Literature DB >> 22155289

Automatic alignment and reconstruction of images for soft X-ray tomography.

Dilworth Y Parkinson1, Christian Knoechel, Chao Yang, Carolyn A Larabell, Mark A Le Gros.   

Abstract

Soft X-ray tomography (SXT) is a powerful imaging technique that generates quantitative, 3D images of the structural organization of whole cells in a near-native state. SXT is also a high-throughput imaging technique. At the National Center for X-ray Tomography (NCXT), specimen preparation and image collection for tomographic reconstruction of a whole cell require only minutes. Aligning and reconstructing the data, however, take significantly longer. Here we describe a new component of the high throughput computational pipeline used for processing data at the NCXT. We have developed a new method for automatic alignment of projection images that does not require fiducial markers or manual interaction with the software. This method has been optimized for SXT data sets, which routinely involve full rotation of the specimen. This software gives users of the NCXT SXT instrument a new capability - virtually real-time initial 3D results during an imaging experiment, which can later be further refined. The new code, Automatic Reconstruction 3D (AREC3D), is also fast, reliable, and robust. The fundamental architecture of the code is also adaptable to high performance GPU processing, which enables significant improvements in speed and fidelity. Copyright Â
© 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 22155289      PMCID: PMC3288662          DOI: 10.1016/j.jsb.2011.11.027

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  32 in total

1.  Refinement procedure for the image alignment in high-resolution electron tomography.

Authors:  L Houben; M Bar Sadan
Journal:  Ultramicroscopy       Date:  2011-06-21       Impact factor: 2.689

2.  Three-dimensional cellular ultrastructure resolved by X-ray microscopy.

Authors:  Gerd Schneider; Peter Guttmann; Stefan Heim; Stefan Rehbein; Florian Mueller; Kunio Nagashima; J Bernard Heymann; Waltraud G Müller; James G McNally
Journal:  Nat Methods       Date:  2010-11-14       Impact factor: 28.547

3.  Unified 3-D structure and projection orientation refinement using quasi-Newton algorithm.

Authors:  Chao Yang; Esmond G Ng; Pawel A Penczek
Journal:  J Struct Biol       Date:  2005-01       Impact factor: 2.867

4.  A resolution criterion for electron tomography based on cross-validation.

Authors:  Giovanni Cardone; Kay Grünewald; Alasdair C Steven
Journal:  J Struct Biol       Date:  2005-08       Impact factor: 2.867

5.  Tilt-series and electron microscope alignment for the correction of the non-perpendicularity of beam and tilt-axis.

Authors:  Daniel Castaño Díez; Anja Seybert; Achilleas S Frangakis
Journal:  J Struct Biol       Date:  2006-01-26       Impact factor: 2.867

Review 6.  High performance computing in structural determination by electron cryomicroscopy.

Authors:  J J Fernández
Journal:  J Struct Biol       Date:  2008-07-16       Impact factor: 2.867

7.  Performance evaluation of image processing algorithms on the GPU.

Authors:  Daniel Castaño-Díez; Dominik Moser; Andreas Schoenegger; Sabine Pruggnaller; Achilleas S Frangakis
Journal:  J Struct Biol       Date:  2008-07-24       Impact factor: 2.867

8.  A marker-free alignment method for electron tomography.

Authors:  Y Liu; P A Penczek; B F McEwen; J Frank
Journal:  Ultramicroscopy       Date:  1995-06       Impact factor: 2.689

9.  The correlation averaging of a regularly arranged bacterial cell envelope protein.

Authors:  W O Saxton; W Baumeister
Journal:  J Microsc       Date:  1982-08       Impact factor: 1.758

10.  Marker-free image registration of electron tomography tilt-series.

Authors:  Carlos Oscar Sanchez Sorzano; Cédric Messaoudi; Matthias Eibauer; J R Bilbao-Castro; R Hegerl; S Nickell; S Marco; J M Carazo
Journal:  BMC Bioinformatics       Date:  2009-04-27       Impact factor: 3.169

View more
  29 in total

1.  Biological soft X-ray tomography on beamline 2.1 at the Advanced Light Source.

Authors:  Mark A Le Gros; Gerry McDermott; Bertrand P Cinquin; Elizabeth A Smith; Myan Do; Weilun L Chao; Patrick P Naulleau; Carolyn A Larabell
Journal:  J Synchrotron Radiat       Date:  2014-10-01       Impact factor: 2.616

2.  Analysis of ER-mitochondria contacts using correlative fluorescence microscopy and soft X-ray tomography of mammalian cells.

Authors:  Kirstin D Elgass; Elizabeth A Smith; Mark A LeGros; Carolyn A Larabell; Michael T Ryan
Journal:  J Cell Sci       Date:  2015-06-22       Impact factor: 5.285

Review 3.  Imaging and characterizing cells using tomography.

Authors:  Myan Do; Samuel A Isaacson; Gerry McDermott; Mark A Le Gros; Carolyn A Larabell
Journal:  Arch Biochem Biophys       Date:  2015-01-17       Impact factor: 4.013

4.  Joint iterative reconstruction and 3D rigid alignment for X-ray tomography.

Authors:  K Pande; J J Donatelli; D Y Parkinson; H Yan; J A Sethian
Journal:  Opt Express       Date:  2022-03-14       Impact factor: 3.894

5.  Soft X-ray tomography to map and quantify organelle interactions at the mesoscale.

Authors:  Valentina Loconte; Jitin Singla; Angdi Li; Jian-Hua Chen; Axel Ekman; Gerry McDermott; Andrej Sali; Mark Le Gros; Kate L White; Carolyn A Larabell
Journal:  Structure       Date:  2022-02-10       Impact factor: 5.871

Review 6.  Mesoscale imaging with cryo-light and X-rays: Larger than molecular machines, smaller than a cell.

Authors:  Axel A Ekman; Jian-Hua Chen; Jessica Guo; Gerry McDermott; Mark A Le Gros; Carolyn A Larabell
Journal:  Biol Cell       Date:  2016-11-14       Impact factor: 4.458

7.  PSF correction in soft X-ray tomography.

Authors:  Axel Ekman; Venera Weinhardt; Jian-Hua Chen; Gerry McDermott; Mark A Le Gros; Carolyn Larabell
Journal:  J Struct Biol       Date:  2018-06-13       Impact factor: 2.867

8.  Correlative microscopy methods that maximize specimen fidelity and data completeness, and improve molecular localization capabilities.

Authors:  Elizabeth A Smith; Bertrand P Cinquin; Gerry McDermott; Mark A Le Gros; Dilworth Y Parkinson; Hong Tae Kim; Carolyn A Larabell
Journal:  J Struct Biol       Date:  2013-03-24       Impact factor: 2.867

9.  X-ray computed tomography using partially coherent Fresnel diffraction with application to an optical fiber.

Authors:  Zachary H Levine; Edward J Garboczi; Adele P Peskin; Axel A Ekman; Elisabeth Mansfield; Jason D Holm
Journal:  Opt Express       Date:  2021-01-18       Impact factor: 3.894

Review 10.  Cryo-soft X-ray tomography: a journey into the world of the native-state cell.

Authors:  Raffaella Carzaniga; Marie-Charlotte Domart; Lucy M Collinson; Elizabeth Duke
Journal:  Protoplasma       Date:  2013-11-22       Impact factor: 3.356

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.