Tilt-series and electron microscope alignment for the correction of the non-perpendicularity of beam and tilt-axis.

Daniel Castaño Díez1, Anja Seybert, Achilleas S Frangakis.   

Abstract

In electron tomography the sample is tilted in the electron microscope and projections are recorded at different viewing angles. In the correct geometric setting, the tilt-axis of the object under scrutiny is perpendicular to the beam direction. However, we will demonstrate that this does not necessarily apply to all electron microscopes equipped with the default column alignment. The resulting effect is that a conical tilt is performed, which has to be considered in the reconstruction to avoid artifacts and to improve the resolution. A novel solution, with significantly improved convergence properties, will be introduced for calculating the three-dimensional marker model, which is necessary for the alignment of the tilt-series. Thereby, the angle between the beam direction and the tilt-axis is calculated, together with other geometrical distortions, like magnification and rotation changes, and incorporated in the reconstruction. Hereby, artifacts can be eliminated at the image processing basis, and the resolution can be significantly improved at the medium to high range frequencies. Synthetical and real data are used to demonstrate the obstructions caused by this effect and the quality improvement of the reconstructions. Finally, we also present a way to align the hardware of the microscope to correct for the non-perpendicularity between the beam direction and the tilt-axis, which is specifically tailored for tomographic applications.

Mesh:

Year:  2006        PMID: 16503168     DOI: 10.1016/j.jsb.2005.12.009

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  7 in total

1.  Computational resources for cryo-electron tomography in Bsoft.

Authors:  J Bernard Heymann; Giovanni Cardone; Dennis C Winkler; Alasdair C Steven
Journal:  J Struct Biol       Date:  2007-08-11       Impact factor: 2.867

2.  Marker-free dual-axis tilt series alignment.

Authors:  Hanspeter Winkler; Kenneth A Taylor
Journal:  J Struct Biol       Date:  2013-02-19       Impact factor: 2.867

3.  Automatic alignment and reconstruction of images for soft X-ray tomography.

Authors:  Dilworth Y Parkinson; Christian Knoechel; Chao Yang; Carolyn A Larabell; Mark A Le Gros
Journal:  J Struct Biol       Date:  2011-12-02       Impact factor: 2.867

4.  High-performance iterative electron tomography reconstruction with long-object compensation using graphics processing units (GPUs).

Authors:  Wei Xu; Fang Xu; Mel Jones; Bettina Keszthelyi; John Sedat; David Agard; Klaus Mueller
Journal:  J Struct Biol       Date:  2010-04-04       Impact factor: 2.867

5.  LEM2 recruits CHMP7 for ESCRT-mediated nuclear envelope closure in fission yeast and human cells.

Authors:  Mingyu Gu; Dollie LaJoie; Opal S Chen; Alexander von Appen; Mark S Ladinsky; Michael J Redd; Linda Nikolova; Pamela J Bjorkman; Wesley I Sundquist; Katharine S Ullman; Adam Frost
Journal:  Proc Natl Acad Sci U S A       Date:  2017-02-27       Impact factor: 11.205

6.  Cryo-tomography tilt-series alignment with consideration of the beam-induced sample motion.

Authors:  Jose-Jesus Fernandez; Sam Li; Tanmay A M Bharat; David A Agard
Journal:  J Struct Biol       Date:  2018-02-03       Impact factor: 2.867

7.  Desmosome architecture derived from molecular dynamics simulations and cryo-electron tomography.

Authors:  Mateusz Sikora; Utz H Ermel; Anna Seybold; Michael Kunz; Giulia Calloni; Julian Reitz; R Martin Vabulas; Gerhard Hummer; Achilleas S Frangakis
Journal:  Proc Natl Acad Sci U S A       Date:  2020-10-16       Impact factor: 11.205

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.