento; M-P Boncoeur; P-Y Robert; C Mounayer
Journal:  AJNR Am J Neuroradiol       Date:  2014-10-22       Impact factor: 3.825

6.  The Derivo Embolization Device, a Second-Generation Flow Diverter for the Treatment of Intracranial Aneurysms, Evaluated in an Elastase-Induced Aneurysm Model.

Authors:  D Ley; R Mühl-Benninghaus; U Yilmaz; H Körner; G F M Cattaneo; W Mailänder; Y-J Kim; B Scheller; W Reith; A Simgen
Journal:  Clin Neuroradiol       Date:  2015-12-23       Impact factor: 3.649

7.  Posterior Inferior Cerebellar Artery Patency after Flow-Diverting Stent Treatment.

Authors:  M R Levitt; M S Park; F C Albuquerque; K Moon; M Y S Kalani; C G McDougall
Journal:  AJNR Am J Neuroradiol       Date:  2015-10-01       Impact factor: 3.825

8.  Extra-aneurysmal flow modification following pipeline embolization device implantation: focus on regional branches, perforators, and the parent vessel.

Authors:  G Gascou; K Lobotesis; H Brunel; P Machi; C Riquelme; O Eker; A Bonafé; V Costalat
Journal:  AJNR Am J Neuroradiol       Date:  2014-12-18       Impact factor: 3.825

9.  Pipeline embolization device in aneurysmal subarachnoid hemorrhage.

Authors:  J P Cruz; C O'Kelly; M Kelly; J H Wong; W Alshaya; A Martin; J Spears; T R Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-11       Impact factor: 3.825

10.  Evaluation of occurring complications after flow diverter treatment of elastase-induced aneurysm in rabbits using micro-CT and MRI at 9.4 T.

Authors:  Andreas Simgen; Désirée Ley; Christian Roth; Giorgio Franco Maria Cattaneo; Ruben Mühl-Benninghaus; Andreas Müller; Heiko Körner; Yoo-Jin Kim; Bruno Scheller; Wolfgang Reith; Umut Yilmaz
Journal:  Neuroradiology       Date:  2016-07-25       Impact factor: 2.804

View more