Literature DB >> 22157571

Measurements of microkeratome cuts in donor corneas with ultrasound and optical coherence tomography.

Maolong Tang1, Donald Ward, Jose Luiz Branco Ramos, Yan Li, Paulo Schor, David Huang.   

Abstract

PURPOSE: To evaluate optical coherence tomography (OCT) in the measurement of donor corneas in preparation for endothelial keratoplasty.
METHODS: Donor corneas were imaged by OCT while immersed in preservation medium. Central corneal thickness (CCT) was measured by OCT from the Bowman layer to the endothelium. The corneas were then mounted on an artificial anterior chamber, and the epithelium was removed. Ultrasound pachymetry (USP) was used to measure CCT just before sectioning with a microkeratome. The central graft thickness (CGT) was measured by USP. The graft was then returned to the medium and imaged by OCT.
RESULTS: The study included 154 donor corneas. The average CCT measured by OCT (550 ± 63 μm) was thicker (P < 0.001) than that measured by USP (507 ± 54 μm). Similarly, the CGT measured by OCT (158 ± 41 μm) was thicker (P = 0.0005) than that measured by USP (153 ± 38 μm). The predictability of cut depth, as assessed by pooled standard deviation (SD), was better (P = 0.023) for USP (41 μm) compared with OCT (48 μm). The graft was thicker (P < 0.001) peripherally than centrally in OCT images. The predictability of cut depth by OCT was better (P < 0.001) for corneas thinner than 600 μm (SD = 45.6 μm) compared with those thicker than 600 μm (SD = 86.9 μm).
CONCLUSIONS: The donor corneal measurements by OCT were not as predictable as those by USP. The predictability of graft thickness, however, could be optimized using OCT to select for corneas thinner than 600 μm and then using immediate precut USP to set the microkeratome depth. A graft thickness profile measured by OCT could be useful to the surgeon.

Entities:  

Mesh:

Year:  2012        PMID: 22157571      PMCID: PMC3259255          DOI: 10.1097/ICO.0b013e318221cef8

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  12 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Corneal function after storage in dexsol or optisol.

Authors:  R J Walkenbach; F Boney; G S Ye
Journal:  Invest Ophthalmol Vis Sci       Date:  1992-07       Impact factor: 4.799

3.  The effect of age on normal human optic nerve fiber number and diameter.

Authors:  M X Repka; H A Quigley
Journal:  Ophthalmology       Date:  1989-01       Impact factor: 12.079

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Random-effects models for longitudinal data.

Authors:  N M Laird; J H Ware
Journal:  Biometrics       Date:  1982-12       Impact factor: 2.571

6.  High-speed optical coherence tomography of corneal opacities.

Authors:  Rahul N Khurana; Yan Li; Maolong Tang; Michael M Lai; David Huang
Journal:  Ophthalmology       Date:  2007-02-20       Impact factor: 12.079

7.  Corneal pachymetry mapping with high-speed optical coherence tomography.

Authors:  Yan Li; Raj Shekhar; David Huang
Journal:  Ophthalmology       Date:  2006-05       Impact factor: 12.079

8.  Corneal flap thickness with the Moria M2 single-use head 90 microkeratome.

Authors:  Anne Huhtala; Juhani Pietilä; Petri Mäkinen; Sakari Suominen; Matti Seppänen; Hannu Uusitalo
Journal:  Acta Ophthalmol Scand       Date:  2007-06

9.  Precut tissue in Descemet's stripping automated endothelial keratoplasty donor characteristics and early postoperative complications.

Authors:  Edwin S Chen; Mark A Terry; Neda Shamie; Karen L Hoar; Daniel J Friend
Journal:  Ophthalmology       Date:  2008-01-25       Impact factor: 12.079

10.  Agreement among 3 methods to measure corneal thickness: ultrasound pachymetry, Orbscan II, and Visante anterior segment optical coherence tomography.

Authors:  Emmy Y M Li; Shaheeda Mohamed; Christopher K S Leung; Srinivas K Rao; Arthur C K Cheng; Carol Y L Cheung; Dennis S C Lam
Journal:  Ophthalmology       Date:  2007-05-15       Impact factor: 12.079

View more
  5 in total

1.  Evaluating DSAEK graft deturgescence in preservation medium after microkeratome cut with optical coherence tomography.

Authors:  Maolong Tang; Christopher Stoeger; Joshua Galloway; Jeffrey Holiman; Matthew R Bald; David Huang
Journal:  Cornea       Date:  2013-06       Impact factor: 2.651

Review 2.  Eye-bank preparation of endothelial tissue.

Authors:  Grace E Boynton; Maria A Woodward
Journal:  Curr Opin Ophthalmol       Date:  2014-07       Impact factor: 3.761

3.  Preparation of endothelial keratoplasty lenticules with Gebauer SLc Original versus Moria CBm Carriazo-Barraquer and Moria One-Use Plus microkeratomes.

Authors:  Mozhgan Rezaei Kanavi; Tahereh Chamani; Bahareh Kheiri; Mohammad Ali Javadi
Journal:  Indian J Ophthalmol       Date:  2020-05       Impact factor: 1.848

4.  Comparison of Artificial Anterior Chamber Internal Pressures and Cutting Systems for Descemet's Stripping Automated Endothelial Keratoplasty.

Authors:  Sota Nishisako; Dai Aoki; Chiaki Sasaki; Kazunari Higa; Jun Shimazaki
Journal:  Transl Vis Sci Technol       Date:  2018-11-27       Impact factor: 3.283

5.  Use of fourier-domain optical coherence tomography to evaluate anterior stromal opacities in donor corneas.

Authors:  Matthew R Bald; Christopher Stoeger; Joshua Galloway; Maolong Tang; Jeffrey Holiman; David Huang
Journal:  J Ophthalmol       Date:  2013-03-28       Impact factor: 1.909

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.