Literature DB >> 7571119

A marker-free alignment method for electron tomography.

Y Liu1, P A Penczek, B F McEwen, J Frank.   

Abstract

In electron tomography of biological specimens, fiducial markers are normally used to achieve accurate alignment of the input projections. We address the problem of alignment of projections from objects that are freely supported and do not permit the use of markers. To this end we present a new alignment algorithm for single-axis tilt geometry based on the principle of Fourier-space common lines. An iterative scheme has been developed to overcome the noise-sensitivity of the common-line method. This algorithm was used to align a data set that was not amenable to alignment with fiducial markers.

Mesh:

Year:  1995        PMID: 7571119     DOI: 10.1016/0304-3991(95)00006-m

Source DB:  PubMed          Journal:  Ultramicroscopy        ISSN: 0304-3991            Impact factor:   2.689


  15 in total

Review 1.  Reconstructing virus structures from nanometer to near-atomic resolutions with cryo-electron microscopy and tomography.

Authors:  Juan Chang; Xiangan Liu; Ryan H Rochat; Matthew L Baker; Wah Chiu
Journal:  Adv Exp Med Biol       Date:  2012       Impact factor: 2.622

2.  Automatic alignment and reconstruction of images for soft X-ray tomography.

Authors:  Dilworth Y Parkinson; Christian Knoechel; Chao Yang; Carolyn A Larabell; Mark A Le Gros
Journal:  J Struct Biol       Date:  2011-12-02       Impact factor: 2.867

3.  Joint iterative reconstruction and 3D rigid alignment for X-ray tomography.

Authors:  K Pande; J J Donatelli; D Y Parkinson; H Yan; J A Sethian
Journal:  Opt Express       Date:  2022-03-14       Impact factor: 3.894

4.  TomoJ: tomography software for three-dimensional reconstruction in transmission electron microscopy.

Authors:  Cédric Messaoudii; Thomas Boudier; Carlos Oscar Sanchez Sorzano; Sergio Marco
Journal:  BMC Bioinformatics       Date:  2007-08-06       Impact factor: 3.169

5.  Alignment Solution for CT Image Reconstruction using Fixed Point and Virtual Rotation Axis.

Authors:  Kyungtaek Jun; Seokhwan Yoon
Journal:  Sci Rep       Date:  2017-01-25       Impact factor: 4.379

6.  The advent of structural biology in situ by single particle cryo-electron tomography.

Authors:  Jesús G Galaz-Montoya; Steven J Ludtke
Journal:  Biophys Rep       Date:  2017-05-29

7.  Fast Projection Matching for X-ray Tomography.

Authors:  Chun-Chieh Wang; Cheng-Cheng Chiang; Biqing Liang; Gung-Chian Yin; Yi-Tse Weng; Liang-Chi Wang
Journal:  Sci Rep       Date:  2017-06-16       Impact factor: 4.379

8.  Rapid alignment of nanotomography data using joint iterative reconstruction and reprojection.

Authors:  Doğa Gürsoy; Young P Hong; Kuan He; Karl Hujsak; Seunghwan Yoo; Si Chen; Yue Li; Mingyuan Ge; Lisa M Miller; Yong S Chu; Vincent De Andrade; Kai He; Oliver Cossairt; Aggelos K Katsaggelos; Chris Jacobsen
Journal:  Sci Rep       Date:  2017-09-18       Impact factor: 4.379

9.  A fast fiducial marker tracking model for fully automatic alignment in electron tomography.

Authors:  Renmin Han; Fa Zhang; Xin Gao
Journal:  Bioinformatics       Date:  2018-03-01       Impact factor: 6.937

10.  Alignment theory of parallel-beam computed tomography image reconstruction for elastic-type objects using virtual focusing method.

Authors:  Kyungtaek Jun; Dongwook Kim
Journal:  PLoS One       Date:  2018-06-15       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.