Literature DB >> 18221999

Precut tissue in Descemet's stripping automated endothelial keratoplasty donor characteristics and early postoperative complications.

Edwin S Chen1, Mark A Terry, Neda Shamie, Karen L Hoar, Daniel J Friend.   

Abstract

PURPOSE: To describe donor characteristics of eye bank-prepared precut tissue used in Descemet's stripping automated endothelial keratoplasty (DSAEK) and report any increase in immediate postoperative complications associated with its use.
DESIGN: Prospective, noncomparative, interventional case series. PARTICIPANTS: One hundred donor corneas deemed appropriate for transplant and 100 eyes undergoing DSAEK for endothelial dysfunction.
METHODS: Precut donor tissue was evaluated in a prospective study of 100 consecutive cases of DSAEK surgery. Donor characteristics and the immediate postoperative complications of donor tissue dislocation and graft failure with the use of precut tissue were recorded and analyzed. MAIN OUTCOME MEASURES: Preoperative donor characteristics (age, time from death to preservation, time from death to implantation, time from cut to implantation, residual stromal bed thickness, pre- and postcut endothelial density), rate of dislocation, and rate of primary graft failure.
RESULTS: Average donor age was 57.6+/-10.8 years, average time from death to preservation was 9.8+/-3.2 hours, average time from death to implantation was 94.5+/-33.5 hours, and average time from cut to implantation was 26.0+/-17.4 hours. The average residual stromal bed thickness was 169+/-36 microns. The average endothelial cell density (ECD) after cutting was 2709+/-292 cells/mm(2) (n = 100). In the subgroup of donors in whom pre-resection and postresection endothelial cell densities were available (n = 80), the average ECD before cutting was 2743+/-253 cells/mm(2) and the average ECD after cutting was 2644+/-257 cells/mm(2). This average cell loss of 3.7% was statistically significant (P<0.001). There was only 1 dislocation in this entire series of 100 eyes. There were no primary graft failures.
CONCLUSION: The use of precut tissue in DSAEK had a low rate of early postoperative complications such as graft dislocation (1%) and primary graft failure (0%). A wide range of donor characteristics such as donor age, death to transplantation time, precutting to transplantation time, and donor lenticule thickness resulted in excellent adhesion of the tissue and clear grafts.

Entities:  

Mesh:

Year:  2008        PMID: 18221999     DOI: 10.1016/j.ophtha.2007.11.032

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  22 in total

1.  Successful Descemet's stripping automated endothelial keratoplasty for congenital hereditary endothelial dystrophy in a pediatric patient.

Authors:  Jeffrey M Goshe; Jennifer Y Li; Mark A Terry
Journal:  Int Ophthalmol       Date:  2012-01-25       Impact factor: 2.031

2.  Endothelial keratoplasty: a comparison of complication rates and endothelial survival between precut tissue and surgeon-cut tissue by a single DSAEK surgeon.

Authors:  Mark A Terry
Journal:  Trans Am Ophthalmol Soc       Date:  2009-12

Review 3.  Corneal endothelial autocrine trophic factor VIP in a mechanism-based strategy to enhance human donor cornea preservation for transplantation.

Authors:  Shay-Whey Margaret Koh
Journal:  Exp Eye Res       Date:  2011-10-25       Impact factor: 3.467

4.  Effect of Graft Attachment Status and Intraocular Pressure on Descemet Stripping Automated Endothelial Keratoplasty Outcomes in the Cornea Preservation Time Study.

Authors:  Anthony J Aldave; Mark A Terry; Loretta B Szczotka-Flynn; Wendi Liang; Allison R Ayala; Maureen G Maguire; Robert C O'Brien; Beth Ann Benetz; John E Bokosky; Steven P Dunn; Thomas E Gillette; Kristin M Hammersmith; David R Hardten; Bennie H Jeng; Marc F Jones; Richard L Lindstrom; Kenneth J Maverick; Verinder S Nirankari; Matthew S Oliva; Irving M Raber; Christopher J Rapuano; George O D Rosenwasser; Kevin W Ross; John W Seedor; Neda Shamie; Christopher G Stoeger; Shachar Tauber; Woodford S Van Meter; David D Verdier; Jonathan H Lass
Journal:  Am J Ophthalmol       Date:  2019-03-06       Impact factor: 5.258

5.  Analysis of posterior donor corneal parameters 1 year after Descemet stripping automated endothelial keratoplasty (DSAEK) triple procedure.

Authors:  Marco Lombardo; Mark A Terry; Giuseppe Lombardo; David D Boozer; Sebastiano Serrao; Pietro Ducoli
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-01-29       Impact factor: 3.117

6.  Measurements of microkeratome cuts in donor corneas with ultrasound and optical coherence tomography.

Authors:  Maolong Tang; Donald Ward; Jose Luiz Branco Ramos; Yan Li; Paulo Schor; David Huang
Journal:  Cornea       Date:  2012-02       Impact factor: 2.651

7.  Evaluating DSAEK graft deturgescence in preservation medium after microkeratome cut with optical coherence tomography.

Authors:  Maolong Tang; Christopher Stoeger; Joshua Galloway; Jeffrey Holiman; Matthew R Bald; David Huang
Journal:  Cornea       Date:  2013-06       Impact factor: 2.651

8.  Precut cornea for Descemet's stripping endothelial keratoplasty: experience at a single eye bank.

Authors:  Ashik Mohamed; Sunita Chaurasia; Venkataswamy Chandragiri; Srinivas Kandhibanda; Srinivas Gunnam; Prashant Garg
Journal:  Int Ophthalmol       Date:  2016-07-20       Impact factor: 2.031

9.  Quantitative Analysis of Endothelial Cell Loss in Preloaded Descemet Membrane Endothelial Keratoplasty Grafts.

Authors:  Meraf A Wolle; David L DeMill; Lauren Johnson; Stephen I Lentz; Maria A Woodward; Shahzad I Mian
Journal:  Cornea       Date:  2017-11       Impact factor: 2.651

10.  Influence of preoperative donor tissue characteristics on graft dislocation rate after Descemet stripping automated endothelial keratoplasty.

Authors:  Christopher T Hood; Maria A Woodward; Michael L Bullard; Roni M Shtein
Journal:  Cornea       Date:  2013-12       Impact factor: 2.651

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.